ASTM D5865 Oxygen Bomb Calorimeter Manufacturer
Get a quote:
Whats/App: +86 156 1874 6768
Web: standard-groups.com
E-mail:info@standard-groups。com
Parameters
|
Powersupplyvoltage |
AC220V±10%50Hz |
|
Bombcapacity |
(300±50)ml |
|
Oxygenbombpressurerange |
0.5~3.5MPa,noleakage.Thebombpressure21Mpa |
|
AccuracyofTimer |
0.5s |
|
Maximumpower |
0.5KW |
|
Ambienttemperature |
(10~35)ºC |
|
Ambienthumidity |
≤80%RH |
|
Heatcapacityoftheinstrument |
about10000J/K |
|
Heatrepeatabilityerror |
≤0.2% |
|
Temperaturerange |
(4.5-50)ºC |
|
Temperaturedetection |
0.0001ºCresolution,usingthePT100sensor |
|
Innercylindervolume |
2000ml |
|
Motorpower |
3W |
|
stirringspeed |
theinnertube(375r/min) |
Test Procedures
1. Preparation
Before using the building materials combustion value tester, some preparatory work must be done. Identify the building material samples to be tested, prepare the necessary testing tools and materials, and ensure the equipment is functioning properly.
2. Sample Preparation
Cut the building material samples to be tested into appropriate sizes and shapes, ensuring that the surface is flat and free from obvious damage or deformation. Clean the sample surface to remove dust and impurities to avoid affecting the test results.
3. Equipment Operation
a. Turn on the power switch of the building materials combustion value tester, ensuring that the equipment is properly powered. Select the appropriate test mode and parameter settings according to actual needs.
b. Place the sample on the test platform, ensuring a tight fit to prevent air circulation. Start the test program and begin the test. During the test, observe the changes in the instrument data and maintain stable operation of the equipment.
4. Recording and Analysis of Results
After the test is completed, record the relevant data and test results. Analyze and compare the data according to the actual situation. Scientifically interpret the results and draw conclusions. Based on the test results, evaluate the combustion performance of the building materials and determine whether they meet the relevant standard requirements.
Send product request
Other supplier products
| High Precision Contact Lens Oxygen Permeability Analyzer ASTM Standard | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards (1) ISO 18369 – Ophthalmic optics – Contact lenses &nd... | |
| Helmet Webbing Micro - displacement Abrasion Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Main Purposes It is used to detect the abrasion condition of the webbing, the micro - disp... | |
| Automatic oxidizing liquid tester apparatus | Whats/App: +86 156 1874 6768 Web: standard-groups.com Conforms to UN Recommendations on the Transport of Dangerous Goods - Manual of Tests and Cr... | |
| Computer-controlled Helmet Impact Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com A computer-controlled helmet impact tester is an instrument used to test the impact resista... | |
| Metal ring friction and wear testing machine | Whats/App: +86 156 1874 6768 Web: standard-groups.com Evaluate the wear resistance of the material: By simulating the friction process, real-tim... |
Same products
| MMA-120 Handheld Arc Welder | Seller: 871183 | The MMA-120 Handheld Arc Welder from ChuangLi Electronic Technology Co., Ltd. is designed for con... | |
| SHX Series Circulating Fluidized Bed Steam Boiler | Seller: Hebei Genjux Boiler Co.,Ltd | Capacity: 10-35 t/hWorking pressure: 1.25-2.5 MPaOperating temperature: 194-400 ℃Applicable to bi... | |
| YQ(Y)W Series Oil/Gas Fired Vertical Thermal Oil Boiler | Seller: Hebei Genjux Boiler Co.,Ltd | Capacity: 7000-29200 KWOperating pressure: 0.8-1.0 MPaOperating temperature: 320℃Operating mode: ... | |
| DHL Series Coal-Fired Steam Boilers | Seller: Hebei Genjux Boiler Co.,Ltd | Capacity: 35-75 t/hOperating pressure: 1.25-5.4 MPaOperating temperature: 194-485℃Applicable to b... | |
| SZL Series Biomass Steam Boiler | Seller: Hebei Genjux Boiler Co.,Ltd | Capacity: 6-35 t/hWorking pressure: 1.0-2.5 MPaOperating temperature: 184-350 ℃Applicable fuel bi... |