High-Precision Material Thermal Conductivity Tester

Get a quote:

Web: qinsun-lab.com

Email:serving@qinsun-lab。com

TheHigh-Precision Material Thermal Conductivity Tester is suitable for steady-state thermal performance evaluation of materials with low to medium thermal conductivity, including:

Thermal insulation materials

Plastics and polymer-based materials

Rubber and elastomer materials

Aerogel panels and advanced insulation boards

Vacuum glass and building energy-saving materials

Solid materials and powder materials (with appropriate sample configuration)

The instrument is widely used in universities, research institutes, quality inspection laboratories, and industrial material testing facilities for thermal conductivity and thermal resistance analysis.

Standards

The instrument is designed and operated in accordance with the following international and national standards:

GB/T 10295-2008

Thermal insulation — Determination of steady-state thermal resistance and related properties — Heat flow meter method

ASTM E1530

Standard Test Method for Evaluating the Resistance to Thermal Transmission of Materials by the Guarded Heat Flow Meter Technique

ASTM C518-04

Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus

Parameters

ItemSpecification
Thermal conductivity range (low range) 0.0001 – 1 W/m·K (resolution up to 0.1 mW/m·K)
Thermal conductivity range (extended) 0.001 – 300 W/m·K
Measurement accuracy ±1%
Sample size 50 × 50 to 300 × 300 mm
Maximum sample thickness ≤ 50 mm
Optional sample sizes 600 × 600 mm, 800 × 600 mm (customized)
Applicable sample form Solid materials, powder materials
Test duration 15 – 20 min
Hot plate temperature range Room temperature to 99.9 °C (standard)
Optional hot plate range Room temperature to 499.9 °C or higher (by agreement)
Hot plate control accuracy 0.1 °C
Cold plate temperature range 0 – 99.9 °C (standard); –10 – 99.9 °C optional
Cold plate temperature control Water-cooled, precision constant-temperature bath
Cold plate control accuracy 0.1 °C
Pressure range 0 – 1000 N
Pressure resolution 0.1 N
Thickness measurement range 0 – 50 mm
Thickness resolution 0.1 μm
Heat flow sensor Imported original heat flow meter
Test operation Fully automatic computer-controlled testing and data storage
Power supply AC 220 V / 50 Hz

Send product request

To: Standard Groups
Your E-mail:
Message text:


Send to other suppliers

Other supplier products

Sublimation Fastness Tester/Scorch Tester - Test Equipment
Sublimation Fastness Tester/Scorch Tester - Test Equipment Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com Color fastness tester for ironing sublimation - Testing instrument for ironing col...
Impact strength tester manufacturer
Impact strength tester manufacturer Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com Email: serving@qinsun-lab。com Main parameters: Impact speed:The impact speed of ...
NEXGEN Aviation Fuel Burner
NEXGEN Aviation Fuel Burner Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com The NexGen Aviation Fuel Burner is suitable for a variety of aerospace testing app...
Glove Thermal Insulation Tester BS 6526:2002
Glove Thermal Insulation Tester BS 6526:2002 Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com The Glove Thermal Insulation Tester is a precision instrument designed to evaluate...
Flooring Materials Abrasion Resistance Tester | ASTM ISO Testing Machine
Flooring Materials Abrasion Resistance Tester | ASTM ISO Testing Machine Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com The Flooring Materials Abrasion Resistance Tester is designed to evaluate the wear...
All supplier products

Same products

Stainless Steel Flux Cored Welding Wire E308T1-1 E308HT1-1 E308LT1-1 Gas Shielded FCAW Wire for 304 Stainless Steel Welding
Stainless Steel Flux Cored Welding Wire E308T1-1 E308HT1-1 E308LT1-1 Gas Shielded FCAW Wire for 304 Stainless Steel Welding Seller: 863048 Product Description stainless steel flux cored wire E308T1-1 E308HT1-1 E308LT1-1,FCAW stainless ...
E317LT1-1 Flux Cored Wire CO2 Stainless Steel 70% Flux Content 1.0/1.2/1.6mm Diameter OEM Customized 1200C Melting Point
E317LT1-1 Flux Cored Wire CO2 Stainless Steel 70% Flux Content 1.0/1.2/1.6mm Diameter OEM Customized 1200C Melting Point Seller: 863048 XUNZHUO STAINLESS STEEL CORED WELDING WIRE E317LT1-1 CLASSIFICATION: There are ones with diamet...
Mini Jewelry Laser Repair System – 60W to 400W Precision Welding
Mini Jewelry Laser Repair System – 60W to 400W Precision Welding Seller: Beijing JCZ Technology Co., Ltd The Mini Jewelry Laser Welding Machineis an advanced mini laser welding system engineered for pre...
Portable Backpack Laser Cleaning Machine – Lightweight, Efficient Rust & Paint Removal
Portable Backpack Laser Cleaning Machine – Lightweight, Efficient Rust & Paint Removal Seller: Beijing JCZ Technology Co., Ltd TheHCP-M SeriesBackpack Laser Cleaning Machinefeatures a compact pulsed fiber laser system, desig...
Suitcase Pulsed Laser Cleaning Machine | Ultra-Portable Handheld Fiber Laser Cleaner
Suitcase Pulsed Laser Cleaning Machine | Ultra-Portable Handheld Fiber Laser Cleaner Seller: Beijing JCZ Technology Co., Ltd The Suitcase Pulsed Laser Cleaning Machineis an ultra-portable, high-precision handheld fiber las...