Carpet Flammability Tester
Standards:
BS 4790, ISO 6925, BS 6307
Applications:
The Flammability Tester is used to test the effects of a small source of ignition on floor coverings. It can be used for either the hot metal nut test (BS 4790) or the methenamine tablet test (ISO 6925 and BS 6307).
Product Information:
The test chamber is manufactured from non-combustible heat resistant board with a counter weighted sliding panel for easy access. The mirror on top of the chamber allows the operator to view the specimens during the test.
Features:
1. Complete with measuring grid and clamping ring;
2. Sliding panel for easy access;
3. Angled mirror for viewing;
4. Applicable to 2 different tests, enclosed unit for optimum;
5. Safety.
Test Method:
The stainless steel nut is heated to a temperature of 900°C in a muffle furnace. The specimen is placed inside the test chamber and the clamping rig is placed onto the sample using crucible tongs supplied. The heated nut is placed in the centre of the clamping rig. After 30 seconds the nuts removed and the effects of the ignition allowed to subside. Measurements are then made to assess the spread of the ignition on the sample. It is recommended that the test chamber is placed in a laboratory fume hood. The conditioned specimens are placed on the removable base inside the test chamber and the metal plate with a circular cut-out is placed on the sample. The tablet is placed at the centre of the specimen and ignited. After the flame has extinguished, measurements are taken to assess the effects.
Consumables:
- Test Chamber(includes furnace)
- Accessories for Hot Nut Test
- Accessories for Methanamine Tablet Test
- M16 Nut for Hot Nut Test
- Methylamine Tablets for Methylamine Tablets Test
product display
Other supplier products
|
Filter Media Tester HMT 1000 |
Heatable modular test system for oil mist separators in accordance with ISO 20654 Quality assurance and the development of filters/separators/traps... |
|
Automatic Wrinkle Recovery Tester |
The main principle of the wrinkle recovery tester is to apply a predetermined pressure to the specimen under standard atmospheric conditions and to... |
|
Cone calorimetric test equipment |
StandardsApplication
ISO 5660Reaction to fire tests-Heat release, smoke production and mass loss rate.ASTM E 1354Method of test for heat and smo... |
|
Velcro Fatigue Tester and velcro fatigue testing machines |
Velcro Fatigue Testeris designed for opening and closing the hook and loop fasteners, A hook and loop fastener is repeatedly opened and closed for ... |
|
45 degree flammability tester |
Testing Standards:ASTM D1230, FTMS 191-5908, CFR 16 Part 1610, CALIF TB 117, NFPA 702, GB/T 14644Applications:45 degree flammability tester is desi... |
All supplier products
Same products