Filter Media Filtration Performance Test Bench

Get a quote:

Whats/App: +86 156 1874 6768

Web: standard-groups.com

The Filter Media Filtration Performance Test Bench G508 is designed to evaluate the filtration performance and durability of filter media and filter bags used in baghouse dust collectors under simulated real operating conditions.Using a horizontal airflow duct structure without vertical piping, you can reproduce realistic dust loading, cleaning, and aging processes. The system allows filter media to be tested under a stable dust cake condition, providing reliable data on pressure drop behavior, filtration efficiency, residual resistance, and dust penetration during continuous loading and pulse-cleaning cycles.

Standards

The G508 test bench supports parameterized test conditions in accordance with the following standards:

(1) GB/T 6719 — Technical requirements for baghouse dust collectors

(2) ISO 11057 — Air quality; test methods for filtration performance of cleanable filter media

(3) ASTM D6830 — Test method for pressure drop and filtration performance of cleanable filter media

(4) VDI/DIN 3926 — Evaluation methods for cleanable filter media

(5) JIS Z 8909-1 — Test method for filter media for dust collection, Part 1

Parameters

Duct and System Structure (Horizontal Duct)

ItemTechnical Parameter
Duct configuration Horizontal airflow duct
Dirty air duct cross-section Rectangular, 110 mm × 290 mm
Clean air flow range 0–10 m³/h
Overall system dimensions Approx. 2300 mm × 1000 mm × 3500 mm
System weight Approx. 350 kg
Power supply AC 220 V, 50/60 Hz, 15 A

Sensors and Measurement System

ItemTechnical Parameter
Temperature range 0–100 °C
Temperature accuracy ±0.2 °C
Pressure range 0–1200 mbar
Pressure accuracy ±0.3 %
Differential pressure range 0–2500 Pa
Differential pressure accuracy ±0.1 %
Airflow measurement range 0–12 m³/h
Flow accuracy ±1 %

Dust Generation and Concentration Control

ItemTechnical Parameter
Dust feed rate 42–430 g/h
Dust concentration range 0.8–100 g/m³
Concentration control accuracy ≤ ±5 %
Dust hopper volume 5.5 L
Test dust types Standard dust, SAE dust, Fine A2. Pural SB

Particle Size and Filtration Efficiency Analysis

ItemTechnical Parameter
Particle size range 0.2–40 μm
Particle concentration range 1–4.000.000 /L
Measurable indices PM10 / PM2.5 / PM1
Measurement principle 90° light scattering with filter sampling
Analysis functions Fractional efficiency and counting efficiency

Features

(1) Horizontal airflow structure without vertical ducting, providing stable flow distribution for flat filter media testing

(2) High-repeatability dust loading system suitable for long-term aging and cleaning cycle tests

(3) Simultaneous online monitoring of pressure drop, filtration efficiency, particle size distribution, and dust penetration

(4) Flexible test configuration to meet multiple international standard requirements

(5) Automated data acquisition with curve display and Excel data export for further analysis


Send product request

To: Standard International Group (HK) Limited
Your E-mail:
Message text:


Send to other suppliers

Other supplier products

Squirrel Cage Method Smoke Toxicity Chamber Factory Direct
Squirrel Cage Method Smoke Toxicity Chamber Factory Direct Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com E-mail:info@standard-groups。com Parameters ItemSpecification Qua...
Suitcases Vibration Impact Tester
Suitcases Vibration Impact Tester Whats/App: +86 156 1874 6768 Web: standard-groups.com This machine is used to test the shock resistance of various luggage handles, car stitches ...
Film Heat Shrinkage Tester
Film Heat Shrinkage Tester Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications The film heat shrinkage rate tester is mainly used to test the heat shrinkage...
Industrial Linear Reciprocating Friction and Wear Tester
Industrial Linear Reciprocating Friction and Wear Tester Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards GB/T 3960-2016 Plastics – Determination of Sliding Wear Properties GB/T 1...
Ergonomics and Human Thermal Response Measurement
Ergonomics and Human Thermal Response Measurement Whats/App: +86 156 1874 6768 Web: standard-groups.com Application The Porton-man Thermal Manikin is suitable for a wide range of applications, i...
All supplier products

Same products

China factory electrode TGYS125 for power station Selection of advanced
China factory electrode TGYS125 for power station Selection of advanced Seller: DONGFANG YOYIK (DEYANG) ENGNIEERING CO; LTD "China factory electrode TGYS125 for power station Selection of advanced technology, absolutely f...
Laser Chuck
Laser Chuck Seller: Drake precision technology (changzhou) Co.,Ltd. Laser Chuck Introduce foreign advanced technology and management concept, High precision pro...
Power Pallet Jack For Sale
Power Pallet Jack For Sale Seller: Jinan Hulk Machinery Co., Ltd Power Pallet Jack For Sale Electric Pallet Truck For Sale As a supplier of power pallet jac...
Multi Directional Forklift For Sale
Multi Directional Forklift For Sale Seller: Jinan Hulk Machinery Co., Ltd Multi Directional Forklift For Sale Multi Directional Forklift For Sale As a supplier of mu...
Narrow Aisle Forklift For Sale
Narrow Aisle Forklift For Sale Seller: Jinan Hulk Machinery Co., Ltd Narrow Aisle Forklift For Sale Narrow Aisle Forklift For Sale As a supplier of , we provide...