PE Insulated, LSZH Sheathed, Overall Screened And Armoured Instrumentation Cables (Single Triple)

PE Insulated,Website:, LSZH Sheathed, Overall Screened & Armoured Instrumentation Cables (Single Triple)RE-2Y(St)HSWAH 70°C / 300 VSTANDARDSBasic design to EN50288-7APPLICATION:These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petr°Chemistry industry plants, power plants, natural gas and petroluem plants, etc...These cables are used in the environments which have no corrosive gases are emitted in the event of fire. In case of fire, these cables inhibit the propagation of the flames whereby the development of smoke is extremely low. Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. These cables are not recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits.FIRE PERFORMANCEFlame Retardance (Single Vertical Wire Test)EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE 0482-332-1; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2);CEI 20-35/1-2; EN 50265-2-1*; DIN VDE *Reduced Fire Propagation (Vertically-mounted bundled wires & cable test)EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE Halogen FreeIEC 60754-1; EN 50267-2-1; DIN VDE ;CEI 20-37/2-1 ; BS 6425-1*No Corrosive Gas EmissionIEC 60754-2; EN 50267-2-2; DIN VDE ;CEI 20-37/2-2 ; BS 6425-2*Minimum Smoke EmissionIEC 61034-1&2; EN 61034 -1&2; DIN VDE &2;CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2*No Toxic gasesNES 02-713; NF C 20-454Sunlight ResistanceUL 1581 section 1200Oil ResistanceICEA S-73-532**Note: Asterisk * denotes superseded standard, **Test temperature +60°C, duration 4h. Retention: min 60% of tensite strength/min. 60% of elongation.VOLTAGE RATING300VCABLE CONSTRUCTIONConductor:Annealed copper solid or plain copper stranded to IEC 60228 Class 2.Insulation:PE compound, EN 50290. 2-23.Pair:Two conductors twisted to form a pairLay-up:Pairs laid up in layers of optimum pitchSeparator:Polyester tapeOverall Screen:Aluminium/polyester tape with tinned copper drain wire, 0.5mm2Inner sheath:LSZH compound, EN 50290-2-27Armour:Galvenized round steel wire, EN 10257-1Outer Sheath:Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZH compound type SW2-SW4 as per BS 7655-2.6 can be offered.). UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be offered as option.COLOUR CODEInsulation:Black / White / Red, continuously numbered on white core(1, 2..)for multitriples.Outer Sheath:Black or blue for intrinsically safe systemsPhysical AND THERMAL PROPERTIESTemperature Range During Operation (Fixed State):-30°C – +70°CTemperature Range During Installation (Mobile State):-5°C – +50°CMinimum Bending Radius:10 X Overall DiameterCONSTRUCTION PARAMETERSCable CodeRE-2Y(St)HSWAHNo. of Triplesx3xCross SectionNominalInsulationThick-nessNominalInnerSheathThick-nessNominal OverallDiameterOverInnerSheathNominalArmourWireDiameterNominalOuterSheathThick-nessNominal Overall DiameterApprox.WeightNo.x3xmm2mmmmmmmmmmmmkg/kmRE-2Y(St)HSWAH 1T0.51x3x0.500.350.85.40.91.39.8200RE-2Y(St)HSWAH 1T0.751x3x0.750.380.96.10.91.310.5220RE-2Y(St)HSWAH 1T1.01x3x1.00.40.96.60.91.311.0244RE-2Y(St)HSWAH 1T1.31x3x1.30.450.97.20.91.311.6268RE-2Y(St)HSWAH 1T1.51x3x1.50.450.97.50.91.311.9277Note : Other conductor sizes & core configurations are available upon requestElectrical PROPERTIESConductor Area Sizemm 20.50.751.01.31.5Insulation thickness (nominal)mm0.350.380.40.450.45Conductor resistance (20°C)Ω/km36.72518.514.212.3Insulation resistance (20°C)MΩ.km(Min.)5000Mutual Capacitance (1 kHz)pF/m(Max.)115Capacitance unbalance(1 kHz)pF/500 m (Max.)500L / R (ratio) (max.)μH/Ω2525254040InductancemH/km(Max.)11111Operating voltage UrmsV300Test VoltageCore to CoreV1500Core to ScreenV1500

Send product request

To: UNIVERSAL CABLES LIMITED
Your E-mail:
Message text:


Send to other suppliers

Other supplier products

Three Core Cables To BS 6622
Three Core Cables To BS 6622 Three Core Medium Power Cable to BS 6622 Application: ...
H05G-U/H07G-U/R
H05G-U/H07G-U/R German Standard Industrial Cables H05G-U/H07G-U/RApplication and DescriptionThese cables are recommended for the internal wiring of switchboards an...
F5 QFCB NEK606 Cable
F5 QFCB NEK606 Cable F5 QFCB armoured & fire resistant optical fibre cables NEK606Applications :These steel armoured optical fibre cables are flame retardant,Website:, ...
Fire Resistant RS485 Databus Cables
Fire Resistant RS485 Databus Cables Fire Resistant RS485 Databus Cables Application:The cables are designed for RS485 data connections where continued functionality is required during...
H07RN8-F
H07RN8-F VDE Standard Industrial Cables H07RN8-FApplication and DescriptionThese cables particularly for use in fresh water up to 10 m depth with a maximum ...
All supplier products

Same products

PMMA VR Lens For Google Cardboard
PMMA VR Lens For Google Cardboard Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd PMMA VR Lens For Google Cardboard,Double Convex Lens
PMMA Double Convex Lens
PMMA Double Convex Lens Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd PMMA Double Convex Lens,Double Convex Lens
6X21 PBinoculars
6X21 PBinoculars Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd 6X21 PBinoculars,Porro Prism Binoculars
Night Vision Binoculars
Night Vision Binoculars Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd Night Vision Binoculars,Porro Prism Binoculars
10X25 High Power Binoculars
10X25 High Power Binoculars Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd 10X25 High Power Binoculars,Binoculars & Scopes