Leakage Test System
Get a quote:
Whats/App: +86 181 0160 0864
Web: gellowen.co.uk
Test System for testing tightness and leackage for a high diversity of components and devices. With Leak Test Systems of series it is possible to test tightness against over and low-pressure of components of different dimensions and shapes. The leak rate is determined depending on pressure.
The test rig is working at test air temperatures from -40°C up to 120°C. A heat exchanger protects the measurement instrumentation against damages because of too low or high temperatures during low pressure operation. For external connection the test rig has a test air adapter, a pressure measurement port as well as a temperature sensor which have to be connected with the test sample. All connecting lines are 2 m long so that the sample can be in a climatic chamber during the test.
Applications
Tightness and leak testing of technical components and devices;
Sealing performance testing of automotive and engine system components;
Leakage detection of pipelines, valves, fittings, and pressure vessel assemblies;
Integrity verification of enclosure sealing for electronic, electrical, and electromechanical equipment;
Overpressure and vacuum testing of aerospace and rail transit components;
Sealing performance evaluation of medical devices and laboratory equipment;
Sealing tests under high- and low-temperature conditions in environmental test chambers;
Verification of sealing structure designs during new product development;
Sealing quality control in production lines and final inspection processes.
Standards
GB/T 4208 Degrees of Protection Provided by Enclosures (IP Code)
GB/T 10125 Corrosion Tests in Artificial Atmospheres – Salt Spray Tests
GB/T 15173 Sealing Test Methods for Electrical Equipment
GB/T 2423 (Series) Environmental Testing for Electric and Electronic Products
QC/T 413 Sealing Test Methods for Automotive Parts
JB/T 9092 Airtightness Test Methods for Industrial Products
ISO 20485 Non-destructive Testing – Leak Testing – General Methods
ASTM E283 Standard Test Method for Determining Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors Under Specified Pressure Differences Across the Specimen
Technical data
| Parameter | Unit | Value |
|---|---|---|
| Test flow rate | L/min | 0.005 … 300 (during operation) |
| Test pressure | kPa | – (0.1 … 90); + (0.1 … 500) |
| Operating medium (gas/air) | – | Dry, particle-free compressed air |
| Compressed air supply | bar | max. 8 (max. 600 L/min) |
| Power supply | – | 230 VAC |
| Environmental condition, temperature | °C | -40 … 120 |
| Power consumption | W | approx. 500 |
| System dimensions (W × H × D) | mm | 2000 × 1100 × 900 |
| Weight | kg | approx. 280 |
Send product request
Other supplier products
| Catheter Vacuum Leak Tester | Standards GB 15812.1 - 2005 Non - Vascular Intravascular Catheters - Part 1: General Performance Test Methods GB 8368 Disposable Infusion SetsYY ... | |
| Electric pencil hardness tester | Get a quote: Whats/App: +86 181 0160 0864 Web: gellowen.co.uk The Electric Pencil Hardness Tester is designed to determine the surface hardness ... | |
| Shoelace Abrasion Tester SATRA TM154 | Standards SATRA TM93、DIN-4843、QB/T2226、SATRA TM154 Principle Let shoelace cross the eyelet clamped on the fiber board, make the shoelace and eye... | |
| Infusion Set Positive Pressure Leakage Tester | Get a quote: Whats/App: +86 181 0160 0864 Web: gellowen.co.uk The Infusion Set Positive Pressure Leakage Tester is a dedicated testing instrumen... | |
| Anti-drill tester (Friction method) | Get a quote: Whats/App: +86 181 0160 0864 The Anti-Drill Tester (Friction Method) is designed to evaluate the drill and friction resistance of ma... |
Same products
| MMA-120 Handheld Arc Welder | Seller: 871183 | The MMA-120 Handheld Arc Welder from ChuangLi Electronic Technology Co., Ltd. is designed for con... | |
| SHX Series Circulating Fluidized Bed Steam Boiler | Seller: Hebei Genjux Boiler Co.,Ltd | Capacity: 10-35 t/hWorking pressure: 1.25-2.5 MPaOperating temperature: 194-400 ℃Applicable to bi... | |
| YQ(Y)W Series Oil/Gas Fired Vertical Thermal Oil Boiler | Seller: Hebei Genjux Boiler Co.,Ltd | Capacity: 7000-29200 KWOperating pressure: 0.8-1.0 MPaOperating temperature: 320℃Operating mode: ... | |
| DHL Series Coal-Fired Steam Boilers | Seller: Hebei Genjux Boiler Co.,Ltd | Capacity: 35-75 t/hOperating pressure: 1.25-5.4 MPaOperating temperature: 194-485℃Applicable to b... | |
| SZL Series Biomass Steam Boiler | Seller: Hebei Genjux Boiler Co.,Ltd | Capacity: 6-35 t/hWorking pressure: 1.0-2.5 MPaOperating temperature: 184-350 ℃Applicable fuel bi... |