Cleveland Open Cup Flash Point Tester for Oil Quality Control ASTM Standard
Get a quote:
Whats/App: +86 156 1874 6768
Web: standard-groups.com
Standards
(1)ASTM D92:Standard Test Method for Flash and Fire Points by Cleveland Open Cup
(2)IP 36. 403:Determination of Flash and Fire Points by Cleveland Open Cup Method (IP 36/403)
(3)ISO 2592:Determination of flash and fire points - Cleveland open cup method
(4)AFNOR T60-118:Petroleum products - Determination of flash and fire points - Cleveland open cup method (AFNOR T60-118)
(5)EN 22592:Petroleum products - Determination of flash and fire points - Cleveland open cup method (EN 22592)
(6)DIN 51376:Testing of mineral oils; determination of flash and fire point by Cleveland open cup
Features
Automates the testing process for both flash point and ignition point, reducing operator intervention and potential for error.
Provides highly repeatable and reproducible test results, crucial for reliable product characterization.
Designed to comply with the ISO 2592 standard (Cleveland Open Cup Method).
Features an intuitive 5.5-inch color touch screen and programmable logic controller (PLC) for easy operation and test management.
Simplifies data processing and result management, enhancing laboratory efficiency.
Offers a convenient and efficient alternative to traditional manual testing methods.
Equipped with safety features necessary for handling flammable petroleum products.
Product Features
Automatic Test Procedure: Conducts the heating, test flame application, flash detection, and ignition point determination automatically.
Programmable Logic Controller (PLC): Enables precise control over the test parameters and sequences.
Touch Screen Interface (5.5"): Provides a user-friendly interface for setting up tests, monitoring progress, and viewing results.
Data Processing and Management: Capable of processing test data and facilitating easy management of results.
Micro Printer: For direct printing of test results for record-keeping.
Integrated Heating System: Precisely controls the sample temperature rise rate.
Automatic Ignition System: Applies the test flame at specified intervals.
Flash/Ignition Detection System: Reliably detects the flash and sustained ignition.
Parameters
| Description | Details |
|---|---|
| Dimensions | 550(W) x 400(D) x 320(H)mm |
| Table size | 1000(W) x 600(D) x 800(H)mm (assuming the "1.000" is a typo and should be "1000") |
| Power supply | AC 220V 50/60Hz, 15A |
| Weight | 30kg |
| Instruction manual | Available |
| Exhaust | Minimum 50L/s |
| Tools | Propane gas, vacuum cleaner |
Accessoriess
(1)Thermal fuse
(2)Gas hose
(3)Heating plate
(4)AC power cord
(5)Instruction manuals, etc.
Send product request
Other supplier products
| Film Heat Shrinkage Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications The film heat shrinkage rate tester is mainly used to test the heat shrinkage... | |
| ISO 4892 Solar Light Aging Tester Xenon Arc Accelerated Aging Test Chamber | Whats/App: +86 156 1874 6768 Web: standard-groups.com HJ ISO 4892 Solar Light Aging Tester Xenon Arc Accelerated Aging Test Chamber Xenon Lamp We... | |
| Air permeability machine with ISO compliance | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com The Air Flow Resistance Tester is designed to quantitatively evaluate the air... | |
| Mattress Durability Fatigue Testing Machine | Whats/App: +86 156 1874 6768 Web: standard-groups.com The Mattress Durability Fatigue Testing Machine evaluates the fatigue resistance and surfac... | |
| Friction and wear testing machine | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards ASTM G99-04 ASTM G77-16 ISO 9352:1995 GB/T 12444-2006 GB/T 12607-2007 GB/T ... |