MemoPart™ Atrial Septal Defect (ASD) Occluder
MemoPart™
Accurate occluding, stable clamping
MemoPart™ Atrial Septal Defect (ASD) Occluder Details
ASD occluder deviceDescription
MemoPart™ ASD Occluderis a self-expanding double-disc nitinol mesh occlusion device. The 2 discs are connected by a short waist that relates to the defect size. Polyester fabric is securely sewn to each disc to increase occlusion. The device is visible under X-ray.
ASD occluder device Features
Modified rigidity and flexibility for different type of occluders - greater stiffness of Atrial Septal Defect Occluder (ASDO) offers excellent supporting force for big disks.
Uniform and smooth oxide film on nitinol wire effectively prevents from the release of nickel ion to guarantee the great biocompatibility and long-term safety.
The hubless design of Atrial Septal Defect Occluder (ASDO) helps with earlier endothelialization to minimize the risk of thrombosis.
Indications for Use ASD Occlusion Device
The MemoPart™ ASD Occluder is a percutaneous, transcatheter, atrial septal defect closure device intended for the occlusion of atrial septal defects (ASD)in secundum position or patients who have undergone a fenestrated Fontan procedure and who require closure of the fenestration.
Patients indicated for ASD closure have echocardiographic evidence of ostium secundum atrial septal defect and clinical evidence of right ventricular volume overload(i.e.,1.5:1 degree of left-to-right shunt or RV enlargement ).
Ordering Information
Atrial Septal Defect (ASD) Occluder
|
Catalogue No. |
DeviceSiz |
AWaistDiameter(mm) |
B LA Disc Diameter (mm) |
CRA DiscDiameter(mm) |
HWaistLength(mm) |
|
FQFDQ- Ⅰ 06 |
6 |
6 |
16 |
14 |
3 |
|
FQFDQ- Ⅰ 07 |
7 |
7 |
21 |
17 |
3 |
|
FQFDQ- Ⅰ 08 |
8 |
8 |
18 |
16 |
3 |
|
FQFDQ- Ⅰ 09 |
9 |
9 |
23 |
19 |
3 |
|
FQFDQ- Ⅰ 10 |
10 |
10 |
20 |
18 |
3 |
|
FQFDQ- Ⅰ 11 |
11 |
11 |
25 |
21 |
3 |
|
FQFDQ- Ⅰ 12 |
12 |
12 |
22 |
20 |
3 |
|
FQFDQ- Ⅰ 13 |
13 |
13 |
27 |
23 |
3 |
|
FQFDQ- Ⅰ 14 |
14 |
14 |
24 |
22 |
3 |
|
FQFDQ- Ⅰ 15 |
15 |
15 |
29 |
25 |
4 |
|
FQFDQ- Ⅰ 16 |
16 |
16 |
30 |
26 |
4 |
|
FQFDQ- Ⅰ 17 |
17 |
17 |
31 |
27 |
4 |
|
FQFDQ- Ⅰ 18 |
18 |
18 |
32 |
28 |
4 |
|
FQFDQ- Ⅰ 19 |
19 |
19 |
33 |
29 |
4 |
|
FQFDQ- Ⅰ 20 |
20 |
20 |
34 |
30 |
4 |
|
FQFDQ- Ⅰ 22 |
22 |
22 |
36 |
32 |
4 |
|
FQFDQ- Ⅰ 24 |
24 |
24 |
38 |
34 |
4 |
|
FQFDQ- Ⅰ 26 |
26 |
26 |
40 |
36 |
4 |
|
FQFDQ- Ⅰ 28 |
28 |
28 |
42 |
38 |
4 |
|
FQFDQ- Ⅰ 30 |
30 |
30 |
44 |
40 |
4 |
|
FQFDQ- Ⅰ 32 |
32 |
32 |
47 |
42 |
4 |
|
FQFDQ- Ⅰ 34 |
34 |
34 |
49 |
44 |
4 |
|
FQFDQ- Ⅰ 36 |
36 |
36 |
51 |
46 |
4 |
|
FQFDQ- Ⅰ 38 |
38 |
38 |
54 |
50 |
|
|
FQFDQ- Ⅰ 40 |
40 |
40 |
56 |
52 |
|
|
FQFDQ- Ⅰ 42 |
42 |
42 |
58 |
54 |
|
|
FQFDQ- Ⅰ 44 |
44 |
44 |
60 |
56 |
|
|
FQFDQ- Ⅰ 46 |
46 |
46 |
62 |
58 |
|
|
FQFDQ- Ⅰ 48 |
48 |
48 |
64 |
60 |
|
|
FQFDQ- Ⅰ 50 |
50 |
50 |
66 |
62 |
Hubless Atrial Septal Defect (ASD) Occluder
|
Catalogue No. Device |
Device Size |
A Waist Diameter (mm) |
B LA Disc Diameter (mm) |
C RA Disc Diameter (mm) |
H Waist Length (mm) |
|
WTFQFDQ- Ⅰ 06 |
06 |
6 |
16 |
14 |
3 |
|
WTFQFDQ- Ⅰ 07 |
07 |
7 |
21 |
17 |
3 |
|
WTFQFDQ- Ⅰ 08 |
08 |
8 |
18 |
16 |
3 |
|
WTFQFDQ- Ⅰ 09 |
09 |
9 |
23 |
19 |
3 |
|
WTFQFDQ- Ⅰ 10 |
10 |
10 |
20 |
18 |
3 |
|
WTFQFDQ- Ⅰ 11 |
11 |
11 |
25 |
21 |
3 |
|
WTFQFDQ- Ⅰ 12 |
12 |
12 |
22 |
20 |
3 |
|
WTFQFDQ- Ⅰ 13 |
13 |
13 |
27 |
23 |
3 |
|
WTFQFDQ- Ⅰ 14 |
14 |
14 |
24 |
22 |
3 |
|
WTFQFDQ- Ⅰ 15 |
