Automated filter integrity test system manufacturer
Get a quote:
Whats/App: +86 156 1874 6768
Web: standard-groups.com
Applications
production control of integral separation efficiency of exhaust particle filters (GPF, DPF)
quality control of HEPA filters or filter cartridges of e.g. industrial vacuum systems
research and development on any small air filter elements
Standards
This system meets the requirements of:
(1) GB/T 14295-2019 – Air filters.
(2) GB/T 13554-2020 – High-efficiency air filters.
(3) GB/T 6165-2021 – HEPA filter performance testing: efficiency and resistance.
(4) ISO 29463-4 – High-efficiency air filter performance.
(5) ISO 16890 – Air filter performance standard.
(6) EN 1822 – HEPA and ULPA filter performance testing.
(7) ISO 5011 – Engine air intake filter testing.
Technical data
| Parameter | Unit | Value |
|---|---|---|
| Test flow rate | m³/h | 40 … 440 (up to 1200 optional) |
| Measuring range, particle size (OPC) | µm | 0.1 … 1.0 |
| Measuring range, particle size (CPC) | µm | 0.001 … 1.0 |
| Test cycle duration | s | approx. 30 |
| Test aerosol | – | Customer-specific (e.g., DEHS or others) |
| Dimensions of test specimen | – | Diameter ≤ 300 mm; Length ≤ 850 mm |
| Compressed air supply | bar | 4.0 … 6.0 |
| Power supply | – | 3 × 400 VAC, hard-wired; rated current 30 A; pre-fuse 32 A |
| Inner diameter of duct | mm | 150 |
| Aerosol-analytical instruments | – | Customer-specific (e.g., OPC, CPC, etc.) |
| Integrated sensors | – | Temperature, relative humidity, air pressure |
| Dimensions (W × H × D) | mm | 2800 × 2100 × 1200 |
| Weight | kg | approx. 800 |
Features
24/7 Operation: Automated safety features for continuous production.
Short Test Cycle: Complete aerosol supply, analysis, and sample removal within ~30 seconds.
Flexible Quality Standards: Adjustable separation efficiency and pressure drop thresholds.
Minimal Sample Load: Reduces stress on test samples, extending product life.
High Automation and Efficiency: Minimizes operator intervention, improves throughput.
Full Traceability: Barcode/QR code integration ensures complete production tracking.
Principle
A defined volumetric flow rate is sucked by a controlled blower from the environment through a HEPA inlet filter, the test duct and a safety filter. The test duct is composed of three functional sections, i.e., sections for i) the generation and characterisation of the test aerosol (upstream aerosol), ii) the incorporation of the test specimen (specimen adapter) and iii) the characterisation of the downstream aerosol.
Benefits
test system designed for 24/7 operation with automated safety functions
short test cycles (supply, analysis, removal) for separation efficiency and pressure drop
quality criteria for separation efficiency and pressure drop are freely configurable
minimal loading of test specimen (higher lifetime of products)
Send product request
Other supplier products
| Aerosol Sensor Test System,Aerosol and Dust Monitors Test System | Whats/App: +86 156 1874 6768 Web: standard-groups.com The Aerosol Sensor Test System is designed for development, testing, and calibration of act... | |
| Bus Seat Tester,Vehicle seat test equipment | Whats/App: +86 156 1874 6768 Web: standard-groups.com The Bus Seat Tester is designed to evaluate the durability, strength, and fatigue performan... | |
| Industrial Textile Strip Evenness Testing Machine ASTM International | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The Strip Evenness Tester aligns with common textile testing stand... | |
| Rapid screening Calorimeter | Whats/App: +86 156 1874 6768 Web: standard-groups.com Product Introduction: The rapid - screening calorimeter is a professional calorimetric ins... | |
| Surface performance testing machine | Whats/App: +86 156 1874 6768 Web: standard-groups.com Application Measurement of friction force and friction coefficient of metals, ceramics, po... |