.

450/750V LSZH Sheathed (2-4cores)

450/750V LSZH Sheathed (2-4cores) Application:The cables are mainly used in power stations,Website:, mass transit underground passenger systems, airports, petrochemical plants, hotels, hospitals, and high-rise buildings.Standard:Basic design to BS 7211; IEC 60502-1FIRE PERFORMANCEFlame Retardance (Single Vertical Wire Test)EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE *Reduced Fire Propagation (Vertically-mounted bundled wires & cable test)EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE Halogen FreeIEC 60754-1; EN 50267-2-1; DIN VDE ; CEI 20-37/2-1 ; BS 6425-1*No Corrosive Gas EmissionIEC 60754-2; EN 50267-2-2; DIN VDE ; CEI 20-37/2-2 ; BS 6425-2*minimum Smoke EmissionIEC 61034-1&2; EN 61034 -1&2; DIN VDE &2; CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2*No Toxic gasesNES 02-713; NF C 20-454Note: Asterisk * denotes superseded standard.VOLTAGE RATING450/750VCABLE CONSTRUCTION Conductor: Plain annealed copper wire, stranded according to IEC(EN) 60228 class 2.Insulation: Extruded cross-linked XLPE compound.Filler, binder (if any): PP, PETOuter Sheath: Thermoplastic LSZHcompound type LTS3 as per BS 7655-6.1 (Thermosetting LSZH compound type SW2-SW4 as per BS 7655-2.6 can be offered.)COLOUR CODEInsulation colour as per bs7671with earth conductorwithout earth conductor2Cores-Brown,Blue3CoresYellow/Green,Brown,BlueBrown,Gray,Black4CoresYellow/Green,Brown,Gray,BlackBrown,Gray,Black,Blue5CoresYellow/Green,Brown,Gray,Black,BlueBrown,Gray,Black,Blue,Blackabove 5 CoresYellow/Green,Black NumberedBlack Numberedsheath colour: BlackPhysical AND THERMAL PROPERTIESTemperature range during operation: Max.90°C for XLPE250°C in short-circuit for 5s max.Minimum bending radius: 6 x Overall DiameterCONSTRUCTION PARAMETERSConductorNo. of Core X Cross SectionNo./ Nominal Diameter Of StrandsNominal Overall Diameter ConductorNominal Insulation ThicknessNominal Sheath ThicknessNominal Overall DiameterMax.Dc Resistance Of Conductor WeightNoxmm2No./mmmmmmmmmmΩ/kmkg/km2x1.07/0.441.320.71.28.518.11012x1.57/0.531.590.71.29.112.11202x2.57/0.672.010.71.210.07.411542x4.07/0.852.550.71.311.14.612053x1.07/0.441.320.71.29.018.11183x1.57/0.531.590.71.29.612.11423x2.57/0.672.010.71.210.67.411853x4.07/0.852.550.71.311.84.612514x1.07/0.441.320.71.29.818.11414x1.57/0.531.590.71.210.512.11714x2.57/0.672.010.71.311.67.412264x4.07/0.852.550.71.313.04.61309Electrical PROPERTIES Conductor Operating Temperature : 90°CAmbient Temperature : 30°CCurrent-Carrying Capacities (Amp)Conductor crosssectional areaReference Method 4 (enclosed in conduit in thermally insulating wall etc)Reference Method 3 (enclosed in conduit on a wall or in trunking etc)Reference Method 1 (clipped direct)Reference Method 11 (on a perforated cable tray, horizontal or vertical)Reference Method 12 (free air)Horizontal flat spacedVertical flat spacedTrefoil2 cables, single- phase a.c. or d.c.3 or 4 cables, 3-phase a.c.2 cables, single- phase a.c. or d.c3 or 4 cables, 3-phase a.c.2 cables, single- phase a.c. or d.c. flat and touching3 or 4 cables, 3-phase a.c. flat and touching or trefoil2 cables, single- phase a.c. or d.c. or flat and touching3 or 4 cables, 3-phase a.c. flat and touching or trefoil2 cables, single- phase a.c. or d.c. or 3 c ables three phase2 cables, single- phase a.c. or d.c. or 3 cables three phase3 cables, trefoil 3-phase a.c.mm2AAAAAAAAAAA1..Voltage Drop (Per Amp Per Meter)Nominal Cross Section Area2 cables d.c.2 cables, single-phase a.c.3 or 4 cables, 3-phase a.c.Ref. Methods 3 and 4 (enclosed in conduit etc, in or on a wall)Ref. Methods 1 and 11 (clipped direct or on trays touching)Ref. Methods 3 and 4 (enclosed in conduit etc, in or on a wall)Ref. Methods 1, 11 and 12 (in trefoil)Ref. Methods 1 and 11(Flat and touching)1234567mm2mV/A/mmV/A/mmV/A/mmV/A/mmV/A/mmV/A/m1..


Send product request

To: UNIVERSAL CABLES LIMITED
Your E-mail:
Message text:


Send to other suppliers

Other supplier products

Type 209 1.1 To 11KV To AS/NZS 1802
Type 209 1.1 To 11KV To AS/NZS 1802 Type 209 1.1 to 11KV to AS/NZS 1802ApplicationsType 209 series cable is mainly used as a flexible feeder to machinery,Website:, more suitable as a ...
Belden9773
Belden9773 Multipair Individually Screened Cables-Belden Equivalent 9773,Website:, UL2919ApplicationsThese cables have individually screened pairs laid up. Ea...
Belden8336
Belden8336 Multipair Overall Foil & Braid Screened Cables-Belden Equivalent 8336ApplicationsThese cables have pairs laid up in a foil/braid screen. These cabl...
Fire Resistant UTP CAT5 Data Cables
Fire Resistant UTP CAT5 Data Cables Fire Resistant UTP CAT5 Data Cables FR-CAT5UTP4P24Application:The cables are desgined for structure wiring,Website:, compatible with all known conn...
450/750V LSZH Sheathed, Screened (multicore)
450/750V LSZH Sheathed, Screened (multicore) 450/750V LSZH Sheathed,Website:, Screened (multicore) Application:The cables are mainly used in power stations, mass transit underground passenger ...
All supplier products

Same products

PMMA VR Lens For Google Cardboard
PMMA VR Lens For Google Cardboard Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd PMMA VR Lens For Google Cardboard,Double Convex Lens
PMMA Double Convex Lens
PMMA Double Convex Lens Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd PMMA Double Convex Lens,Double Convex Lens
6X21 PBinoculars
6X21 PBinoculars Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd 6X21 PBinoculars,Porro Prism Binoculars
Night Vision Binoculars
Night Vision Binoculars Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd Night Vision Binoculars,Porro Prism Binoculars
10X25 High Power Binoculars
10X25 High Power Binoculars Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd 10X25 High Power Binoculars,Binoculars & Scopes