Garment Electromagnetic Radiation Shielding Performance Testing System
Getaquote:
Whats/App: +86 181 0160 0864
The Garment Electromagnetic Radiation Shielding Performance Testing System is a comprehensive testing solution designed to evaluate the shielding effectiveness of protective clothing against electromagnetic radiation. Using a microwave test manikin in a controlled semi-anechoic chamber, the system measures the attenuation of electromagnetic waves on the head, chest, and abdomen of a dressed manikin. By simulating real-life conditions, the system provides accurate, reproducible assessment of garments’ protective performance across different frequencies.
Application
The system is suitable for a wide range of applications:
Assessing electromagnetic shielding performance of protective clothing in research and development
Evaluating finished garments and critical raw materials for EMF protection
Supporting quality control in textile and wearable electronics industries
Verifying compliance of protective apparel used in industrial, medical, or military environments
Standards
The testing system supports compliance with the following standards:
GB 23463-2025 – Protective Clothing for Microwave Radiation
GB/T 33615-2017 – Methods for Testing Electromagnetic Shielding Performance of Garments
DIN 32780-100 – Protective Clothing, Part 100: Electromagnetic Field Protection in 80 MHz–1 GHz Range
IEC 61000-4-3 – Testing and Measurement Techniques for Radiated RF Electromagnetic Fields
ISO 105-X12 – Textiles: Color Fastness to Electromagnetic Effects (Reference for material durability)
Parameters
| Parameter | Specification |
|---|---|
| Test Object | Protective garments, including finished products and key raw materials |
| Test Environment | Semi-anechoic chamber with low electromagnetic interference |
| Frequency Range | 80 MHz – 1 GHz (standard) |
| Measurement Points | Head, chest, abdomen of manikin |
| Sensors | Embedded EMF receiving sensors in manikin |
| Radiation Source | Signal amplifier with directional transmitting antenna |
| Shielding Effectiveness Measurement | Vector Network Analyzer (VNA) |
| Environmental Conditions | Controlled temperature and humidity to minimize measurement variability |
| Data Output | Real-time attenuation curves and shielding performance reports |
| Power Supply | AC 220V, 50/60 Hz |
| Footprint | Chamber and system optimized for laboratory installation |
Features
Realistic simulation of human exposure using test manikin
Semi-anechoic chamber minimizes external electromagnetic interference
High-precision vector network analyzer measures shielding effectiveness accurately
Multi-point measurement captures shielding at head, chest, and abdomen
Supports evaluation of raw materials, components, and finished garments
Integrated software for data acquisition, analysis, and automatic report generation
Capable of long-term performance evaluation including wash and abrasion tests
Accessories
Semi-anechoic chamber / electromagnetic shielded room
Microwave test manikin with embedded sensors
Vector Network Analyzer (VNA)
Signal amplifier with directional transmitting antenna
Environmental control sensors for temperature and humidity
Data acquisition and analysis software
Support fixtures for garment placement
Test Procedures
Sample Preparation
Include finished garments and critical raw materials to evaluate both overall and component-level shielding.
Ensure garments are properly mounted on the manikin with sensors correctly positioned.
Environmental Control
Conduct testing in a low-noise, semi-anechoic chamber to minimize external electromagnetic interference.
Measurement
Activate the electromagnetic radiation source and record real-time attenuation at head, chest, and abdomen using the manikin sensors.
Use the Vector Network Analyzer to measure shielding effectiveness across the target frequency range.
Durability Assessment
Optionally perform wash, friction, and other stress tests on the garment before re-evaluating shielding performance.
Data Recording
Analyze and record results with integrated software, generating performance curves and standardized reports.
Maintenance Information
Regularly inspect and calibrate the vector network analyzer and sensors to ensure accuracy
Maintain semi-anechoic chamber cleanliness and check shielding integrity periodically
Verify signal amplifier and antenna operation before each test
Ensure environmental sensors are functional and provide accurate temperature and humidity readings
Store manikin and sensitive components properly when not in use to prevent mechanical or electrical damage
Send product request
Other supplier products
| Circular Locus Pilling Tester | Getaquote: Whats/App: +86 181 0160 0864 The G235P Circular Locus Pilling Tester is used to evaluate the pilling and fuzzing behavior of fabrics, ... | |
| Automated Filter Element Test System | Get a quote: Whats/App: +86 181 0160 0864 Web: gellowen.co.uk Test System for production control of filter elements (e.g. exhaust filter, HEPA f... | |
| Color fastness tester for ironing sublimation | Getaquote: Whats/App: +86 181 0160 0864 G247B Color fastness tester for ironing sublimation, It is used for the performance test of color fastnes... | |
| Drawer slide durability testing machine | Get a quote: Whats/App: +86 181 0160 0864 Web: gellowen.co.uk The Drawer Slide Durability Testing Machine is designed to evaluate the mechanical... | |
| Thermal - Cold Cycle Testing Machine | Get a quote: Whats/App: +86 181 0160 0864 Web: gellowen.co.uk The Thermal-Cold Cycle Testing Machine is a professional equipment used for high a... |
Same products
| MMA-120 Handheld Arc Welder | Seller: 871183 | The MMA-120 Handheld Arc Welder from ChuangLi Electronic Technology Co., Ltd. is designed for con... | |
| SHX Series Circulating Fluidized Bed Steam Boiler | Seller: Hebei Genjux Boiler Co.,Ltd | Capacity: 10-35 t/hWorking pressure: 1.25-2.5 MPaOperating temperature: 194-400 ℃Applicable to bi... | |
| YQ(Y)W Series Oil/Gas Fired Vertical Thermal Oil Boiler | Seller: Hebei Genjux Boiler Co.,Ltd | Capacity: 7000-29200 KWOperating pressure: 0.8-1.0 MPaOperating temperature: 320℃Operating mode: ... | |
| DHL Series Coal-Fired Steam Boilers | Seller: Hebei Genjux Boiler Co.,Ltd | Capacity: 35-75 t/hOperating pressure: 1.25-5.4 MPaOperating temperature: 194-485℃Applicable to b... | |
| SZL Series Biomass Steam Boiler | Seller: Hebei Genjux Boiler Co.,Ltd | Capacity: 6-35 t/hWorking pressure: 1.0-2.5 MPaOperating temperature: 184-350 ℃Applicable fuel bi... |