Micro Rapid Closed Cup Flash Point Tester | Pensky Martens ASTM D93
Get a quote:
Whats/App: +86 156 1874 6768
Web: standard-groups.com
Standards
(1)SN/T 3077.1-2012: Chemicals—Determination of flash point—Part 1: Closed-cup equilibrium method
(2)SN/T 3077.2-2012: Chemicals—Determination of flash point—Part 2: Closed-cup rapid equilibrium method
(3)SH/T 0768-2005: Determination of total contaminants in middle distillate fuel oils—High-temperature filtration method
(4)DL/T 1354-2014: Preparation method of working standard oil for analysis of dissolved gas components in transformer oil
(5)ASTM D93: Pensker-Martins closed-cup flash point determination
(6)ASTM D6450: Small closed-cup flash point determination method
(7)ASTM D3828: Small closed-cup device method for determining the flash point of liquids
(8)ASTM D7094: Improved continuous closed-cup flash point determination method
(9)ASTM D7236: Improved Abel closed-cup flash point determination method
(10)ASTM D56: Tiger closed-cup flash point determination method
(11)ISO 2719: Petroleum products—Determination of flash point—Pensker- Martins Closed Cup Method
(12)ISO 13736: Petroleum Products - Determination of Flash Point - Abel Closed Cup Method
(13)ISO 1516: Petroleum Products - Determination of Flash Point - Tiger Closed Cup Method
(14)ISO 1523: Petroleum Products - Determination of Flash Point - Small Closed Cup Method
(15)IP 34: Determination of Flash Point - Abel Closed Cup Tester Method
(16)IP 304: Determination of Flash Point - Small Closed Cup Method
(17)IP 170: Determination of Flash Point - Pensker-Martins Closed Cup Tester Method
(18)DIN EN 22719: Petroleum Products - Determination of Flash Point - Pensker-Martins Closed Cup Method
(19)JIS K2265: Petroleum Products - Determination of Flash Point
(20)NF M 07-019: Petroleum Products - Determination of Flash Point - Pensker-Martins Closed Cup Method
Features
(1)It adopts the advanced continuous closed - cup flash - point test method, which is more accurate and efficient.
(2)It requires a small sample amount, resulting in low test costs and minimal pollution.
(3)With continuous closed - cup operation, there is no open flame, ensuring high safety.
(4) It has a built - in refrigeration module, offering a wide flash - point test range and a fast cooling rate.
(5)Standard test methods are preset and can be associated with other closed - cup methods.
(6)It features fully automated detection and automatically corrects the flash - point based on atmospheric pressure.
(7) It displays temperature and pressure curves in real - time, making the test process more intuitive.
(8)The test results include a temperature - pressure rise curve, providing more information about flash combustion.
(9) Key components are from well - known international brands, ensuring long - term stable operation.
(10) It supports user - level management, enabling the management and control of accounts at different levels.
(11)The USB interface is plug - and - play. An optional thermal printer is available for convenient data management.
(12)It is equipped with a 7 - inch color touch screen that supports Chinese input, making the operation intuitive and simple.
Technical Parameters
|
Operating Environment |
(5~40)℃, <85%RH |
|
Temperature Range |
(0~260)℃ |
|
Rising Rate |
(-30~260)℃ (with low-temperature module) |
|
Temperature Detection Accuracy |
(0~420)℃ (with high-temperature module) |
|
Pressure Detection Range |
(-30~420)℃ (with low-temperature and high-temperature modules) |
|
Sample Volume |
(2.5±0.3)℃/min, (5.5±0.5)℃/min, |
|
Ignition Method |
(0.5~12)℃/min Customized |
|
Stirring Speed |
±0.1℃ |
|
Storage Space |
(0~200)kPa |
|
Interface |
1mL or 2mL |
|
Power |
High-pressure electronic ignition |
|
Power |
(50~300)rpm software can be set |
|
Dimensions |
5000 test results |
|
Weight |
RS232*1. RJ45*1. USB*2 |
Accessoriess
(1) Binsky-Martin Closed Cup Kit (includes a dedicated cup body and sealing cap, suitable for closed cup testing requirements)
(2)Micro-sample pipette (matches the instrument's micro-sample volume injection requirements)
(3)Spare ignition needle/igniter assembly (a spare part to ensure stable ignition function)
(4) Sealing ring for closed cup (a consumable sealing component for closed cup testing)
(5)Spare temperature sensor probe (a core spare part for temperature detection)
(6)Standard flash point sample for calibration (a known flash point standard oil compatible with ASTM D93. used for instrument calibration)
(7)Dedicated cleaning tools (such as brushes and wiping cloths, for cleaning and maintenance of components such as the cup body)
Send product request
Other supplier products
| Automated white light interferometry system | Whats/App: +86 156 1874 6768 Web: standard-groups.com Application The White Light Interferometer is widely used for non-contact surface topograp... | |
| Luggage lifting and unloading testing machine | Whats/App: +86 156 1874 6768 Web: standard-groups.com The luggage simulation lifting and unloading tester is a measuring instrument for the life ... | |
| Flat-Panel Air-Cooled Xenon Lamp Weathering Test Chamber | Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications Flat-Panel Air-Cooled Xenon Lamp Weathering Test Chamber employs xenon arc la... | |
| ISO 13937-1 Fabric Tear Strength Tester for Textile Laboratories | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Wide test range The tester is equipped with multiple ranges and is used for ... | |
| Fabric Wrinkle Tester Manufacturer | Whats/App: +86 156 1874 6768 Web: standard-groups.com The Fabric Wrinkle Bending Tester is a specialized instrument used to assess the wrinkle re... |