15 |
15 |
29 |
25 |
4 |
|
WTFQFDQ- Ⅰ 16 |
16 |
16 |
30 |
26 |
4 |
|
WTFQFDQ- Ⅰ 17 |
17 |
17 |
31 |
27 |
4 |
|
WTFQFDQ- Ⅰ 18 |
18 |
18 |
32 |
28 |
4 |
|
WTFQFDQ- Ⅰ 19 |
19 |
19 |
33 |
29 |
4 |
|
WTFQFDQ- Ⅰ 20 |
20 |
20 |
34 |
30 |
4 |
|
WTFQFDQ- Ⅰ 22 |
22 |
22 |
36 |
32 |
4 |
|
WTFQFDQ- Ⅰ 24 |
24 |
24 |
38 |
34 |
4 |
Multi-Fenestrated Atrial Septal Defect (ASD) Occluder
|
Catalogue No. |
Device Size |
A Waist Diameter (mm) |
B LA Disc Diameter (mm) |
C RA Disc Diameter (mm) |
H Waist Length (mm) |
|
FQFDQ- Ⅱ 06 |
6 |
6 |
30 |
22 |
3 |
|
FQFDQ- Ⅱ 08 |
8 |
8 |
32 |
24 |
3 |
|
FQFDQ- Ⅱ 10 |
10 |
10 |
34 |
26 |
3 |
|
FQFDQ- Ⅱ 12 |
12 |
12 |
36 |
28 |
3 |
|
FQFDQ- Ⅱ 14 |
14 |
14 |
38 |
30 |
3 |
|
FQFDQ- Ⅱ 16 |
16 |
16 |
40 |
32 |
4 |
|
FQFDQ- Ⅱ 18 |
18 |
18 |
42 |
34 |
4 |
|
FQFDQ- Ⅱ 20 |
20 |
20 |
44 |
36 |
4 |
|
FQFDQ- Ⅱ 22 |
22 |
22 |
46 |
38 |
4 |
|
FQFDQ- Ⅱ 24 |
24 |
24 |
48 |
40 |
4 |
Hubless Multi-Fenestrated Atrial Septal Defect (ASD) Occluder
|
Catalogue No. |
Device Size |
A Waist Diameter (mm) |
B LA Disc Diameter (mm) |
C RA Disc Diameter (mm) |
H Waist Length (mm) |
|
WTFQFDQ- Ⅱ 06 |
6 |
6 |
30 |
22 |
|
|
WTFQFDQ- Ⅱ 08 |
8 |
8 |
32 |
24 |
|
|
WTFQFDQ- Ⅱ 10 |
10 |
10 |
34 |
26 |
|
|
WTFQFDQ- Ⅱ 12 |
12 |
12 |
36 |
28 |
|
|
WTFQFDQ- Ⅱ 14 |
14 |
14 |
38 |
30 |
As one of medical devices suppliers, we can offer sorts of medical devices chinafor sale, anything you need, please leave us a message.
Send product request
Other supplier products
| Fingertip Pulse Oximeter | Lepu Medical Technology ( Beijing ) Co., Ltd was established in 1999. As a professional lepu medical technologygroup, it is specialized in developi... | |
| Hoper™ PTCA Balloon Dilatation Catheter | To develop LepuMedical into one of the largest cardiovascular products manufacturersand on the platforms of medical device, medicine, healthcare pr... | |
| MemoPart™ Patent Ductus Arteriosus (PDA) Occluder | MemoPart™ Multiple designs, anastomosing lesions MemoPart™ Patent Ductus Arteriosus (PDA) Occluder Details Product Description MemoP... | |
| Oximeter | Used to measure the arterial oxygen saturation, fingertip oximeters are a must-have medical devices to mesure important parameters of patient's con... | |
| Methyl 3-oxovalerate | Methyl 3 Oxovalerate Item/Code CAS No. Therapeutic Area Certification/Stage INT 30414-53-0 Comme... |
Same products
| R404a Scroll Compressor for Cold Chain Transportation | Seller: Shanghai LeLing New Energy Technology Co., Ltd. | Optimized for Cold Chain Vehicles & Containers The34cc R404a scroll compressor for cold chai... | |
| Electric scroll compressor with R404a Refrigerant | Seller: Shanghai LeLing New Energy Technology Co., Ltd. | Introduction Leling's compact refrigeration scroll compressor (18CC) is specially engineered for... | |
| Vapor Injection Compressor With Enhanced Enthalpy | Seller: Shanghai LeLing New Energy Technology Co., Ltd. | The vapor injection compressor with enhanced enthalpy is a new type of compressor improved on the... | |
| R404a Refrigeration Compressor | Seller: Shanghai LeLing New Energy Technology Co., Ltd. | R404a Refrigeration Compressor The refrigeration and freezing scroll compressor is a type of com... | |
| DC variable frequency electric scroll compressor | Seller: Shanghai LeLing New Energy Technology Co., Ltd. | The electric scroll compressoris mainly composed of moving scroll plate, stationary scroll plate,... |