Automatic Double Plate Thermal Conductivity Tester
Whats/App: +86 156 1874 6768
Web: standard-groups.com
Application
Building Engineering: Used to evaluate and optimize the thermal performance of building materials to improve the insulation and heat-resistant properties of buildings.
Industrial Engineering: Used to monitor and control the thermal conductivity performance of industrial equipment to improve production efficiency and reduce energy consumption.
Environmental Monitoring: Used to monitor and evaluate the environmental impact of building materials, such as thermal pollution and thermal environment.
Scientific Research: Used to research and develop new materials to improve their thermal conductivity and application value.
The design and operation procedures of these devices ensure the accuracy and reliability of measurements, providing important technical support for the fields of materials science and engineering.
Standards
GB/T 10294-2008:Determination of Steady State Thermal Resistance and Related Properties of Thermal Insulation Materials
GB/T 3399-1982:Test method for thermal conductivity of plastics - Heat - resistant plate method
GB/T 10801.1-2002:Thermal insulation polystyrene foam
GB/T 10801.2-2002:Extruded polystyrene foam
GB/T 3139-2005:Test method for thermal conductivity of fiber reinforced plastics
GB/T 17794-2008:Flexible foam rubber and plastic insulation products
ASTM C518:Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus
IS0 8301:Thermal Insulation — Determination of Steady-State Thermal Resistance and Related Properties — Heat Flow Meter Apparatus
DIN EN 12667:Thermal Performance of Building Materials and Products - Determination of Thermal Resistance by Means of Guarded Hot Plate and Heat Flow Meter Methods - Products of High and Medium Thermal Resistance
Technical Parameters
| Items | Parameters |
| Specimen standard size | 300mm × 300mm × H (5 ~ 40) mm |
| Specimen flatness | 0.1mm |
| Thermal conductivity measurement display range | (0.001 ~ 2.000) W / (m • K) |
| Thermal conductivity measurement accuracy | ± 3% |
| Thermal conductivity measurement Repeatability | ± 1% |
| Temperature resolution | 0.01 ℃ |
| Temperature control accuracy | 0.05 ℃ |
| Different types of thermal conductivity tester temperature measurement range | Model | Cold plate temperature control interface ℃ | Hot plate temperature control range ℃ |
| IMDRY3001-I | Room temperature - 95 ℃ | Room temperature - 100 ℃ | |
| IMDRY3001-Ⅱ | -℃ -5 ℃ - 95 ℃ | 15 ℃ - 95 ℃ | |
| IMDRY3001-Ⅲ | -10 ℃ - 95 ℃ | 10 ℃ - 95 ℃ | |
| IMDRY3001-IV | -15 ℃ - 95 ℃ | 5 ℃ - 95 ℃ | |
| IMDRY3001-V | -20 ° C - 95 ° C | 0 ° C - 95 ° C | |
| IMDRY3001-Ⅵ | -30 ℃ -95 ℃ | -10 ℃ -95 ℃ | |
| IMDRY3001-VII | -40 ℃- 95 ℃ | -20 ℃ - 95 ℃ | |
| Power supply | AC 220V ± 10%, 2.5KW | ||
| Specimen thickness | Standard 25mm, range (5 ~ 40) mm | ||
| Specimen thermal resistance requirements | the thermal resistance of the specimen should not be less than 0.1 (m2 • K) / W, and should meet the thickness of the standard thickness Requirements; if the lower limit of thermal resistance of the specimen is as low as 0.02 (m2 • K) / W, the accuracy does not necessarily meet the requirements. | ||
| Clamping force | No more than 2.5kPa | ||
Test Procedures
First: Prepare the accessories and test samples;
Open the instrument's test chamber;
Place the sample inside the chamber;
Close and lock the test chamber lid;
Measure the sample thickness using a depth gauge;
Open the positioning rod on the side of the chamber and flip it over;
Release the positioning rod;
Place another sample inside this chamber (the instrument has two identical heating units);
Turn on the low-temperature bath and power switch;
Pour in a certain amount of water;
Turn on the instrument and access the LCD screen operating interface;
Set the hot plate temperature, sample thickness, preheating time, and test time, etc.;
Click "Start";
The system forms a thermal cycle, and the sample is tested;
When the set time is reached, the instrument automatically stops. Open the chamber and remove the sample;
The test is complete. Turn off the instrument;
Analyze and compare the test data to evaluate the material's thermal conductivity.
Send product request
Other supplier products
| Microbial Barrier Tester | Y/T 0471.5-2017 is a newly updated standard, which specifies the experimental method for evaluating the bacteria-inhibiting performance of the cont... | |
| Aerosol Foams Flammability Tester,Automatic Reaction Calorimeter | Product Introduction This product complies with "Recommendations on the Transport of Dangerous Goods - Manual of Tests and Criteria" 31.6 Flammabi... | |
| Coating thickness gauge/film thickness gauge | Standard Coating Thickness Gauge complies with international standards includingASTM B499,ASTM D1400,ISO 2178,ISO 2360, andGB/T 4956, ensuring rel... | |
| Intramedullary Nails/Bone Screw Static Torque Testing Machine | Standard YY/T 0591-2011: Chinese standard specifying torsion testing methods for intramedullary nails, including torque application, angular displ... | |
| Demesia Zigzag Tester | The Demesia Zigzag Tester is a professional device used to test the flexural resistance of materials such as rubber, leather, synthetic leather, an... |
Same products
| Tabletop Xenon Arc Weathering Tester (SunMaster) | Seller: Standard Groups | Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com The Water-Cooled Xenon Lamp Weat... | |
| Blow-By Test Rig | Seller: Standard Groups | Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com Test system for the characterisa... | |
| Air filter System(ISO 16890/EN 779) | Seller: Standard Groups | Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com Filter test system for general a... | |
| Oil Thread Leak Test System | Seller: Standard Groups | Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com Test System for oil thread leak ... | |
| Manual HEPA/ULPA Filter Scanning Test System | Seller: Standard Groups | Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com The Manual HEPA/ULPA Filter Scan... |