Adiabatic Accelerated Calorimeter,adiabatic calorimeter apparatus bulk order

Whats/App: +86 156 1874 6768

Web: standard-groups.com

An Accelerating Rate Calorimeter (ARC) is a high-precision thermal analysis instrument that assesses the thermal decomposition behavior and safety risks of chemical substances by monitoring sample temperature, pressure, and thermodynamic parameters in real time under adiabatic conditions.

Application

Battery Safety Research: Evaluating the thermal runaway characteristics of batteries under abusive conditions, providing key parameters of the thermal runaway process, such as self-heating onset temperature and thermal runaway initiation temperature.

Material Thermal Stability: Studying the thermal stability and thermal decomposition behavior of materials, and evaluating the thermal safety of materials.

Chemical Reaction Thermal Analysis: Analyzing the thermal effects of chemical reactions, providing thermodynamic parameters such as reaction heat and activation energy.

Safety Standard Development: Assisting in determining the safe operating range and runaway hazards of materials and products, providing references for the development of safety standards.

Standards

T/CIS 17007-2023:

Since "T/CIS" is not a widely - known, globally standardized prefix like some international or well - recognized national standard - setting body abbreviations, without specific context about the issuing organization (CIS here might refer to a certain industry association or similar entity in China), a general way to name it could be "Technical Specification T/CIS 17007 - 2023" (assuming it is a technical specification; if it's a different type of standard, the description before the number can be adjusted accordingly).

JJF 1059.1-2012:

Evaluation and Expression of Uncertainty in Measurement - Part 1: General Rules (JJF is the code for metrological verification regulations in China, and this standard is about the evaluation and expression of measurement uncertainty)

JJF 1001-2011:

General Terms in Metrology and Their Definitions (JJF 1001 is a fundamental standard in the field of metrology in China that defines general metrological terms)

Features

1. Supports Heating - Waiting - Scanning (HWS) mode, constant - temperature mode, isochronous scanning mode, etc. 2. Equipped with professional data - analysis software, enabling automatic calculation of parameters such as exothermic onset temperature, adiabatic temperature rise, activation energy, and pre - exponential factor.

3. The software integrates the safety risk assessment methods and standards for reactions in the *Guidelines for Safety Risk Assessment of Fine Chemical Reactions* issued by the former State Administration of Work Safety, enabling one - stop assessment of the hazard level of reaction processes.

4. Key components are from well - known international brands, ensuring the long - term and stable operation of the instrument.

5. After the experiment, an inert gas can be introduced to rapidly cool down the furnace body.

6. Features an experimental status indication function, as well as overpressure and over - temperature alarm functions.

7. The furnace cover has an automatic lifting function, ensuring safety and facilitating operation.

8. With professional industrial design, it is simple and elegant, has a user - friendly human - machine interaction, and is easy to learn, understand, and operate.

9. The data - analysis software incorporates the differential conversion - rate thermodynamics calculation method, which has significant advantages in the calculation of the thermal decomposition kinetics of mixed materials and the prediction of thermal hazards.

Parameters

Operating Environment

(5~40)℃, <85%RH

Temperature Control Range

Room temperature~500℃

Temperature Detection Threshold

(0.005~0.02)℃/min

Temperature Tracking Rate

(0.005~40)℃/min

Temperature Display Resolution

0.001℃

Pressure Range

Maximum withstand pressure 20MPa

Pressure Resolution

1kPa

Sample Cell Specifications

8mL

Sample Cell Material

Stainless steel, titanium, Hastelloy (optional)

Phi Value

≤1.35

Interfaces

USB or RJ45

Power Supply

AC220V/50Hz

Power

≤3000W

Dimensions

620mm*470mm *670mm

Weight

Approx. 78kg

Accessoriess

Core measurement system components

Temperature control and insulation system components

Sample handling system components

Safety and protection system components, etc.

Test Procedures

Preparation before operation: Operators should wear appropriate work clothes, gloves, and safety glasses, as well as other personal protective equipment. Operators must understand the working principle of the instrument, its operating procedures, and the corresponding experimental procedures.

Experimental operation: Operators must place the test substance, samples, and test tubes in the sample chamber of the adiabatic accelerating calorimeter according to the instructions or experimental requirements. The use of excessive reagents is prohibited during the experiment.

Experimental precautions: Touching the high-temperature samples inside the sample chamber during the experiment is prohibited. After the experiment is completed, the instrument power should be turned off, all connecting lines should be disconnected, and the adiabatic accelerating calorimeter should be properly cleaned for future use.

Data recording and analysis: By connecting to a computer or data logger, the instrument can display the temperature change curve during the reaction in real time.


Send product request

To: Standard International Group (HK) Limited
Your E-mail:
Message text:


Send to other suppliers

Other supplier products

Automatic Filter Integrity and Leak Tester ASTM International
Automatic Filter Integrity and Leak Tester ASTM International Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards (1) GB/T 15480.2 – Air tightness test under static pressure ...
Metal ring friction and wear testing machine
Metal ring friction and wear testing machine Whats/App: +86 156 1874 6768 Web: standard-groups.com Evaluate the wear resistance of the material: By simulating the friction process, real-tim...
Fabric Negative-ion Concentration Tester
Fabric Negative-ion Concentration Tester Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Fabric Negative-ion Concentration Testers typically detect the amount of nega...
Oil Heated Electrical Breakdown Tester CE Certified
Oil Heated Electrical Breakdown Tester CE Certified Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com High temperature voltage breakdown tester (oil heating) is mainly suitable fo...
Automotive Solar Simulation Test Chamber
Automotive Solar Simulation Test Chamber Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications Full Vehicle Sunlight Simulation Test Chamber is designed to evaluate the agi...
All supplier products

Same products

HDPE High Speed Water Cooled Double Wall Corrugated Pipe Extrusion Line
HDPE High Speed Water Cooled Double Wall Corrugated Pipe Extrusion Line Seller: Shandong HUASU Plastic Technology Co.,Ltd. The molds adopt the double flow channel structure and nitriding polishing processed die head. Thi...
PanEVAP & MVR system
PanEVAP & MVR system Seller: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd A multiple-effect evaporator is a device that efficiently uses steam heat to evaporate water. Wat...
PanGAP wide gap welded plate heat exchanger
PanGAP wide gap welded plate heat exchanger Seller: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd PanGAP wide gap welded plate heat exchangerconsists of a welded plate pack with different channel...
PanBloc welded plate heat exchanger
PanBloc welded plate heat exchanger Seller: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd PanBloc welded plate heat exchangeris compact and efficient, although fully welded, is totally ac...
PanBox welded plate heat exchanger
PanBox welded plate heat exchanger Seller: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd PanBox welded plate heat exchangerconsists of a laser welded plate pack with optimized corrugated...