Dry Microbial Penetration Resistance Tester

Whats/App: +86 156 1874 6768

Web: standard-groups.com

The Dry Microbial Penetration Resistance Tester assesses material resistance to dry bacteria-carrying particles (like human dandruff-sized). It tests protective gear (surgical gowns, etc.) per ISO 22612. part of EN 13795 and EN 14126 test suites. Compliance with EN 13795 aligns with EU Medical Device Directive 93/42/EEC, crucial for CE marking in Europe.

Application

Dry microbial penetration resistance performance tester is professionaly used to determine the bacterial penetration resistance performance of materials to dry particulates in the size range of human body dandruff.Whenn testing, the samples were fixed on a container respectively.In these containers, five containers containing subtilisin talc, one container added with Not stained talcum powder was used as a control.A Petri dish was inserted at the bottom of each container at a distance from the bottom of the timer.

The equipment supporting the container is oscillated by a Gas ball oscillator, and all the talc penetrating the sample Falled on the culture dish , cultured without the culture vessel.The test results were evaluated by counting the growing colonies.

Standards:

ISO 22612:Clothing for protection against infectious agents - Test method for resistance to dry microbial penetration

YY / T 0506.5-2009:Surgical drapes, gowns and clean air suits for patients, clinical staff and equipment - Part 5: Test method for resistance to dry microbial penetration

Features

Reliable design, stable test;

Front switch glass doors, easy to observe the operation of the experimental staff;

Removable bracket, height adjustable bracket;

Support, mobile dual casters;

Negative pressure experimental system, with the fan exhaust system and the introduction of high efficiency filter to ensure the safety of operators;

Embedded high - speed industrial microcomputer control;

Dedicated operating software, with software parameters calibration, fault detection automatically

Test principle

When testing, the samples were seperately fixed on a container.In these containers, five containers carrying the bacillus subtilis and 1 container carrying uncontaminated talc powder used as control.Insert 1 petri dish at the bottom of each container and beneathe the bottom of the specimen.

The supporting vessel's equipment is oscillated by a gas ball type oscillator, and all of the talcum powder passing through the sample falls onto the petri dish. Remove the petri dish for culture. The experiment results were evaluated by counting the colonies.

Main parameters

Parameter NameParameter Value
Vibration form pneumatic ball vibrator
Vibration frequency 20800 times/min
Vibration force 650N
Worktable size 40cm × 40cm × 10mm
Workbench media marble plate
Experimental container stainless steel test container
Work stations 6
Cabinet negative pressure range -50 Pa ~ -200 Pa
High efficiency filter filtration efficiency better than 99.99%
Negative pressure cabinet ventilation flow ≥ 5m³/min
Data storage capacity 100.000 group
Working voltage 220V 50HZ

Send product request

To: Standard International Group (HK) Limited
Your E-mail:
Message text:


Send to other suppliers

Other supplier products

Mattress Fatigue Tester
Mattress Fatigue Tester Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com The Mattress Rollator is a laboratory durability testing system designed to e...
GAS Combustion Rate Tester,ISO817,Testing Machine
GAS Combustion Rate Tester,ISO817,Testing Machine Whats/App: +86 156 1874 6768 Web: standard-groups.com Introduction The combustible gas combustion rate tester is developed in accordance with th...
abrasion tester for perforated leather materials
abrasion tester for perforated leather materials Whats/App: +86 156 1874 6768 Web: standard-groups.com Application This single-station tester performs abrasion (fiber fluff) tests in compliance...
Single Burning Item,test apparatus, BS EN 13823
Single Burning Item,test apparatus, BS EN 13823 Whats/App: +86 156 1874 6768 Web: standard-groups.com Introduction Single burning instrument (SBI) was measured supplies (excluding floorings) p...
Airflow conditioning environmental chamber for product reliability testing
Airflow conditioning environmental chamber for product reliability testing Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com The Airflow Conditioning Environmental Chamber is an advanced high-end experi...
All supplier products

Same products

MMA-120 Handheld Arc Welder
MMA-120 Handheld Arc Welder Seller: 871183 The MMA-120 Handheld Arc Welder from ChuangLi Electronic Technology Co., Ltd. is designed for con...
SHX Series Circulating Fluidized Bed Steam Boiler
SHX Series Circulating Fluidized Bed Steam Boiler Seller: Hebei Genjux Boiler Co.,Ltd Capacity: 10-35 t/hWorking pressure: 1.25-2.5 MPaOperating temperature: 194-400 ℃Applicable to bi...
YQ(Y)W Series Oil/Gas Fired Vertical Thermal Oil Boiler
YQ(Y)W Series Oil/Gas Fired Vertical Thermal Oil Boiler Seller: Hebei Genjux Boiler Co.,Ltd Capacity: 7000-29200 KWOperating pressure: 0.8-1.0 MPaOperating temperature: 320℃Operating mode: ...
DHL Series Coal-Fired Steam Boilers
DHL Series Coal-Fired Steam Boilers Seller: Hebei Genjux Boiler Co.,Ltd Capacity: 35-75 t/hOperating pressure: 1.25-5.4 MPaOperating temperature: 194-485℃Applicable to b...
SZL Series Biomass Steam Boiler
SZL Series Biomass Steam Boiler Seller: Hebei Genjux Boiler Co.,Ltd Capacity: 6-35 t/hWorking pressure: 1.0-2.5 MPaOperating temperature: 184-350 ℃Applicable fuel bi...