Film Shrinkage Testing Machine

Whats/App: +86 156 1874 6768

Web: standard-groups.com

Applications

The film heat shrinkage rate tester is mainly used to test the heat shrinkage performance and dimensional stability of various film materials, heat - shrinkable tubes, pharmaceutical PVC sheets, backplanes, etc. in liquid media at multiple temperatures. By precisely measuring the dimensional changes of the film before and after heating and calculating its heat shrinkage rate, the heat shrinkage performance of the material can be evaluated. This performance is directly related to the quality and reliability of products. In the packaging industry, such as in the fields of food, beverages, cosmetics, etc., film materials are widely used for product packaging. The quality of their heat shrinkage performance directly affects the packaging effect and product safety. Through the testing of the film heat shrinkage rate tester, problems that may occur during the heat shrinkage process of materials, such as uneven shrinkage and failure to meet the shrinkage rate standard, can be promptly identified and resolved, thus ensuring the quality of packaging materials.

Standards

ASTM D2732: Standard Test Method for Unrestrained Linear Thermal Shrinkage of Plastic Film and Sheeting

ISO 14616:1997: Plastics — Heat shrinkable films of polyethylene, ethylene copolymers and their mixtures — Determination of shrinkage stress and contraction stress

DIN 53369: Testing of plastic films; determination of the shrinking stress

GB/T 13519-2016:Polyethylene heat-shrinkable film for packaging applications

Technical Parameters

Items Specifications
Specimen Size ≤140 mm x 140 mm
Temperature Range Room temperature ~ 200°C
Accuracy ±0.2°C
Power Supply AC 100-240V 50/60Hz
(can be changed to local requirement)
Instrument Dimension 440 mm (W) x 370 mm (D) x 310 mm (H)
Net Weight 24 kg

Accessoriess

Standard Configurations: Instrument, Micro Printer, 1 Set of Clamp Wire Meshes

Optional Parts: Clamp Wire Mesh and Clamp Wire Mesh Support

Test Procedures

1. Equipment Preparation

Check that the liquid heating medium (e.g., silicone oil) is sufficient. Connect the power supply, turn on the instrument, preheat, and calibrate the temperature control system to ensure the temperature stabilizes within the required test range.

2. Sample Preparation

Cut film samples (e.g., 100x100mm) according to standards such as ASTM D2732. Measure and record the initial length and width dimensions of the sample using calipers.

3. Parameter Settings

Select the compliant standard through the instrument interface and set the test temperature (multiple temperatures are available), holding time, and other test conditions.

4. Test Start

Place the sample flat in the liquid heating medium without constraint, start the test program, and maintain the set temperature and duration to complete the heat shrinkage process.


Send product request

To: Standard International Group (HK) Limited
Your E-mail:
Message text:


Send to other suppliers

Other supplier products

Automatic Reaction Calorimeter
Automatic Reaction Calorimeter Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards GB 51283 GB/T 22232 GB/T 17802 SN/T 3078.1 Product Features 1. It offers th...
 Tracking indices of solid insulating materials Test Machine ,IEC60112
Tracking indices of solid insulating materials Test Machine ,IEC60112 Whats/App: +86 156 1874 6768 Web: standard-groups.com Introduction This tester is in accordance with IEC60112 standard . It is suitable for li...
Solar Simulation Chamber
Solar Simulation Chamber Whats/App: +86 156 1874 6768 Web: standard-groups.com Features and Benefits 1.Full-spectrum precise reproduction a 4500 Wwater-cooledxenon arc ...
Composite Material Dynamic Mechanical Torsional Braid Tester ISO 6721
Composite Material Dynamic Mechanical Torsional Braid Tester ISO 6721 Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards (1) HST-BW-500 — Torsional Braid Analysis Method (2) SN/T 3...
Cleveland Open Cup Flash Point Tester for Oil Quality Control ASTM Standard
Cleveland Open Cup Flash Point Tester for Oil Quality Control ASTM Standard Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards (1)ASTM D92:Standard Test Method for Flash and Fire Points by Clev...
All supplier products

Same products

HDPE High Speed Water Cooled Double Wall Corrugated Pipe Extrusion Line
HDPE High Speed Water Cooled Double Wall Corrugated Pipe Extrusion Line Seller: Shandong HUASU Plastic Technology Co.,Ltd. The molds adopt the double flow channel structure and nitriding polishing processed die head. Thi...
PanEVAP & MVR system
PanEVAP & MVR system Seller: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd A multiple-effect evaporator is a device that efficiently uses steam heat to evaporate water. Wat...
PanGAP wide gap welded plate heat exchanger
PanGAP wide gap welded plate heat exchanger Seller: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd PanGAP wide gap welded plate heat exchangerconsists of a welded plate pack with different channel...
PanBloc welded plate heat exchanger
PanBloc welded plate heat exchanger Seller: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd PanBloc welded plate heat exchangeris compact and efficient, although fully welded, is totally ac...
PanBox welded plate heat exchanger
PanBox welded plate heat exchanger Seller: Yangzhou Panstar Heat Exchanger Equipment Co., Ltd PanBox welded plate heat exchangerconsists of a laser welded plate pack with optimized corrugated...