.

Toilet Corrosion Test Chamber (HCl and Ammonia),acid exposure cabinet for bathroom ware

The Toilet Corrosion Test Chamber (HCl and Ammonia) is used to evaluate the rust resistance of toilet products to detergents and urine, meeting the corrosion testing requirements of GB/T 4706.53-2024 and IEC 60335-2-84:2019 standards. This equipment simulates an ammonia and hydrochloric acid environment to conduct a 96-hour corrosion test on the toilet, ensuring its continued normal operation under harsh conditions. Key technical parameters include test chamber dimensions, temperature, and gas concentration, and it is equipped with appropriate safety and sealing measures.

Applications

Toilet seat hydrochloric acid and ammonia corrosion tester is used for testing to evaluate the ability of toilet seat products to provide adequate rust protection against detergents and urine. The test chamber by simulating ammonia components, hydrochloric acid solvent body, medium on the toilet electrical components or other inorganic cover layer in condensation conditions of corrosion test. The test chamber is electronic toilet sampling and testing of product quality supervision and inspection institute 3 testing organizations and toilet manufacturers of essential test equipment.

Standards

GB/T 4706.53-2024: Safety of household and similar electrical appliances - Part 2: Particular requirements for commercial dishwashing machines, glass-washing machines and utensil-washing machines

IEC 60335-2-84:2019: Household and similar electrical appliances - Safety - Part 2-84: Particular requirements for commercial dishwashing machines, glass-washing machines and utensil-washing machines

Features

1. Precise and Controllable Corrosive Environment: It can stably maintain specific concentrations of ammonia (0.055%±0.005%) and hydrochloric acid (0.0005%±0.0002%), using a gas cylinder method for gas generation and a corrosion-resistant mass flow meter for flow control, ensuring precise matching of the corrosive medium concentration and flow rate to test requirements.

2. Standardized Test Conditions: It requires operation in a cleanroom environment without strong airflow. Temperature (25℃±2℃) and humidity (<75% RH) are strictly controlled to ensure the repeatability and reliability of test results.

3. Strong Sample Load Capacity Adaptability: The equipped sample test rack has a maximum load capacity of ≥50kg and can maintain a vertical placement at 90°±2°, adapting to the fixing requirements of large items such as toilet seats.

4. Reasonable structural dimensions: The inner casing (W1200×H1200×D1200mm) is large enough to accommodate a toilet, while the outer casing (approximately W2350×H1700×D1500mm) balances operating space with equipment integration.

5. Low operating energy consumption: The installed power is only 400W, and it is compatible with AC 220V universal power supplies, resulting in high cost and environmental adaptability.

Technical Parameters

No.Main ParametersSpecifications
1 Inner box size W1200×H1200×D1200mm
2 Outer box size About W2350×H1700×D1500mm
3 Test temperature Room temperature
4 Ammonia concentration 0.055%±0.005
5 Hydrochloric acid concentration 0.0005%±0.0002
6 Test gas generation method Cylinder method
7 Test gas control Calculate by volume ratio (per test requirements), then control flow rate via anticorrosive mass flow meter
8 Sample test frame Maximum load ≥50kg; placed vertically at 90°±2°
9 Use environment & temperature Clean room (no strong airflow); temperature 25℃±2℃
10 Use environmental humidity <75% RH
11 Equipment power supply AC 220V 50/60Hz
12 Installed power 400W

Accessoriess

1. Hydrochloric acid and ammonia corrosion test chamber 1 set

2. A set of exhaust gas filtering device

3. ammonia gas cylinder 1 bottle

4. Matching special pressure reducing valve 1pc

5.1 bottle of hydrochloric acid

Test Procedures

The following tests shall be performed on the toilet samples, except where the electrical components are in a closed state or where they are unlikely to be exposed to the polluted environment.

Place the toilet sample in an indoor atmosphere with an ammonia gas volume fraction of (0.055 ± 0.005)% for 96 hours.

Then place the toilet sample in an indoor atmosphere with a hydrochloric acid volume fraction of (0.0005 ± 0.0002)% for 96 hours.

After the tests, the toilet sample should not exhibit any damage that would result in non-compliance with GB/T 4706.53-2024 or IEC 60335-2-84:2019 standards.


Send product request

To: Standard International Group (HK) Limited
Your E-mail:
Message text:


Send to other suppliers

Other supplier products

Catheter bending resistance tester
Catheter bending resistance tester The Catheter Bending Resistance Tester is a specialized instrument designed to evaluate the bending performance and flow characteristics of cathete...
Super Xenon Weather Meter
Super Xenon Weather Meter SX75 accelerates the degradation of materials by exposing them to simulated outdoor and indoor environments such as sunlight,temperature,humidity,r...
Closed - Space Tester for Aerosol Sprays
Closed - Space Tester for Aerosol Sprays Product Description Conforms to UN Recommendations on the Transportation of Dangerous Goods - Manual of Tests and Criteria 31.5 Confined Space Ign...
Coatings Shear
Coatings Shear Standard YY/T 0856-2011 (China): Specifies mechanical testing protocols for metal angular fixators, including single-compression bending and bendi...
Electrochemical Corrosion and Wear Testing Machine
Electrochemical Corrosion and Wear Testing Machine Electrochemical corrosion and wear testing machines are widely used in materials science, mechanical engineering, electronic engineering, aerospace...
All supplier products

Same products

Dynamic Shear Rheometer
Dynamic Shear Rheometer Seller: Standard Groups Dynamic Shear Rheometers are configured to meet the demands of everyday quality control testing o...
Noxious Gas Test Chamber
Noxious Gas Test Chamber Seller: Standard Groups Noxious gas tеst chambеrs play a crucial role in thе industrial sector by еnsuring thе longеvity ...
Chest Drainage Tester
Chest Drainage Tester Seller: Standard Groups The Chest Drainage Tester is a precision instrument designed to evaluate the performance of dispo...
Plastic Smoke Density Tester
Plastic Smoke Density Tester Seller: Standard Groups You can use the F313 Plastic Smoke Density Tester in the following areas: Plastics industry: Eva...
Washing Fastness testing machine
Washing Fastness testing machine Seller: Standard Groups G228B washing fastness tester is used for washing, dry-clean color fastness testing. Electric tou...