.

Pump and Valve Contamination Tolerance Tester

Meet the standard:

ISO 4406 ISO 18413

ISO 10707 ISO 6403

ISO 10372 NFPA T2.6.1

Product Introduction:

Solid particle contamination is a major cause of wear, silting, stiction, leakage, and ultimately failure in hydraulic pumps and valves. A Pump and Valve Contamination Tolerance Tester provides a controlled environment to subject both component types to contaminated fluid and assess their performance over time.

The tester typically consists of a hydraulic test circuit where the pump(s) and valve(s) under evaluation are installed. A reservoir holds a volume of test fluid (hydraulic oil) which is intentionally contaminated with a specific type and concentration of solid particles. The pump circulates this contaminated fluid, and the system includes a loading mechanism (e.g., restrictors, actuators) to operate the pump and cycle the valve(s) under realistic pressure, flow, and temperature conditions.

Throughout the test, which may involve running for extended durations or millions of cycles, the performance of both the pump and the valve(s) is monitored. Pump performance measurements include flow rate (volumetric efficiency), pressure, speed, and potentially power consumption. Valve performance measurements vary depending on the valve type (directional control, pressure control, flow control) but can include leakage rate, pressure control accuracy, flow regulation accuracy, response time, and the force or current required to shift spools. The cleanliness level of the circulating fluid is continuously or periodically verified using fluid sampling and particle counting according to standards like ISO 4406. After the test, component performance is re-measured, and the pump and valve(s) are often disassembled for detailed visual inspection and quantitative measurement of wear on critical surfaces. This comprehensive evaluation provides crucial data on how contamination affects the operational lifespan and performance stability of both pumps and valves.

The instrument is used for:

Evaluating the wear resistance and durability of hydraulic pumps and valves simultaneously under contaminated fluid conditions.

Determining the impact of fluid contamination on the performance characteristics (efficiency, leakage, control accuracy, response time) of pumps and valves over time.

Validating the contamination tolerance of pump and valve designs, materials, and manufacturing processes.

Benchmarking the contamination resistance of different pump and valve models or manufacturers.

Research and development of more robust hydraulic components for use in contaminated environments.

Assessing the effectiveness of design modifications in improving contamination tolerance.

Product Advantages:

Provides a comprehensive evaluation of both hydraulic pump and valve performance and wear resistance in a single test setup under contaminated conditions.

Simulates the interaction of contaminated fluid with key components in a hydraulic circuit.

Essential for selecting pumps and valves that can reliably operate in hydraulic systems with expected levels of fluid contamination.

Helps validate component designs and materials specifically for resistance to wear and degradation caused by particles.

Provides objective, quantitative data on the long-term effects of contamination on pump and valve performance.

Supports research and development efforts aimed at improving the robustness and lifespan of hydraulic components.

Technical indicators:

  1. Test medium: hydraulic oil

  2. Temperature of medium: 10~80℃.

  3. Test dust: ISO 12103-A3

  4. Test pressure range: 0.5 ~ 6MPa

  5. Test flow: 1~20 L/min

  6. Purification cleanliness: -/12/10 (GB/T

  7. Test tank volume: 40L

  8. Execution standard: JBT 7857-2006

  9. Equipment power supply: AC380V / 50Hz

  10.Power of the whole machine: 5.5kW


Send product request

To: Standard International Group (HK) Limited
Your E-mail:
Message text:


Send to other suppliers

Other supplier products

Bone Screw Static  Torque Testing Machine
Bone Screw Static Torque Testing Machine Standard YY/T 0591-2011: Chinese standard specifying torsion testing methods for intramedullary nails, including torque application, angular dis...
HapLog Finger Tactile Sensor
HapLog Finger Tactile Sensor HapLog sensor is a “sensor that measures natural finger operations” with a built-in contact force sensor and a 3-axis acceleration sens...
Paper quantitative tester
Paper quantitative tester Product Information: The circular square quantitative sampler (referred to as quantitative sampler) is a special sampler for the quantitative dete...
PV Hail Impact Tester/ IEC 61215 hail test equipment/ Ice ball impact tester
PV Hail Impact Tester/ IEC 61215 hail test equipment/ Ice ball impact tester 1. Standard Compliance IEC 61215: Mechanical load testing for terrestrial photovoltaic modules. UL 61730: Safety standards for photovoltaic mod...
Dry microbial penetration tester
Dry microbial penetration tester Standards: ISO 22612 YY/T 0506.5 Applications: Dry microbial penetration resistance tester DMPRT is to assess the penetration resistance t...
All supplier products

Same products

pH-2398  pH/EC/ORP/Temperature  multi-parameter Water Quality Tester
pH-2398 pH/EC/ORP/Temperature multi-parameter Water Quality Tester Seller: Kelilong Electron Co.,Ltd Feature Large display screen, capable of simultaneously measuring water quality pH, redox potent...
ORP-2026S  Waterproof Soil ORP and Temperature Meter
ORP-2026S Waterproof Soil ORP and Temperature Meter Seller: Kelilong Electron Co.,Ltd 范围 ORP -999~999mV Temp 0~50℃ 分辨率 ORP 1mV...
TDS-2616  Waterproof EC/TDS/Temperature Meter
TDS-2616 Waterproof EC/TDS/Temperature Meter Seller: Kelilong Electron Co.,Ltd Range EC ~19.9mS TDS Temp 0~50℃ R...
EC-98330 CF ECOstick - Nutrient Tester
EC-98330 CF ECOstick - Nutrient Tester Seller: Kelilong Electron Co.,Ltd Ideal for hydroponics and agriculture applications, theNutrient Tester accurately measures the el...
PH-808 Waterproof Soil PH Meter
PH-808 Waterproof Soil PH Meter Seller: Kelilong Electron Co.,Ltd Model PH-808 Range PH ~14.00PH Temp 0~50℃ ...