PTA Balloon Dilatation Catheter
Leo Medical Co.,Ltd. is committed to providing affordable and qualified endoscope accessoriesin Gastroenterology, Respirology, as well as the medical devices used in PAD. LeoMed’s industry related R&D ability, and stable supply chain ensure its commitment to the end users.
PTA Balloon Dilatation Catheter
The PTA Balloon Dilatation Catheter is indicated for PTA percutaneous transluminal angioplastyin the peripheral vasculature, including but not limited to iliac, femoral, popliteal arteries and for the treatment of obstructive lesions of native or synthetic arteriovenous dialysis fistulae. It's also indicated for post-dilatation of balloon-expandable and self-expanding stents in the peripheral vasculature.
Features of PTA Balloon Dilatation Catheter
Low profile balloon design provides good crossability. Hydrophilic coating reduces friction.
Soft and tapered tip design minimize trauma and ensure transition to the wire smoothly.
Robust catheter optimizes the pushability.
Diameters range from 3.0 - 14.0 mm and lengths up to 200 mm, allowing optimal choice of balloon.
Specification of PTA Dilatation Catheter
Lower Limb Artery
|
REF |
Balloon |
Catheter Length (cm) |
Min Working Channel(F) |
Compatible Guidewire (in) |
Units/Box |
|||
|
Length(mm) |
NP(atm) |
RBP(atm) |
||||||
|
L10A030100 |
3 |
100 |
8 |
14 |
90 |
5 |
1 |
|
|
L10A030150 |
3 |
150 |
8 |
14 |
90 |
5 |
||
|
L10B030100 |
3 |
100 |
8 |
14 |
150 |
5 |
||
|
L10B030150 |
3 |
150 |
8 |
14 |
150 |
5 |
||
|
L10C040100 |
4 |
100 |
8 |
14 |
80 |
6 |
||
|
L10C040150 |
4 |
150 |
8 |
14 |
80 |
6 |
||
|
L10C050100 |
5 |
100 |
8 |
14 |
80 |
6 |
||
|
L10C050150 |
5 |
150 |
8 |
14 |
80 |
6 |
||
|
L10D040100 |
4 |
100 |
8 |
14 |
135 |
6 |
||
|
L10D040150 |
4 |
150 |
8 |
14 |
135 |
6 |
||
|
L10D050100 |
5 |
100 |
8 |
14 |
135 |
6 |
||
|
L10D050150 |
5 |
150 |
8 |
14 |
135 |
6 |
||
Upper Limb AVF
|
REF |
Balloon |
Catheter Length (cm) |
Min Working Channel(F) |
Compatible Guidewire (in) |
Units/Box |
|||
|
Length(mm) |
NP(atm) |
RBP(atm) |
||||||
|
L10C050040 |
5 |
40 |
8 |
14 |
80 |
6 |
1 |
|
|
L10C050060 |
5 |
60 |
8 |
14 |
80 |
6 |
||
|
L10C060040 |
6 |
40 |
8 |
14 |
80 |
6 |
||
|
L10C060060 |
6 |
60 |
8 |
14 |
80 |
6 |
||
Lower Limb Vein
|
REF |
Balloon |
Catheter Length (cm) |
Min Working Channel(F) |
Compatible Guidewire (in) |
Units/Box |
|||
|
Length(mm) |
NP(atm) |
RBP(atm) |
||||||
|
L10C120100 |
12 |
100 |
8 |
10 |
80 |
8 |
1 |
|
|
L10C140080 |
14 |
80 |
7 |
9 |
80 |
9 |
||
|
L10D120100 |
12 |
100 |
8 |
10 |
135 |
8 |
||
|
L10D140080 |
14 |
80 |
7 |
9 |
135 |
9 |
||
Send product request
Other supplier products
| Single-Use Airway Retrieval Basket | This bronchoscopic basketis used for endoscopic removal of foreign bodies from airway. Features of Single-Use Airway Retrieval Basket 4 wires... | |
| Single-use Injection Therapy Needle Catheter | Endoscopic injection needleis used for endoscopic submucosal injection and hemostasis. Features of Single-use Injection Therapy Needle Catheter ... | |
| Single-use Stone Extraction Catheter | Stone extraction balloonis used for endoscopic removal of biliary stones. Features of Single-use Stone Extraction Catheter High-quality latex incr... | |
| Single-use Biliary Draining Tubing | LeoMed, a professional endoscopy accessories manufacturer, established by returnee in 2011, dedicated to developing and producing cost-effective, h... | |
| Sphincterotome - RX series | Used for cannulation of the ductal system and for sphincterotomy, if preloaded, also aids ERCP operation in the stenosis of bile duct difficult str... |

















