Digital Three Channels ECG RSD903 100% quality assured
NAME Digital Three Channels ECG
STYLE NO RSD903
DESCRIPTIONS ●Digital There Channel ECG Machine;
●Simultaneous 12 leads acquisition;
●Multiple operation mode (Manual /Auto);
●Self-test upon powering on;
●Designed with a high-resolution thermal printer to
print out ECG waveform, annotation as well related parameters for diagnosis reference;
●Digital isolation technology is adopted to minimize time/temperature drift of components so as promote adaptability of the unit to circumstance;
●Digital filter for effective inhabitation of baseline drift, interference, as well automatic position of baseline;
●Function of rhythem lead for observing abnormal ECG waveform and heart rate;
●Automatic measurement and interpretation of ECG waveform to relieve doctors from strain;
●Multiple print formats include 3-channel, 2-channel, 1-channel and particularly the one that combines 3- channel (for lead 1-aVF) and 2-channel (for V1-V6);
●AC/Rechargeable battery for supporting continuous examination when AC power supply is unavailable;
●For battery operation, ECG-903 is equipped with a charger and system for battery capacity management and protection itself from excessive discharge;
●Safety level corresponds to Class I, Type CF.
SPECIFICATION
Lead Standard 12 leads CMMR >60dB
Acquisition Simultaneous 12 leads >100dB(with AC filter)
Resolution 12bit/1000Hz Filter AC filter, EMG filter
Operating Mode Automatic or manual at choice (with measurement report ) Drift filter Anti-Drift System
Recorder High resolution thermal printer
Input Circuit Floating input circuit; Protection against defibrillation and pace making Paper Specification 50x30x20mm,roll
Paper speed 25,50mm/s (±3%)
LCD display Display menu, operation status,
heart rate(digit and words)
Input Circuit Current Isolated ,<=0.1uA
Sampling Rate 1ms Power Supply AC:220V/110V+-10%;50/60Hz+-1Hz,30VA ; DC: 14.4V(1600mAH );
rechargeable Ni-MH battery
Input Impedance >50MQ
Calibration Voltage 1mV±3%
Sensitivity Auto,2.5,5, 10, 20 mm/mV Safety level IEC60601-1 class I , type CF
Time Constant > 3.2 s Dimension and weight 310mm*230mm*70mm
NW 2.5kg
Noise Level <15uVp-p
Frequency Response 0.05-150Hz
ACCESSORIES
Main unit 1 PC; Patient cable 1 PC; Limb electrode 4 PCS; Roll ECG paper 1 roll; Three plugged power cable 1 PCS
Chest electrode 6 PCS; Backup AC fuse 2 PCS; Operating instructions 1 Copy; Earth connecting line 1 PC
Other supplier products