Mask BFE Testing Machine
Mask BFE Testing Machineis used to test the percentage of material containing bacterial suspended particles at a specific flow rate.
Features:
1. MaskBFE Testing Machine: negative pressure test system, can protect the safety of the operator.
2. Peristaltic pump built in the negative pressure cabinet,A, B channel 28.3L/min.
3. The flow rate of the peristaltic pump can be set.
4. BFE Tester atomization effect is good.
Mask BFE Testing Machinetest principle:
Bacterial filtration efficiency Tester consists of aerosol generation system, aerosol chamber and aerosol transmission device, negative pressure cabinet, 28.3 l/min carbon sampler and other components.The entire detector is controlled by the console.The console adopts microcomputer control system to coordinate and control the work of aerosol generating system, transmission system, negative pressure cabinet and sampling system, and display the working status in real time.The entire measurement work is done automatically.
Applicable Standards
- ASTM F2100 standard specification for performance of materials used in medical face masks
- EN 14683standard that medical face masks in Europe are required to comply with
- ASTM F2101 standard test method for evaluating bacterial filtration efficiency (BFE) of medical mask materials using Staphylococcus aureus biological aerosol
- YY0469-2011Technical requirements for surgical mask
- YY/T 0969-2013Single-
use medical face mask
Technical Specification:
Conforms to EN 14683 and ASTM F2101
A Route Sampling Flow: 28.3L/min, resolution 0.1, E±2.O% L/min
B Route Sampling Flow: 28.3L/min, resolution 0.1, E±2.O% L/min
Spray Flow: (O.l e?? 10)L/min, resolution 0.1, E±5.O% L/min
Peristaltic Pump Flow: (0.001 ? 3.O)mL/min, resolution 0.001, E±2.O%
Negative Pressure Chamber: (-90 ? -120)Pa, resolution 0.1, E±I.O%
Working Temperature: OOC to 500C
High Efficiency Particulate Air Filter Properties:
Diameter of aerosol generator mass: Average diameter:
(3.0+0.3)fm; Geometric Standard Deviation<1.5pm
Double Routes 6-lever Andersen Sampling apparatus:
Level l: >7gm; Level Il: (4,7 to 7)gm; Level Ill: (3,3 to 4.7)gm;
Level IV: (2.1 to 3.3)gm; Level V: (1.1 to 2.1)gm;
Level VI: (0.6 to 1.1)gm
Total number of positive quality control sampler particles: (2200±500)cfu
Negative Chamber Flow Speed: 25m/min
Size of Aerosol Chamber: at least (600x80x3) mm
Power supply: 220 V AC, 60 1-Iz
Noise: 65db(A)
Characteristics of G299Mask BFE Testing Machine:
1. Intelligent touch screen control panel
more efficient and reliable, programmable 10 inch colorLCD touch, achieve control, data display and other functions
2. High precision
Two samplers simultaneously sampling, avoid the test errorby intermediate link, improve the accuracy of test
3. Multi directional protection design
Equipped with current overload protection, leakage protectionand negative pressure cabinet to ensure safety for operator
4. Stability customized parameters
Adopts imported accessories, features stable movements,accurate test data and good repeatability
Applications ofbacterial filtration efficiency tester:
Mask BFE Testing Machineis used to detect the filtration efficiency of masks, and also can be used for measurement and calibration departments, scientific research institutions, mask production enterprises and other relevant departments.
Send product request
Other supplier products
| Scorch Tester Sublimation fastness tester | In the daily process of shaping and high temperature ironing, dyes heat stability will affect the appearance of fabrics.. Dyes heating , heat trans... | |
| Thrust Bearing Rolling Friction and Wear Testing Machine | Applicable Standards: ASTM D3702 ASTM G99 ASTM G77 ISO 18535 Product Advantages: Simulates Real-World Conditions: Allows testing under cont... | |
| Mulfunctional Scratch Tester | Standards: GB/T 2918. GB/T 6151. GB/T 8424.3. PV3952. BMW GS97034-2. BMW GS97034-9. GMN 3943-2003.FLTM BN 108-13.STD1024-3113.GMW 14698-A,GMW 1468... | |
| Metal ring friction and wear testing machine | Evaluate the wear resistance of the material: By simulating the friction process, real-time monitoring of friction, temperature, wear and other pa... | |
| MARK-II Slip Resistance Tester | Product Introduction: Paste the cut sample on the test fixture of the portable MARK-II anti-slip testing machine, put down the weight of the rotat... |
Same products
| Full-Body Garment Stress Tester,FZ/T 70015 | Seller: Standard International Group (HK) Limited | TheFull-Body Garment Stress Testeris a precision instrument designed to quantify the pressure exe... | |
| Industrial Dry Cleaning Machine,industrial garment steamer | Seller: Standard International Group (HK) Limited | TheIndustrial Dry Cleaning and Energy-Saving Dryer Machinesare designed for high-performance, rel... | |
| MST Medical Compression Stocking Tester,compression sock tester | Seller: Standard International Group (HK) Limited | The MST Medical Compression Stocking Tester is a professional instrument designed to evaluate the... | |
| MMT Liquid Water Separation Tester,MMT Liquid Water Analysis Tool | Seller: Standard International Group (HK) Limited | Applications Textile Manufacturing:Testing waterproof fabrics for outdoor gear R&D:Developi... | |
| Dental material color stability tester | Seller: Standard International Group (HK) Limited | Application The applications of color stability testers for dental materials are mainly reflecte... |