Lab combined environmental test chamber with shaker
Whats/App: +86 156 1874 6768
Web: standard-groups.com
Applications
Aerospace Sector: Evaluates the performance of aircraft components under temperature, humidity, and vibration conditions.
Electronics and Communications Industry: Conducts comprehensive testing on electronic components and communication equipment to assess their reliability in diverse environments.
Materials Science: Assists researchers in investigating changes in the physical and chemical properties of materials under varying environmental conditions, providing data support for new material development.
Automotive Manufacturing: Simulates the environmental conditions automotive components encounter in diverse climates and road conditions to evaluate their durability and reliability.
Standards
GB/T 2423.35 Procedures for combined temperature, humidity, and vibration testing, including environmental condition setting and performance monitoring
GB/T 28046.3 Focuses on automotive electrical and electronic systems, classifying severity by component installation location (e.g., engine, body) to simulate actual operating environments
GB/T 44279-2024 Covers combined temperature-humidity-vibration-low-pressure testing, enhancing simulation capabilities for extreme environments (e.g., high altitude or tropical climates)
IEC 60068-2-53 Test methods for electrical and electronic products under combined temperature, humidity, and vibration environments, emphasizing accelerated exposure of product failure modes through multi-stress superposition
ISO 16750-3 Prescribes coordinated testing of mechanical loads (vibration) and temperature conditions for automotive electronic equipment, ensuring component durability during vehicle operation
Features
1. Simultaneously simulate multiple environmental factors: Capable of concurrently simulating temperature, humidity, and vibration to more closely replicate actual product usage conditions, enhancing test accuracy.
2. Accelerates exposure of potential product defects: Through stress superposition, it expedites the manifestation of latent design flaws, manufacturing imperfections, or premature component failures, providing evidence for design enhancements.
3. Cost savings: Reduces equipment investment and testing space requirements, thereby lowering R&D and testing expenses.
Parameters
| Item | Specification |
|---|---|
| Temperature Range | -60°C ~ +150°C |
| Temperature Change Rate | ≥5°C/min (with load), average over the range of -40°C to 100°C |
| Temperature Deviation | ≤±2°C (no load, steady state) |
| Temperature Uniformity | ≤2°C (no load, steady state) |
| Temperature Fluctuation | ≤±0.5°C (no load, steady state) |
| Humidity Range | 20% R.H. ~ 98% R.H. |
| Humidity Deviation | +2% R.H. ~ -3% R.H. (when >75% R.H.), ±5% R.H. (when ≤75% R.H.) |
Accessories
(1) Removable Floor Panels: Customized interface plates to match different shaker head expanders.
(2) Flexible Thermal Bellows: High-temperature silicone or reinforced fabric sleeves to seal the shaker-to-chamber connection.
(3) Multi-Channel Accelerometers: For real-time monitoring of vibration response at different points on the specimen.
(4) Cable Access Ports: Standard 100mm or 150mm ports for power and signal lines to the device under test (DUT).
(5) CCTV Monitoring: High-definition internal camera system to record specimen behavior during high-intensity vibration.
Send product request
Other supplier products
| Dry Sand Rubber Wheel Wear Tester | Standard ASTM G65 JBT_7705 Applicable standards Dry and wet abrasive wear testing machines usually need to follow certain standards and specifi... | |
| Drawer slide durability testing machine | The Drawer Slide Durability Testing Machine is designed to evaluate the mechanical durability, operational reliability, and service life of drawer ... | |
| Surface Scratch Resistance Testing Machine | Whats/App: +86 156 1874 6768 Web: standard-groups.com Application Primary test objects Accessible solid insulating parts of household appliance... | |
| Femoral Stem Fatigue Performance Testing Machine | Standard YY/T 0809.4 (China): Specifies fatigue testing protocols for femoral stems in partial/total hip arthroplasty. ISO 7206-4 (International)... | |
| Thermal - Cold Cycle Machine | Standard BS 7291: Compliant for thermal cycling tests on thermoplastic pipe systems (1769 Series with pressure chamber). Adaptive Certification... |
Same products
| Walk-in Environmental Constant Temperature and Humidity Test Chamber | Seller: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards GB/T2423.3 Environmental Testi... | |
| High reliability walk-in heat aging chamber | Seller: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications Walk-in High-Temperature Ag... | |
| Fully programmable walk-in climate simulation system | Seller: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications High and Low Temperature Hu... | |
| PV Degradation Testing Chamber | Seller: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications The Light Decay Test Chambe... | |
| PV module acid corrosion test equipment supplier | Seller: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications The Photovoltaic Acid Mist ... |