Laboratory expansion tank pressure tester
Whats/App: +86 156 1874 6768
Web: standard-groups.com
The Expansion Tank Static Pressure Test Machine is a specialized system designed to evaluate the static pressure performance and leak resistance of automotive expansion tanks. You can adjust the static pressure from 0 up to a maximum of 5 bar, while controlling the flow rate of each sample from 0 to 8 liters per hour. The system includes indirect chamber heating for safety (Explosion Protection Level 1), automatic leak detection, and fail-safe shutdown of defective samples, providing a reliable and efficient solution for expansion tank testing.
Standards
The system supports compliance with major automotive engineering standards:
VW TL889 (4.1) – Volkswagen Group technical specification for interior and related component functional performance.
ESDG93-8A080-AA (3.6) – Ford engineering specification for component functionality and reliability.
GMW15310 (3.2.1.2) – General Motors global standard for material and component performance testing.
QV17004D (3.2.6) – BMW group specification for system component functionality and durability.
Parameters
| Parameter Category | Details |
|---|---|
| Test Bench Dimensions | 2200 × 2240 × 1550 mm (W × H × D) |
| Chamber Dimensions | 1000 × 800 × 1000 mm (W × H × D) |
| Rated Power | 9.5 kW |
| Test Medium | Glycol/Water |
| Pressure Range | 0 … 5 bar |
| Flow Rate per Sample | 0 … 8 l/h |
| Pressure Type | Static |
| Test Medium Temperature Range | 25 … +150°C |
| Environmental Temperature Range | 25 … +150°C |
| Test Channels | 6 |
Accessories
Indirectly heated test chamber
Flow control units for each sample
Leak detection sensors and safety interlocks
Liquid level monitoring and control system
Control unit with Windows/LabVIEW interface (optional for data logging)
Sample mounting brackets for expansion tanks
Test Procedures
Ensure the test area is clear and safe for operation.
Connect the system to the 9.5 kW power supply.
Fill the chamber and sample lines with glycol/water mixture.
Mount expansion tank samples in the test chamber.
Set the static pressure (0–5 bar) and flow rate (0–8 l/h) for each sample.
Activate the test system and indirect heating if required.
Monitor pressure, flow, and leak detection sensors throughout the test.
Automatically shut down any failed samples.
Record all test results for quality control or validation purposes.
After testing, safely drain the medium and allow the system to cool before removing samples.
Maintenance Information
Inspect sample mounting brackets, pressure sensors, and leak detection units before each test.
Verify flow control devices and chamber seals for proper operation.
Periodically calibrate pressure sensors and temperature controllers.
Clean the chamber and fluid circuits to prevent contamination.
Replace worn or defective components to maintain safe and accurate operation.
Send product request
Other supplier products
| Advanced Tribology Stick Slip Testing System for Automotive & Engineering Materials | Factory Direct China | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Features (1) High-precision measurement: combination of linear motor and for... | |
| Laboratory Haptic Skill Logging System for Touch Sensitivity Research | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards At present, there is no dedicated international standard specifica... | |
| Helmet fit height measurement system for EN 397 compliance certification | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Application Measure the wearing height of helmets to ensure the accuracy and... | |
| Intervertebral Fusion Cages Shear Fatigue Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com The Intervertebral Fusion Cages Shear Fatigue Tester is a specialized biomechanical testing... | |
| Schopper Abrasion Tester with ISO certification | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com The Schopper abrasion tester is a precision device specifically designed to e... |
Same products
| MMA-120 Handheld Arc Welder | Seller: 871183 | The MMA-120 Handheld Arc Welder from ChuangLi Electronic Technology Co., Ltd. is designed for con... | |
| SHX Series Circulating Fluidized Bed Steam Boiler | Seller: Hebei Genjux Boiler Co.,Ltd | Capacity: 10-35 t/hWorking pressure: 1.25-2.5 MPaOperating temperature: 194-400 ℃Applicable to bi... | |
| YQ(Y)W Series Oil/Gas Fired Vertical Thermal Oil Boiler | Seller: Hebei Genjux Boiler Co.,Ltd | Capacity: 7000-29200 KWOperating pressure: 0.8-1.0 MPaOperating temperature: 320℃Operating mode: ... | |
| DHL Series Coal-Fired Steam Boilers | Seller: Hebei Genjux Boiler Co.,Ltd | Capacity: 35-75 t/hOperating pressure: 1.25-5.4 MPaOperating temperature: 194-485℃Applicable to b... | |
| SZL Series Biomass Steam Boiler | Seller: Hebei Genjux Boiler Co.,Ltd | Capacity: 6-35 t/hWorking pressure: 1.0-2.5 MPaOperating temperature: 184-350 ℃Applicable fuel bi... |