XLPE Insulated 6.35/11KV & 12.7/22KV AS/NZS 1972/1125/3808

XLPE Insulated 6.35/11KV & 12.7/22KV AS/NZS 1972/1125/3808ApplicationsThese cables are used as HV feeder cables in fixed conditions.StandardsAS/NZS 1972:2006AS/NZS 1125AS/NZS 3808ConstructionConductorsStranded plain copper conductor.InsulationXLPE.Individual Screen (earth conductor)Copper wire.Inner SheathPVC sheath.ArmourGalvanized steel wire armour.Outer SheathPVC sheath to AS/NZS 1429.1.Dimensions and WeightNominal Conductor AreaNominal Conductor DiameterInsulation ThicknessCore screenArmour Wire DiameterNominal Sheath ThicknessNominal Overall DiameterNominal WeightStrand SizeAreaof Screenmm2mmmmmmmm2mmmmmmkg/100m6.35/11kV164.83.410/0.855.72.002.446.6330255.83.410/0.855.72.502.550.1415356.83.411/0.856.22.502.652.8475508.03.415/0.858.52.502.755.7540709.63.421/0.8511.92.502.859.66459511.53.429/0.8516.52.502.963.977512013.13.436/0.8520.42.503.167.990515014.53.444/0.8525.02.503.271.5103018516.13.422/1.3531.53.153.378.6128024018.53.429/1.3541.53.153.584.7155030020.73.437/1.3553.03.153.790.4182040023.63.447/1.3567.33.154.097.9223012.7/22kV356.85.514/0.857.92.52.963.2600508.05.515/0.858.52.53.066.0665709.65.521/0.8511.92.53.169.97759511.55.529/0.8516.52.53.374.492012013.15.536/0.8520.43.153.479.5114015014.55.544/0.8525.03.153.583.1128018516.15.522/1.3531.53.153.789.1145024018.55.529/1.3541.53.153.995.0172030020.75.537/1.3553.03.154.1101.1201040023.65.547/1.3567.33.154.3108.22420
Website:
Other supplier products
|
|
150/250V HF-EPR Insulated, SW2/SW4 Sheathed, Collectively Screened Unarmoured Flame Retardant Instrumentation Control Cables |
150/250V HF-EPR Insulated,Website:, SW2/SW4 Sheathed, Collectively Screened Unarmoured Flame Retardant Instrumentation & Control CablesApplication:... |
|
|
Flame Retardant CAT6 CWB/SWB/SWA Armoured Data Cables PVC Sheath |
Flame Retardant CAT6 CWB/SWB/SWA Armoured Data Cables CAT6 U/UTP4P23CAT6 F/UTP4P23CAT6 SF/FTP4P23Application:Cat6 Cable is a cable standard for Gig... |
|
|
P3 Or P3/P10 RFOU/TFOU 6/10KV NEK606 Cable |
P3 or P3/P10 RFOU/TFOU 6/10KV NEK606 MV CableApplicationsThese cables are flame retardant,Website:, low smoke, halogen free and mud resistant, used... |
|
|
Belden8340 |
Multipair Overall Foil & Braid Screened Cables-Belden Equivalent 8340ApplicationsThese cables have pairs laid up in a foil/braid screen. These cabl... |
|
|
3.6 6kV 6 10kV 8.7 15kV IEC60092 SHF2 Sheathed MV Cable |
3.6/6kV,Website:, 6/10kV, 8.7/15kV XLPE Insulated, LSOH (SHF1)Sheathed, Armoured Flame Retardant MV Power Cables (SHF1 Inner Sheath)ApplicationThes... |
All supplier products
Same products
|
|
PMMA VR Lens For Google Cardboard |
Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd |
PMMA VR Lens For Google Cardboard,Double Convex Lens |
|
|
PMMA Double Convex Lens |
Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd |
PMMA Double Convex Lens,Double Convex Lens |
|
|
6X21 PBinoculars |
Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd |
6X21 PBinoculars,Porro Prism Binoculars |
|
|
Night Vision Binoculars |
Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd |
Night Vision Binoculars,Porro Prism Binoculars |
|
|
10X25 High Power Binoculars |
Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd |
10X25 High Power Binoculars,Binoculars & Scopes |