PE Insulated, LSZH Sheathed And Overall Screened Instrumentation Cables (Multitriple)

PE Insulated,Website:, LSZH Sheathed & Overall Screened Instrumentation Cables (Single Triple)RE-2Y(St)H 90°C / 300 VSTANDARDSBasic design to EN50288-7APPLICATION:These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... These cables are used in the environments which have no corrosive gases are emitted in the event of fire. In case of fire, these cables inhibit the propagation of the flames whereby the development of smoke is extremely low. Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply.With blue sheath it is suitable for intrinsically safe systems. These cables are not recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits.FIRE PERFORMANCEFlame Retardance (Single Vertical Wire Test)EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE 0482-332-1; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2);CEI 20-35/1-2; EN 50265-2-1*; DIN VDE *Reduced Fire Propagation (Vertically-mounted bundled wires & cable test)EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE Halogen FreeIEC 60754-1; EN 50267-2-1; DIN VDE ;CEI 20-37/2-1 ; BS 6425-1*No Corrosive Gas EmissionIEC 60754-2; EN 50267-2-2; DIN VDE ;CEI 20-37/2-2 ; BS 6425-2*Minimum Smoke EmissionIEC 61034-1&2; EN 61034 -1&2; DIN VDE &2;CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2*No Toxic gasesNES 02-713; NF C 20-454Sunlight ResistanceUL 1581 section 1200Oil ResistanceICEA S-73-532**Note: Asterisk * denotes superseded standard, **Test temperature +60°C, duration 4h. Retention: min 60% of tensite strength/min. 60% of elongation.VOLTAGE RATING300VCABLE CONSTRUCTIONConductor:Annealed copper solid or plain copper stranded to IEC 60228 Class 2.Insulation:PE compound, EN 50290. 2-23.Triple:Three conductors twisted to form a tripleLay-up:Triples laid up in layers of optimum pitchSeparator:Polyester tapeOverall Screen:Aluminium/polyester tape with tinned copper drain wire, 0.5mm2Outer Sheath:Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZH compound type SW2-SW4 as per BS 7655-2.6 can be offered.). UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be offered as option.COLOUR CODEInsulation:Black / White / Red, continuously numbered on white core(1, 2..)for multitriples.Outer Sheath:Black or Blue for intrinsically safe systemsPhysical AND THERMAL PROPERTIESTemperature Range During Operation (Fixed State):-30°C – +90°CTemperature Range During Installation (Mobile State):-5°C – +50°CMinimum Bending Radius:7.5 X Overall DiameterCONSTRUCTION PARAMETERSCable CodeRE-2Y(St)HNo. of Triplesx3xCross SectionNominalInsulationThicknessNominalOuter SheathThicknessNominalOverallDiameterApprox.WeightNo.x3xmm²mmmmmmkg/kmRE-2Y(St)H 1T0.51x3x0,500.350.85.449RE-2Y(St)H 1T0.751x3x0,750.380.96.160RE-2Y(St)H 1T1.01x3x1.00.40.96.671RE-2Y(St)H 1T1.31x3x1,30.450.97.286RE-2Y(St)H 1T1.51x3x1,50.450.97.597Note : Other conductor sizes & core configurations are available upon requestElectrical PROPERTIESConductor Area Sizemm²0.50.751.01.31.5Insulation thickness (nominal)mm0.350.380.40.450.45Conductor resistance (20°C)Ω/km36.725.018.514.212.3Insulation resistance (20°C)MΩ.km(Min.Mutual Capacitance (1 kHz)pF/m(Max.Capacitance unbalance(1 kHz)pF/500 m (Max.)00000InductancemH/km(Max.)11111L / R (ratio) (max.)μH/Ω2525254040Operating voltageV300Test Voltage UrmsCore to CoreVCore to ScreenV
Other supplier products
|
|
Type SHD-GC Three-Conductor Round Portable Power Cable, TPU Jacket 5kV ICEA S-75-381 |
Type SHD-GC Three-Conductor Round Portable Power Cable,Website:, TPU Jacket 5kV ICEA S-75-381ApplicationsThese heavy duty cables are designed for h... |
|
|
[FA-] TTYS, TTYCS, TTYCYS [FA-] TTPYS, TTPYCS, TTPYCYS |
250V [FA-] TTYS,Website:, TTYCS, TTYCYS [FA-] TTPYS, TTPYCS, TTPYCYSStandards:JISC 3410-1999IEC 60332-1IEC 60332-3 Cat.A(for FA-type)CABLE CONSTRUC... |
|
|
Belden9842 |
Multipair Overall Foil & Braid Screened Cables-Belden Equivalent 9842ApplicationsThese cables have pairs laid up in a foil/braid screen,Website:, s... |
|
|
(N)TSCGEWOEU Medium-Voltage Fixed Installation Cable With Fiber Optics |
(N)TSCGEWOEU Medium-Voltage Fixed Installation Cable With Fiber OpticsApplicationsThese cables are used for For laying alongside the conveyor belts... |
|
|
NTSWOEU 0.6/1kV E-Loader Cable VDE 0250 Part 813 |
NTSWOEU 0.6/1kV E-Loader Cable VDE 0250 Part 813ApplicationsThese cables are used for the connection of mobile machines under extremelyhigh mechani... |
All supplier products
Same products
|
|
PMMA VR Lens For Google Cardboard |
Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd |
PMMA VR Lens For Google Cardboard,Double Convex Lens |
|
|
PMMA Double Convex Lens |
Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd |
PMMA Double Convex Lens,Double Convex Lens |
|
|
6X21 PBinoculars |
Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd |
6X21 PBinoculars,Porro Prism Binoculars |
|
|
Night Vision Binoculars |
Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd |
Night Vision Binoculars,Porro Prism Binoculars |
|
|
10X25 High Power Binoculars |
Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd |
10X25 High Power Binoculars,Binoculars & Scopes |