Rotatable Sphincterotome
Rotatable sphincterotome is used for cannulation of the ductal system and for sphincterotomy, if preloaded, also aids ERCP operation in the stenosis of bile duct difficult stricture.
Features of Rotatable Sphincterotome
Tapered tip enables easy cannulation.
Insulating coating minimizes the risk of tissue damage as well as endoscopic contact.
Pre-curved tip assists cannulation efficiency and reduce operation time.
Colored markers for precise positioning under endoscopic view.
Double-lumen and triple lumen sphincterotomeare both available.
Preloaded with 0.035" LeadCross.
360° 1:1 rotation facilitates cannulation.
Specification of Rotatable Sphincterotome
Rotatable Sphincterotome
|
REF |
Structure |
Tip Length |
Cutting Length |
Working Length |
Compatible Guidewire |
Minimum Working Channel (mm) |
Unit/Box |
|
standard |
(mm) |
(mm) |
|||||
|
RST0425N |
3-lumen |
4 |
25 |
1900 |
1 |
||
|
RST0430N |
3-lumen |
4 |
30 |
||||
|
RST0725N |
3-lumen |
7 |
25 |
||||
|
RST0730N |
3-lumen |
7 |
30 |
Rotatable Sphincterotome (Preassembled with Guidewire)
|
REF |
Structure |
Catheter |
Tip Length |
Cutting wire Length |
Minimum Working Channel (mm) |
Guide Wire |
Unit/Box |
||||
|
Standard |
Outer Diam. |
Length |
(mm) |
(mm) |
|
Length (mm) |
Tip Shape |
Hardness |
|||
|
(mm) |
(mm) |
||||||||||
|
RST0425NGW0206 |
3-lumen |
1900 |
4 |
25 |
4500 |
Straight |
Normal Stiff |
1 |
|||
|
RST0430NGW0206 |
3-lumen |
1900 |
4 |
30 |
4500 |
||||||
|
RST0725NGW0206 |
3-lumen |
1900 |
7 |
25 |
4500 |
||||||
|
RST0730NGW0206 |
3-lumen |
1900 |
7 |
30 |
4500 |
||||||
|
RST0425NGW0230 |
3-lumen |
1900 |
4 |
25 |
4500 |
Super Stiff |
|||||
|
RST0430NGW0230 |
3-lumen |
1900 |
4 |
30 |
4500 |
||||||
|
RST0725NGW0230 |
3-lumen |
1900 |
7 |
25 |
4500 |
||||||
|
RST0730NGW0230 |
3-lumen |
1900 |
7 |
30 |
4500 |
||||||
Comparison Between a Rotatable Sphincterotome and a Conventional Sphincterotome
The conventional sphincterotome consists of a metal wire with insulating coating, with the distal 20–30 mm of wire exposed, and a short radio-opaque, tapered tip. Cannulation is usually attempted with a sphincterotome at present time. The conventional sphincterotome is designed to perform sphincterotomy at the 12 o'clock orientation, while a rotatable sphincterotome for ERCP in B-II patients or when cannulation/therapeutic interventions entails orientation other than the standard 11–1 o'clock position.
As one of endoscopy device companies, we will do our best to meet all the needs of customers.
Send product request
Other supplier products
| EMR/ESD Accessories | Endoscopic mucosal resection (EMR) and endoscopic submucosal dissection (ESD) are normally performed for removing polyps and early tumorous in the ... | |
| Rotatable Sphincterotome | Leo Medical Co.,Ltd. is committed to providing affordable and qualified endoscope accessoriesin Gastroenterology, Respirology, as well as the medic... | |
| Peripheral Vascular Products | LeoMed Peripheral Vascular productsinclude its three major technology: Balloon catheter Tech., Metalic stent Tech., and Drug loaded Tech., these ke... | |
| PTA Balloon Dilatation Catheter | The PTA dilatation catheteris used for PTA(Percutaneous Transluminal Angioplasty) procedure in the peripheral vasculature, including but not limite... | |
| Single-use Stone Extraction Catheter- RX series | Used for endoscopic removal of biliary stones. Features of Single-use Stone Extraction Catheter- RX series lHigh-quality latex increases the du... |
















