Duodenal Stents
The self-expanding Nitinol stents are used to bypass stenoses in the duodenum. Their spherical ends adapt perfectly to the anatomy of the duodenum, thereby guaranteeing maximum positional stability. Stents with and without covering are available depending on the indication.
The duodenal stent is preloaded on a TTS introducer (through-the scope) as standard. Insertion can therefore be performed through the working channel of the endoscope and the stent can be released under endoscopic observation. X-ray markings on the introducer and on the stent ensure optimum radiological visualisation.
Successful in practical use
The X-ray images show the release process under radiological monitoring. The good radiopacity plus additional X-ray markings on the stent assist orientation and facilitate the release of the duodenal stent. The endoscopic position control clarifies the stent’s optimum expansion.
Duodenal Stents
The self-expanding Nitinol stents are used to bypass stenoses in the duodenum. Their spherical ends adapt perfectly to the anatomy of the duodenum, thereby guaranteeing maximum positional stability. Stents with and without covering are available depending on the indication.
The duodenal stent is preloaded on a TTS introducer (through-the scope) as standard. Insertion can therefore be performed through the working channel of the endoscope and the stent can be released under endoscopic observation. X-ray markings on the introducer and on the stent ensure optimum radiological visualisation.
Successful in practical use
The X-ray images show the release process under radiological monitoring. The good radiopacity plus additional X-ray markings on the stent assist orientation and facilitate the release of the duodenal stent. The endoscopic position control clarifies the stent’s optimum expansion.
Always the appropriate solution
With a diameter of 20 mm and different lengths of 60, 80 or 100 mm, the range of duodenum stents always offers you the right size for your patient.
KEY BENEFITS
Spherical ends
Self-expanding
Nitinol mesh with atraumatic ends
Release under endoscopic observation
Excellent positional stability
Resistant and elastic covering
High radiopacity
Extraction threads for removal and repositioning
Compatible guide-wire up to 0.035 inches
MICRO-TECH (Nanjing) Co., Ltd, is a professional multi band ligator supplier, we provide endoscopy device, duodenal stent insertion, duodenal stent removal, multi band ligator, gastroenterological endoscopy, etc. Want to know more? Please contact us.
Other supplier products
|
Colonic and Rectal Stents |
Positional stability is paramount with colonic stents. MICRO-TECH TTS colonic and rectal stents are known for their ability to anchor safely inside... |
|
Grasping Forceps |
Φ1.8 CoatedGrasping Forceps are used for endoscopic taking out foreign bodies from the human body.
KEY BENEFITS
Adequate forceps opening width... |
|
Sphincterotomes |
Performance Characteristics
Tapered tip
Monofilament cutting wire
KEY BENEFITS
Tapered tip
Monofilament cuting wire
SPECIFICATION
... |
|
EUS FNA Needle |
Details of fna endoscopyneedle
Stainless steel needle ensures good needle flexibility, durability, and target accessibility for standard EUS punctu... |
|
Grasping Forceps |
Φ1.8 Coated
Stone grasping forcepsare used for endoscopic taking out foreign bodies from the human body.
KEY BENEFITS
Adequate forceps ope... |
All supplier products
Same products