Cabin Air Filter Test System(Particulate Filtration)
Get a quote:
Whats/App: +86 181 0160 0864
Web: gellowen.co.uk
Test system for testing particle separation of air filters for passenger compartments (DIN 71460-1, ISO/TS 11155-1). With the test system for cabin air filters acc. to DIN 71460-1 (particle filtration) all relevant filter performance parameters such as differential pressure drop, gravimetric or fractional filtration efficiency and dust holding capacity are determined.
The setup and configuration of the test system as well as the required test procedures are described in the standards DIN 71460-1 and ISO/TS 11155-1 for motor vehicle passenger compartment particle filtration.
Tests acc. to standards DIN 71460-2 and ISO 11155-2 can be carried out using PAF 112 test system for adsorptive cabin air filters.
For filter tests acc. to standards DIN 71460-1, ISO/TS 11155-1 and DIN 71460-2, ISO 11155-2 Topas has designed PAF 113 filter test system combining all features of test systems PAF 111 and PAF 112.
Applications
Differential pressure test
Analysis of fractional separation efficiencydust loading tests
Combined analyses according to DIN 71460-1 (ISO/TS 11155-1)
Customised tests
Standards
(1) GB/T 32085.1 — Automotive Air Conditioning Filters — Part 1: Dust Filtration Test
(2) ISO/TS 11155-1 — Road Vehicles — Cabin Air Filters — Part 1: Dust Filtration Test
(3) DIN 71460-1 — Road Vehicles — Passenger Compartment Air Filters — Part 1: Particulate Filter Test Methods
Features
Standard compliant testing of filter elements and filter mediamodular setup and instrumentation
Design on different flow rate and differential pressure ranges
High degree of automation
Traceable test documentation
Technical data
| Parameter | Unit | Value |
|---|---|---|
| Test flow rate | m³/h | 70 … 700 (higher flow rates on request) |
| Measuring range, differential pressure | Pa | 0 … 1000 |
| Compressed air supply (operating gas/air) | bar | 6 |
| Power supply | – | – |
| Test specimen dimensions | – | max. 300 × 600 mm |
| Aerosol generation technology | – | Dust disperser SAG 410/L, Atomizer ATM 220 |
| Aerosol conditioning technology | – | Electrical Aerosol Neutralizer EAN 581 |
| Aerosol measurement technology | – | Aerosol spectrometer |
| Sensors | – | Differential pressure, absolute pressure, temperature, relative humidity |
| System dimensions (W × H × D) | mm | 4600 × 3400 × 1200 |
Send product request
Other supplier products
| Industrial Dry Cleaning Machine | Getaquote: Whats/App: +86 181 0160 0864 The MST Medical Compression Stocking Tester is a professional instrument designed to evaluate the compres... | |
| Minimum Ignition Temperature (MIT) – Dust Cloud Tester | Get a quote: Whats/App: +86 181 0160 0864 Web: gellowen.co.uk Dust Cloud Minimum Ignition Temperature Tester is mainly used to assess the explos... | |
| Geosynthetics Vertical Penetration Tester丨Geotextile Test Machine | Scope of application: Used to determine the vertical permeability of geotextile and its related products under constant water head method. The wat... | |
| Kernel Test Instrument | Get a quote: Whats/App: +86 181 0160 0864 Web: gellowen.co.uk The Kernel Test Instrument (also known as the Koenen Test Apparatus) is a speciali... | |
| Qinsun UV-master | In response to the climate resistance testing requirements for outdoor textiles, this equipment can simulate outdoor climate conditions and accel... |
Same products
| MMA-120 Handheld Arc Welder | Seller: 871183 | The MMA-120 Handheld Arc Welder from ChuangLi Electronic Technology Co., Ltd. is designed for con... | |
| SHX Series Circulating Fluidized Bed Steam Boiler | Seller: Hebei Genjux Boiler Co.,Ltd | Capacity: 10-35 t/hWorking pressure: 1.25-2.5 MPaOperating temperature: 194-400 ℃Applicable to bi... | |
| YQ(Y)W Series Oil/Gas Fired Vertical Thermal Oil Boiler | Seller: Hebei Genjux Boiler Co.,Ltd | Capacity: 7000-29200 KWOperating pressure: 0.8-1.0 MPaOperating temperature: 320℃Operating mode: ... | |
| DHL Series Coal-Fired Steam Boilers | Seller: Hebei Genjux Boiler Co.,Ltd | Capacity: 35-75 t/hOperating pressure: 1.25-5.4 MPaOperating temperature: 194-485℃Applicable to b... | |
| SZL Series Biomass Steam Boiler | Seller: Hebei Genjux Boiler Co.,Ltd | Capacity: 6-35 t/hWorking pressure: 1.0-2.5 MPaOperating temperature: 184-350 ℃Applicable fuel bi... |