AD3000-TPA Infant Resuscitator
With safe, precise and controllable PIP (Peak Inspiratory Pressure) and PEEP (Positive End Expiratory Pressure), Pigeon Infant Resuscitators are easy to operate and can provide temporaty breathing support. It is crucial for NICU units, Nurseries, Delivery and Transport System.
Working Principle ofPigeon MedicalInfant Resuscitator AD3000-TPA
CPAPneonatal resuscitationalso known as newborn resuscitation is an emergency procedure focused on supporting the approximately 10% of newborn children who do not readily begin breathing, putting them at risk of irreversible organ injury and death. Through positive airway pressure, and in severe cases chest compressions, medical personnel can often stimulate neonates to begin breathing on their own, with attendant normalization of heart rate. Infant resusciatator can deliver a more controlled and consistent peak inspiratory pressure (PIP) and positive end-expiratory pressure (PEEP), which helps to protect the newborn's lungs.
Features of Infant Resuscitator AD3000-TPA
Consistent Care
The easy-to-use T-Piece circuit reduce variations in care, ensuring each breath is delivered in a similar manner.
Do More With Less
Powered by 5L/min, NeoPIP requires less gas flow to operate, for less gas consumed and improved transport range.
Durable & Dependable
Each NeoPIP unit is built to last; a solid case and metal fittings resist damage leading to long service life.
Specification of Infant Resuscitator AD3000-TPA
|
Model |
AD3000-TPA |
|
Pressure gauge |
-2-10kPa(-20-100cmH2O) |
|
PIP |
@5 LPM,2-27 cmH2O |
|
@8 LPM,4-36 cmH2O |
|
|
@10 LPM,6-42 cmH2O |
|
|
@15 LPM,12-57 cmH2O |
|
|
CPCP/PEEP |
@5 LPM,0.3-6 cmH2O |
|
@8 LPM,0.8-14 cmH2O |
|
|
@10 LPM,1-17 cmH2O |
|
|
@15 LPM,2.5-23 cmH2O |
|
|
Noise |
≤50dB(A) |
|
Gas source |
|
|
Recommended patient weightUp to 10KG |
Practical Application of Infant Resuscitator AD3000-TPA
01
Failure to breathe, including antepartum mechanism, recent intrapartum asphyxia, central nervous system depression, maternal drug abuse etc.
02
Failure to expand the lungs, including airway obstruction, respiratory distress syndrome, malformations involving the respiratory tract.
Send product request
Other supplier products
| Y Connector | For most cases of respiratory therapy, the breathing circuit consist of two limbs, one is the inspiration limb and the other one is the expiration ... | |
| Ventilator Circuit Support Arm (Heavy Type) | Ventilator Circuit Support Arm(Heavy Type) Pigeon Medical Circuit Support Arm(Heavy Type) hook can offers ventilator accessories including our uti... | |
| GZ-XRQ-1 Oxygen Inhaler (Oxygen Flowmeter With Humidifier 45-85ml) | We are proud to introduce the Pigeon Medicaloxygen inhaler, which equipped a 1-15LPM flow meter for pediatric and neonatal respiratory care with th... | |
| Adult High Flow Nasal Cannula | Pigeon MedicalNasal Cannula are designed to allow for patients with independent breathing and through provid high-flow, warmed, humidified breathin... | |
| Disposable Breathing Circuit With Heated Wire | Pigeon Medicaldisposable heated wire breathing circuitis made of medical grade polymer materials, non-toxic corrugated hoses which can be widely us... |