Filter Membrane Pore Analysis Tester
Get a quote:
Whats/App: +86 185 0176 3615
Web: qinsun-lab.com
The Filter Membrane Pore Analysis Tester is a precision instrument designed to measure the pore size, distribution, and integrity of flat filter membranes. Utilizing the principle of capillary flow porometry, the tester provides quantitative data on bubble point, mean flow pore size, and full pore size distribution. This information is critical for evaluating filtration efficiency, flow rate, and retention performance of membranes used in microfiltration, ultrafiltration, and sterile filtration applications.
Application
(1) Determining pore size distribution, bubble point, and mean flow pore size of flat filter membranes.
(2) Quality control in the production of filtration membranes to ensure consistency and compliance with specifications.
(3) Research and development of new membrane materials and designs.
(4) Characterization of membranes for various filtration applications, including water purification, pharmaceutical, food & beverage, and chemical processes.
(5) Investigating performance issues in membranes, such as defects, irregular pore sizes, or compromised integrity.
(6) Validation of membrane integrity and performance for sterilization and critical filtration processes.
Standards
(1) ASTM E1294 — Standard Test Method for Pore Size Characteristics of Membranes by Bubble Point and Mean Flow Pore Test
(2) ASTM F316 — Standard Test Method for Pore Size Characteristics of Membrane Filters by Capillary Flow Porometry
(3) ISO 4003 — Determination of Pore Size and Bubble Point of Membranes
(4) ISO 15901-2 — Pore size distribution and porosity analysis of materials using capillary flow methods
(5) USP — Particulate Matter in Injections (relevance for sterile filtration membrane validation)
(6) EN 14683 — Medical face masks: bacterial filtration performance (membrane evaluation)
Technical Parameters
| Parameter | Specification |
|---|---|
| Pressure Range | 0–500 kPa (adjustable) |
| Pressure Resolution | 0.01 kPa |
| Gas Flow Range | 0–5000 mL/min |
| Flow Accuracy | ±1% FS |
| Bubble Point Measurement | Automatic detection of first gas flow through largest pore |
| Mean Flow Pore Size | Calculated from flow vs. pressure curve |
| Sample Size | Flat membrane: 10–100 mm diameter (custom holders available) |
| Temperature Monitoring | 0–50°C with ±0.5°C accuracy |
| Wetted Fluids | Water, alcohol, or other standard wetting liquids |
| Control System | PLC or microcontroller-based automatic operation |
| Data Output | PC software, USB, or Ethernet |
| Display | Real-time pressure, flow, and test status |
| Power Supply | AC 220V 50Hz |
Send product request
Other supplier products
| Film Heat Shrinkage Tester | Get a quote: Web: qinsun-lab.com Email:serving@qinsun-lab。com The film heat shrinkage rate tester is a device specifically designed to measure t... | |
| Nonwovens liquid loss tester - lab instrument | Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com Email: serving@qinsun-lab。com This fabric friction tester can measure the static ... | |
| 5kN Universal Testing Machine | Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com Email: serving@qinsun-lab。com This series of testing machines realizes the automa... | |
| Damp Freeze and Thermal Cycling Test Chamber | Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com The Damp Freeze and Thermal Cycling Test Chamber is suitable for: Damp-freeze and... | |
| Reciprocating Wear Tester | Testing Equipment | Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com ASTM Standards: Formulated by the American Society for Testing and Materials (ASTM... |