Direcct flame impingement Tester
Whats/App: +86 156 1874 6768
Web: standard-groups.com
Introduction
The testerisdesignedaccording to the BS476-12:1991.Method of test for ignitability of products by direct flame impingement.The accuracy of the tester meets the requirements of relevant standards and meets the control requirements for the accuracy of measurement.
Standards
BS 476-12
Structure
1.Voltage:220V + 10%, 50Hz;
2.Burner.
(1)Ignition source D. A gas burner comprisinga 185 mm long horizontal stainless steeltube(12.0 mm outside diameter, 9.0 mm insidediameter) closed at each end and fitted with acentral gas supply pipe. The burner tube shall havea row of 14 holes of 1.5 mm diameter at 12.5 mmcentres arranged so that the gas jets issue at anangle of 45 below the horizontal.
Theflowmeter shall be calibrated to supply a propanegas flow rate at 25C of 2 l/min
NOTE: Under these conditions the flame height isapproximately 240 mm.
(2)Ignition source E. a gas burner comprisinga 185 mm long horizontal stainless steeltube(12.0 mm outside diameter, 9.0 mm insidediameter)closed at each end and fitted with acentral gas supply pipe. The burner tube shall havea row of 14 holes of 1. 5 mm diameter at 12.5 mmcentres arranged so that the gas jets issue at anangle of 45 below the horizontal.
3.Aburner carriage consisting of a movablecolumn which incorporates a 10 mm On x 1 mmwall stainless steel tube terminated by athreaded boss to which the various burners canbe fixed.
4.A length of 5 mm internal diameter hose not greater than 3.0 m in length to connect the flowmeters to the burner carriage via a gas cock mounted on the carriage.
5.Test frame. A horizontal steel platform to whicha sliding burner carriage and burner tube areattached. At one end of the platform, means shall beprovided to maintain the specimen holder in avertical position.
6.Specimen holder. The vertical specimen holdershall be capable of accommodating the largest size ofspecimen Specimens shall be gripped at intervalsalong both vertical edges.
For narrower specimens, holders may be designed tofit within the widest holder in order to provide acommon position for testing.
7.Burner carriage and tube. The ignition source shall be mounted on a burner support tube fitted to the burner carriage(see Figure 1). The tube shall be equipped with means to allow vertical adjustment of the ignition source position as required by the various tests. The burner carriage shall be designed in such a way that the distance between the burner and the specimen is obtained accurately. reproducibly and automatically and manufactured so that the ignition source can be brought into the prescribed position smoothly and within 1s.
8.A clamp used to fix the soft wood。
9.Draught shields. Draught shields of 9 mm thicknon-combustible board, triangular in shape, with abase of approximately 500 mm andapproximately 750 mm in height shall be providedfor use with ignition sources A. B and C.
Parameters
1.Propane flow:10-1000±5 mL / min,
2.Air flow:0-100L/min
3.Burning angle:45and90º;
4.Various test parameters can be set directly on touch screen.。
5.Control: touch screen +PLC control
6.Test time: 1-99minsarbitraryset.
Gas and air system
1.Gas (customerprepared)
(1)Propane and LPG。
(2)Air supply pipe, compression release valve, safety valve.
2.Air source system (customerprepared)
(1)Compressed air: 0-6kgf
(2)Switch valve and pressure gauge
Send product request
Other supplier products
| laboratory fabric negative ion concentration analyzer manufacturer | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications Functional Textile R&D: Assesses air-purifying, health-enha... | |
| Vertical Computer Control Universal Friction And Wear Testing Machine | Whats/App: +86 156 1874 6768 Web: standard-groups.com Application (1) Research and development in tribology and material sciences. (2) Friction... | |
| White Light Interferometer for Surface Topography Measurement | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards The White Light Interferometer supports surface measurement and analysis methods... | |
| Respirator Fit Test meter | Whats/App: +86 156 1874 6768 Web: standard-groups.com PortaCount Respirator Fit Tester: Qinsun assesses the overall integrity of masks by perfor... | |
| Fiber Crimp Elasticity Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com The Fiber Crimp Elasticity Tester is a specialized instrument designed to measure the crimp... |
Same products
| Full-Body Garment Stress Tester,FZ/T 70015 | Seller: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com TheFull-Body Garment Stress Testeris a pr... | |
| Industrial Dry Cleaning Machine,industrial garment steamer | Seller: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com TheIndustrial Dry Cleaning and Energy-Sav... | |
| MST Medical Compression Stocking Tester,compression sock tester | Seller: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com The MST Medical Compression Stocking Test... | |
| MMT Liquid Water Separation Tester,MMT Liquid Water Analysis Tool | Seller: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications Textile Manufacturing:Testi... | |
| Dental material color stability tester | Seller: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Application The applications of color st... |