ISO 11431 Si48 Carbon Arc Fade Meter Factory Supplier
Get a quote:
Whats/App: +86 156 1874 6768
Web: standard-groups.com
Standards
ISO 11431. ISO 2135;
ASTM D5031. ASTM G151. ASTM G153;
JIS A 1415. JIS A 1439. JIS K 5701-1. AATCC TM16. JIS L 0842. JIS K 6404-4. JIS D 0205. JIS D 0202. JIS E 4037. JIS Z 0237. JIS Z 1528. JIS B 7751;
SAE J2020;
Product Features
High reproducibility and stability
Continuous testing for48 hours
Capable of temperature and humidity control
Irradiance 500W/m2 ±100W/m2 at 300 to 700nm
Specimen Capacity: 102 pcs (65x55x1mm)
Temp. and Hum. range : BPT63±3℃, 35~50±5%rh
Low temp. model U48S with refrigeration system is an option.
High temp. model U48AUH / U48H (BPT95℃) is an option.
Automatic BPT Control model U48AUB / U48B is an option.
BPT Recording model U48AUBR / U48BR is an option.
Technical Parameters
| Parameter | Description |
|---|---|
| Light source | Composed of carbon arcs between upper and lower carbon rods, the arc voltage and arc current can be adjusted according to specific models. For example, some models have an arc voltage of 50V and an arc current of 60A. |
| Filter | Use specific glass filters, such as the Korex 7058 glass filter, to reduce unwanted radiation. |
| Temperature range | The temperature inside the test chamber can be adjusted as needed, usually within a certain temperature range, such as 0-80 °C. |
| Name | UV Fade Meter | |||
|---|---|---|---|---|
| Model | Si48A | Si48 | ||
| Light Source | UV Long-Life Carbon Arc Lamp | UV Long-Life Carbon Arc Lamp | ||
| Light Source Qty. | 1 | 1 | ||
| Continuous Lightning Time | 48 hours | 48 hours | ||
| Irradiance | Wavelength 300 to 700nm | 500±100W/m2 (at 390 to 700nm) |
500±100W/m2 (at 390 to 700nm) |
|
| Test Item | Light | 〇 | 〇 | |
| Light + Spray on front face (Rain) | - | - | ||
| Dark | - | - | ||
| Dark + Spray on back face (Dew) | - | - | ||
| Temperature / Humidity Range |
Light | BPT | 63±3℃ (at 28~30W/m2) | 63±3℃ (at 28~30W/m2) |
| Humidity | 35~50±5%rh | 50%rh or under (not controlled) | ||
| Light + Spray on front face (Rain) |
Chamber Temperature (CAT) | - | - | |
| Dark | Chamber Temperature (CAT) | - | - | |
| Humidity | - | - | ||
| Dark + Spray on back face (Dew) |
Chamber Temperature (CAT) | - | - | |
| Specimen Capacity | excl. black panel sensor and light receptor |
102 (65x55x1mm) | 102 (65x55x1mm) | |
| Specimen Holder | Inclined type | 18 | 18 | |
| Specimen Rack | Diameter | φ508mm (200 in) | φ508mm (200 in) | |
| Rotation Speed | 3 rpm | 3 rpm | ||
| Electrical Specifications | 50/60Hz | Single phase, 200V, 41A | Single phase, 200V, 21A | |
| Earth Leakage Breaker (ELB) | ELB: 50A | ELB: 40A | ||
| Water Consumptions | For wet bulb pot | Tap water | Pure water approx. 7L/h | approx. 0.5L/h |
| For humidifier | Pure water | |||
| For specimen spray | Pure water | - | - | |
| For wall cooling and back spray | Tap water | - | - | |
| For chamber temp. control / refrigerator |
Cooling tower water | - | - | |
| Outer Dimensions | Width x Depth x Height (including pipings) approx. | 95x103x205cm (37.4x40.6x80.7in) | 95x88x175cm (37.4x34.6x68.9in) | |
| Operating Weight | approx. | 300kgs (661lbs) | 280kgs (617lbs) | |
| Standard Accessories | Radiometer for Irradiance Calibration | Optional | Optional | |
| Irradiance Automatic Control System | - | - | ||
| Black Panel Temperature Automatic Control System | Optional | Optional | ||
| Others | - | - | ||
Send product request
Other supplier products
| Oxidizing Solids Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Product Description Conforms to UN Recommendations on the Transport of Dangerous Goods - M... | |
| Fire testing system for large-scale structural safety testing | Whats/App: +86 156 1874 6768 Web: standard-groups.com Application Battery Energy Storage System (BESS) Safety Testing Evaluates fire resistance... | |
| 20L Spherical Explosion Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Product Description: 20L Spherical Explosion Tester is characterized by accurate test data... | |
| Flooring Materials Abrasion Resistance Test device | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standard ASTM D3884(Abrasion Resistance of Textile Fabrics) ISO 5470-1(Rubber or Plastics... | |
| Image test standard transmission light box | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standard CIE 15:2004: Adheres to colorimetry standards for spectral measurement. ISO 3664... |
Same products
| MMA-120 Handheld Arc Welder | Seller: 871183 | The MMA-120 Handheld Arc Welder from ChuangLi Electronic Technology Co., Ltd. is designed for con... | |
| SHX Series Circulating Fluidized Bed Steam Boiler | Seller: Hebei Genjux Boiler Co.,Ltd | Capacity: 10-35 t/hWorking pressure: 1.25-2.5 MPaOperating temperature: 194-400 ℃Applicable to bi... | |
| YQ(Y)W Series Oil/Gas Fired Vertical Thermal Oil Boiler | Seller: Hebei Genjux Boiler Co.,Ltd | Capacity: 7000-29200 KWOperating pressure: 0.8-1.0 MPaOperating temperature: 320℃Operating mode: ... | |
| DHL Series Coal-Fired Steam Boilers | Seller: Hebei Genjux Boiler Co.,Ltd | Capacity: 35-75 t/hOperating pressure: 1.25-5.4 MPaOperating temperature: 194-485℃Applicable to b... | |
| SZL Series Biomass Steam Boiler | Seller: Hebei Genjux Boiler Co.,Ltd | Capacity: 6-35 t/hWorking pressure: 1.0-2.5 MPaOperating temperature: 184-350 ℃Applicable fuel bi... |