Applications
The catheter residual vacuum tester is mainly used to determine the physical properties of residual vacuum and leakage in suction catheters for the respiratory tract and other similar medical devices. It is one of the important means to evaluate the performance of medical devices such as suction catheters for the respiratory tract, ensuring the safety and effectiveness of these devices during use. By testing the residual vacuum of catheters, the effectiveness of the vacuum control device at the machine end in releasing vacuum can be verified, thus ensuring that respiratory catheters can meet specific performance requirements during use. In addition, this tester can also be used for detecting vacuum leakage in catheter systems of medical devices such as hemodialysis machines, intravenous infusion devices, and ventilators, to promptly identify and resolve leakage issues and avoid medical accidents caused by leakage.
Standards
YY/T 0339 - 2019: Suction Catheters for the Respiratory Tract
Technical Parameters
| Parameter | Specification |
|---|---|
| Measurement Range (Flowmeter) | Usually can measure 30L/min or more |
| Accuracy (Flowmeter) | ±5% or higher |
| Airflow Resistance at a Specific Flow Rate (e.g., 30L/min) | Should be less than 0.1kPa |
Accessoriess
Main unit
Miniature printer
Touchscreen LCD display
Vacuum pump
Test Procedures
Open-system catheter: Open the catheter vacuum control device to the release position, turn on the vacuum pump, and adjust the flow rate to the specified value (e.g., 30 L/min).
Closed-system catheter: Remove the pressure gauge, turn on the vacuum control device and vacuum pump, adjust the flow rate to the specified value, then switch the vacuum control device to the closed position, and reattach the pressure gauge. Read and record the residual vacuum value measured on the pressure gauge, which is usually expressed in kPa. For respiratory tract suction catheters, the residual vacuum should not exceed the specified value (e.g., 0.33 kPa or 3.4 cmH₂O).
Send product request
Other supplier products
| ASTM needle flame tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Application The needle flame tester is widely used in various fields, including but not li... | |
| Aviation Fuel Safety Testing Burner | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The NexGen Burner supports compliance with multiple international aviation and s... | |
| Real-time gas monitoring system for battery thermal runaway testing | Whats/App: +86 156 1874 6768 Web: standard-groups.com Application Battery Research and Development Provides controlled thermal runaway testing ... | |
| Smoke Density Chamber, ISO 5659,Smoke density testing equipment | Whats/App: +86 156 1874 6768 Web: standard-groups.com Introduction The main principle is to measure smoke density in a particular space, cable o... | |
| Robot-based Filter Scanning Equipment factory | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com The Robot HEPA/ULPA Filter Scanning Detection System is designed to evaluate ... |