Catheter Airflow Resistance Tester
The Catheter Airflow Resistance Tester is a precision testing instrument specifically designed for measuring the airflow resistance of catheters.
Applications
The catheter airflow resistance tester is an important tool for evaluating the resistance of gas flow in catheters. It is specifically designed to measure the airflow resistance inside medical devices such as breathing catheters. It is widely applied in multiple fields, including medical care, environmental protection, and the chemical industry. Especially in the production and quality - control processes of medical devices, this tester plays a crucial role. Through testing, it can ensure that catheter - related products like breathing tubes can meet the predetermined performance standards, thereby improving the overall product quality and production efficiency. In the medical field, the tester is used to assess the performance of breathing circuits for anesthesia machines and ventilators, ensuring that the products meet relevant standards and requirements.
Standards
YY0461 - 2003:Technical Requirements for Protective Masks for Medical Use
Features
Embedded Linux operating system, secure, efficient, and durable.
Get both English and Chinese input capabilities for the same price.
Non-standard customized services to create exclusive equipment tailored to your company.
Expand to various testing projects by changing dedicated custom fixtures.
Personalized input of production units and batches to obtain original production reports.
Processing speed up to 72MHz per second, testing resolution improved to 0.0001.
Touchscreen control for easier operation and more intuitive data display.
Multiple specifications, one machine compatible with various applications, automatic generation of test reports.
Onboard printer for quick printing of test results.
Real-time display of test pressure values, automatic power off in case of overload, and automatic data storage upon power failure.
Three-level password protection for secure and reliable information.
Technical Parameters
| Parameter | Specification |
|---|---|
| Pressure Measurement Range | Usually 0.01kPa to 10kPa; error ≤ ±1%; display resolution: 0.01kPa. This range covers airflow resistance measurement requirements for most catheters. |
| Flow Measurement Range | Typically 0L/min to 50L/min (varies by tester model), enabling airflow resistance testing of catheters under different flow conditions. |
| Test Duration | Usually 1 second to 10 minutes; error ≤ ±1 second. This range ensures test accuracy and stability. |
| Accuracy | Pressure measurement accuracy: ±0.01kPa; flow measurement accuracy: ±2.5% (or lower, depending on specific model). |
Accessoriess
Standard accessories: Dedicated clamps/connectors for different diameter tubes, airflow connecting tubing, sensor calibration parts, operating manual, and calibration certificate.
Optional accessories: Sample fixing bracket (for assisting tube installation), data export cable (for some models).
Test Procedures
1. Preparation
Ensure the instrument is in normal working condition and check that the power cord, sensors, and other components are intact. Connect the tubing and ensure a good seal between the tubing and the instrument interface.
2. Setting Parameters
According to the test requirements, set the relevant parameters of the instrument, such as flow rate and pressure measurement range.
3. Starting the Test
Start the instrument to begin the test. The instrument will automatically inject gas into the tubing and measure the pressure difference between the inlet and outlet. Based on the measurement results, the instrument will calculate the airflow resistance of the tubing.
4. Data Recording and Analysis
After the test is completed, the instrument will output the test results. The operator should carefully record this data and analyze it to evaluate the performance of the tubing.
Send product request
Other supplier products
| Solid Combustion Rate Tester | Product Introduction This product complies with "Recommendations on the Transport of Dangerous Goods - Manual of Tests and Criteria" 33.2.1.4 Test... | |
| Friction and wear testing machine | Standards ASTM G99-04 ASTM G77-16 ISO 9352:1995 GB/T 12444-2006 GB/T 12607-2007 GB/T 1865-2009 Application field Petrochemical: Used to ass... | |
| Safety Helmet Impact Acceleration Tester | The safety helmet impact acceleration tester is an instrument used to test the performance of safety helmets when subjected to impact. It can simul... | |
| Absorbable Bone - connecting Plates Four - point Bending Tester | Standard ASTM F2119: Standard test method for constant load testing of bioabsorbable screws and washers, applicable to bending performance evalu... | |
| Model Coin-cell Swelling System | The Model Coin-Cell Swelling System is designed for in-situ measurement of thickness and volume changes of coin-type lithium-ion cells during charg... |
Same products
| Gas Oxidizing Property Tester | Seller: Standard International Group (HK) Limited | Product Description Conforms to ISO 10156-2010 “Gases and Gas Mixtures Selection of Cylind... | |
| Battery Powder Compaction Density Measurement System | Seller: Standard International Group (HK) Limited | The Battery Powder Compaction Density Measurement System is a precision testing system designed... | |
| Battery Powder resistance tester | Seller: Standard International Group (HK) Limited | The Powder Resistivity Meter is a precision testing system designed to measure electrical resisti... | |
| KES-SESRU surface roughness/friction tester | Seller: Standard International Group (HK) Limited | TheRoughness/Friction Tester analyzes hand movements-particularly, strokes-performed by artisans ... | |
| Air Permeability Tester STD- F8 | Seller: Standard International Group (HK) Limited | The Air Permeability Tester is designed to quickly and accurately measure the breathability and p... |