THHN/THWN, 600V, Type TC Control Cable

UL Industrial Cables THHN/THWN,Website:, 600V, Type TC control Cable Application and DescriptionType TC Control Cable is for use in industrial power or control circuits where small diameter, flame retardant cables are desired. Primary installations include cable trays, raceways, and outdoor locations where supported by a messenger wire. Type TC is also listed for direct burial and for use in Class 1, Division 2 hazardous locations and Class 1 control circuits. Constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10. Conductors may be used at temperatures not to exceed 75°C in wet locations or 90°C in dry locations. 130°C for emergency overload ratings, and 250°C for short circuit ratings. Not recommended in D.C. operation in wet locations.Cable ConstructionConductorSoft annealed bare copper, Class B stranding per ASTM B8InsulationPolyvinyl chloride (PVC) insulation over witd a nylon (polyamide) jacket appliedAssemblyThree or more conductors will be cabled round witd fillers and a nylon rip cord is put under tde jacket for ease of strippingJacketHeat retardant, moisture and sunlight resistant PVCColorupon request, black is preferableTechnical Compliances- NFPA 70 (NEC)- UL 1581 - Electrical Wires, Cables and Flexible Cords- ICEA S-58-679 - Control Cable Conductor Identification Metdod 1, Table 2- UL 1685 - UL Flame Exposure Test (70,000 Btu/hr)Cable ParameterInsulation tdickness: 16-12AWG PVC 15mils(0.38mm) Nylon 4mils(0.10mm)10AWG PVC 20mils(0.50mm) Nylon 4mils(0.10mm)AWG 16 (26 STRANDS) - TYPE TC-TFFN* CONDUCTORSNUMBER OFCONDUCTORSNOMINAL JACKET THICKNESS INCH/MMNOMINAL OVERALL DIAMETER INCH/MMCABLE WEIGHTLBS/KFT KG/KM20.0451.140.2887.32436430.0451.140.3037.70537940.0451.140.3298.36669850.0451.140.3579.078112070.0451.140.3869.8010315390.0451.140.44711..0451.140.50112..0601.520.58514..0601.520.61415..0601.520.71318..0802.030.75319..0802.030.81220.62477709AWG 14 (7 strands) - Type TC-THHN or THWN ConductorsNUMBER OFCONDUCTORSNOMINAL JACKET THICKNESS INCH/MMNOMINAL OVERALL DIAMETER INCH/MMCABLE WEIGHTLBS/KFT KG/KM20.0451.140.3057.8568330.0451.140.3228.27411040.0451.140.3508.99313950.0451.140.3819.710916260.0451.140.41310.512919270.0451.140.41310.514521580.0451.140.44611.316424390.0451.140.47812.2182271100.0601.520.55014.0217322120.0601.520.56814.4251373150.0601.520.62715.9305454190.0601.520.65816.7373555200.0601.520.69117.6393584250.0601.520.76619.4483719300.0601.520.81020.6568845370.0802.030.91323.27201072AWG 12 (7 STRANDS) - TYPE TC-THHN OR THWN CONDUCTORSNUMBER OFCONDUCTORSNOMINAL JACKET THICKNESS INCH/MMNOMINAL OVERALL DIAMETER INCH/MMCABLE WEIGHTLBS/KFT KG/KM20.0451.140.3408.67511230.0451.140.3609.210515640.0451.140.39210.012819050.0451.140.42810.915422960.0451.140.46611.818327270.0451.140.46611.820730880.0451.140.50412.823434990.0601.520.57214.5277412100.0601.520.62115.8307457120.0601.520.64116.3358532150.0601.520.71018.0438652190.0601.520.74618.9539802200.0601.520.78519.9568845250.0802.030.91123..0802.030.96324..0802.031.03626.310441553AWG 10 (7 STRANDS) TYPE TC-THHN OR THWN CONDUCTORSNUMBER OFCONDUCTORSNOMINAL JACKET THICKNESS INCH/MMNOMINAL OVERALL DIAMETER INCH/MMCABLE WEIGHTLBS/KFT KG/KM20.0451.140.40710.311116630.0451.140.43311.015523040.0451.140.47312.019829450.0601.520.54913.925037160.0601.520.59615.129443770.0601.520.59615.133349580.0601.520.64516.437756190.0601.520.69317.6421626100.0601.520.75519.2467694120.0601.520.78019.8547814150.0802.030.90823..0802.030.95424..0802.031.00325..0802.031.11228..0802.031.17729..0802.031.27132.316142402
Other supplier products
|
|
Fire Resistant RG59 B/U Coaxial Cables |
Fire resistant RG59 B/U Coaxial cables RG59 B/U FRApplication:The cables are designed for CCTV,Website:, security, smoke detection and evacuation m... |
|
|
Belden9844 |
Multipair Overall Foil & Braid Screened Cables-Belden Equivalent 9844ApplicationsThese cables have pairs laid up in a foil/braid screen,Website:, s... |
|
|
RHH/RHW-2, 600V |
UL Industrial Cables RHH/RHW-2,Website:, 600V, Power Cable, CT RatedApplication and DescriptionType RHH or RHW-2 or USE-2 conductors are for use in... |
|
|
(H)03Z1Z1-F/(H)05Z1Z1-F |
VDE Standard Industrial Cables (H)03Z1Z1-F/(H)05Z1Z1-FApplication and DescriptionThese cables may be used when halogen-free,Website:, low smoke and... |
|
|
Cat 6 U/FTP 23AWG |
CAT 6 U/FTP 23AWG IEC60092ApplicationThese Cat6 U/FTP cables are manufactured in accordance with IEC 61156-5 requirements,Website:, can support all... |
All supplier products
Same products
|
|
PMMA VR Lens For Google Cardboard |
Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd |
PMMA VR Lens For Google Cardboard,Double Convex Lens |
|
|
PMMA Double Convex Lens |
Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd |
PMMA Double Convex Lens,Double Convex Lens |
|
|
6X21 PBinoculars |
Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd |
6X21 PBinoculars,Porro Prism Binoculars |
|
|
Night Vision Binoculars |
Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd |
Night Vision Binoculars,Porro Prism Binoculars |
|
|
10X25 High Power Binoculars |
Seller: Jinhua Kaiyue Photoelectric Technology Co.,Ltd |
10X25 High Power Binoculars,Binoculars & Scopes |