Photovoltaic environmental acid mist chamber ASTM B117 standard
Get a quote:
Whats/App: +86 156 1874 6768
Web: standard-groups.com
The Photovoltaic Acid Mist Test Chamber is a specialized environmental simulation system designed to replicate highly corrosive coastal and industrial atmospheres. By precisely controlling salt mist concentration, multi-gas concentrations, temperature, and humidity, this chamber accelerates the degradation process of photovoltaic materials. It allows you to evaluate the corrosion resistance and predict the operational lifespan of PV modules exposed to harsh, salt-laden, or chemically aggressive environments.
Applications
The Photovoltaic Acid Mist Test Chamber is a specialized device designed to simulate coastal environments with high salt fog concentrations, enabling the evaluation of photovoltaic modules' corrosion resistance. Its core function involves precisely controlling salt mist concentration, temperature, and humidity to accelerate material aging processes, thereby assessing product lifespan under harsh environmental conditions.
Standards
IEC 60068-2-42. IEC 60068-2-43. IEC 60068-2-60
GB/T 10125 Artificial Atmosphere Corrosion Tests - Salt Spray Test
ISO 9227 Corrosion Tests under Artificial Atmospheres - Salt Spray Test
ASTM B117 Laboratory Simulation of Salt Spray Environments (e.g., Marine or Humid Climates)
Features
1.Multi-Gas Synergy: Unlike standard salt spray boxes, this system allows you to introduce $H_2S$, $NO_2$, and $Cl_2$ simultaneously, providing a more realistic "industrial-marine" complex environment.
2.Large-Format Throughput: The internal architecture is optimized to hold six full-sized PV modules, ensuring your testing throughput meets industrial R&D demands.
3.High-Precision Flow Control: Equipped with advanced flowmeters (accuracy $<pm 1%$), giving you total confidence in the repeatability of gas concentration levels.
4.Corrosion-Resistant Build: The chamber interior is constructed from reinforced, high-temperature resistant plastics or specialized alloys to withstand acidic and saline exposure without self-corrosion.
5.Automated Cycle Management: You can program complex sequences of spraying, drying, and humidifying to simulate changing weather patterns over a single test period.
Parameters
| No. | Item | Specifications |
|---|---|---|
| 1 | Temperature Range | +10°C ~ +70°C |
| 2 | Humidity Range | 40% ~ 98% RH (adjustable) |
| 3 | Test Capacity | 6 pieces of 2m × 1.2m photovoltaic modules |
| 4 | Test Gases | Four gases: SiO₂ (Silicon Dioxide), H₂S (Hydrogen Sulfide), NO₂ (Nitrogen Dioxide), Cl₂ (Chlorine).Concentrations can be automatically adjusted according to standard requirements.Flow meter control accuracy: better than ±1% |
Accessories
1.Adjustable Sample Racks: Specialized holders designed to support heavy PV modules at the required angles.
2.Gas Concentration Monitoring System: Real-time sensors for toxic/corrosive gas levels.
3.Exhaust Gas Scrubber: An integrated neutralization unit to safely treat acid mists and gases before venting to the outside.
4.High-Precision Saltwater Reservoir: Includes automatic level monitoring and pre-heating capabilities.
5.Air Compressor Interface: High-stability pressure regulator for consistent mist atomization.
Send product request
Other supplier products
| ASTM D3574 compliant sponge compression hardness tester | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com This machine is used to measure the indentation hardness of porous elastic ma... | |
| Photovoltaic module damp heat test chamber | Whats/App: +86 156 1874 6768 Web: standard-groups.com The Photovoltaic Module Damp Heat Test Chamber is designed to simulate long-term tropical a... | |
| ASTM E84 Building Materials Surface Burning Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards This test apparatus conforms to the following international standards: ASTM E84... | |
| STD Battery short-circuit tester丨STD Battery short-circuit chamber | Whats/App: +86 156 1874 6768 Web: standard-groups.com Product Introduction Battery Short Circuit Tester is a device that can be applied to the e... | |
| high low temperature gravel impact tester for coatings | Whats/App: +86 156 1874 6768 Web: standard-groups.com Application This tester is widely applied in durability and damage resistance evaluation f... |
Same products
| MMA-120 Handheld Arc Welder | Seller: 871183 | The MMA-120 Handheld Arc Welder from ChuangLi Electronic Technology Co., Ltd. is designed for con... | |
| SHX Series Circulating Fluidized Bed Steam Boiler | Seller: Hebei Genjux Boiler Co.,Ltd | Capacity: 10-35 t/hWorking pressure: 1.25-2.5 MPaOperating temperature: 194-400 ℃Applicable to bi... | |
| YQ(Y)W Series Oil/Gas Fired Vertical Thermal Oil Boiler | Seller: Hebei Genjux Boiler Co.,Ltd | Capacity: 7000-29200 KWOperating pressure: 0.8-1.0 MPaOperating temperature: 320℃Operating mode: ... | |
| DHL Series Coal-Fired Steam Boilers | Seller: Hebei Genjux Boiler Co.,Ltd | Capacity: 35-75 t/hOperating pressure: 1.25-5.4 MPaOperating temperature: 194-485℃Applicable to b... | |
| SZL Series Biomass Steam Boiler | Seller: Hebei Genjux Boiler Co.,Ltd | Capacity: 6-35 t/hWorking pressure: 1.0-2.5 MPaOperating temperature: 184-350 ℃Applicable fuel bi... |