ZY series ultrasonic calorimeter
ZY-CHouseholdUltrasonicHeatMeter
ZYseriesultrasonicheatmeteroperateswithultrasonicflowtransducerincombinationwithpairedtemperaturesensorformeasuringsupplywaterflowrateandthetemperaturedifferencebetweensupplywaterandreturnwater,andthenmeasuresanddisplaystheheatqualityeitherreleasedorabsorbedbythewaterflowingthroughaheatexchanger.Itcanexecuteflowratemeasurement-computation-displayintegratedfunctions.Compactinsizewithultra-lowpowerconsumption,themeterissuitableforresidentialbuilding,districtheatingsystemandcentralizedairconditioningsystem.
Thesquareholestraightthroughheatmeterworkswithultrasonicflowratemeasurementtechnologyremediallyinthecasewherethewaterhasahighcontentofimpurities.Furthermore,withtheuseofthemeter,thepressurelossofpipelinecanbereducedtoaminimum.Themetercanbemountedatanyangleineitherhorizontalorverticaldirection.
Technicalspecifications:
Capability |
Parameter |
|||||||
NominalDiameter(mm) |
DN15 |
DN20 |
DN25 |
DN32 |
DN40 |
|||
Ratedflow(m³/h) |
2.5 |
6 |
10 |
|||||
MinFlow(m³/h) |
|
|||||||
MaxFlow(m³/h) |
12 |
20 |
||||||
TemperatureRange |
4~95ºC |
|||||||
TemperatureDifference |
3~90K(Minvalueofex-factoryis0.2) |
|||||||
MinTemperatureErrorPair |
±0.1 |
|||||||
Workingpressure |
||||||||
Pressureloss |
≤10kPa/straightthroughpipewithnoreflectioncomponent |
|||||||
Accuracy |
EN1434/CJ128Class2 |
|||||||
TypeofFlowSensor |
Ultrasonicflowsensor |
|||||||
TypeofTemperatureSensor |
PT1000 |
|||||||
ProtectionClass |
IP65 |
|||||||
PowerSupply |
Dualpowersupplywithlithiumbattery(withservicelifeover6years)andremotetransmissionpowersupply. |
|||||||
Maxstaticcurrent |
10μA |
|||||||
Masworkingcurrent |
40μA |
|||||||
AmbientClass |
EN1434/CJ128ClassA |
|||||||
CommunicationMode |
M-BUS,Rs485,infraredopticalinterface |
|||||||
Display |
8-digit+promptingcharacter |
|||||||
Cumulativeheatquantity:kWhorMJ(DisplayRange:0~9999999.9) Thermalpower:KW |
||||||||
Instantaneousflowrate:m³/h Totalvolume:m³ Supplyandreturnwatertemperature:ºCTemperaturedifference:K Totaloperatingtime:h |
||||||||
Date:Y/M/D,Clock:h/m/s |
||||||||
DisplayResolution |
Heatquantity:0.1kWhor1MJ Totalvolume:0.001m³ Temperature:0.01ºCTemperaturedifference:0.01K |
|||||||
DataStorage(EEPROM) |
Heatquantity,totalvolumeandcorrespondingtime,maxthermalpowerofthecurrentmonthstoredbymonth.Latest18month’sdatacanbestored. |
|||||||
Mountingposition |
Supplyorreturnpipe |
|||||||
Mountingmode |
Vertical,horizontal |
|||||||
Connectingtype |
Threadedpipe |
Send product request
Other supplier products
ZY no baffle-board ultrasonic heat meter | Features: Splitinstallation Canbedismountedforcleaningandmaintenance Convenientforverifyingandcalibratingagainafterusage Goodinstallationadaptabil... | |
detachable split mechanical energy meter | Features: Splitinstallation Canbedismountedforcleaningandmaintenance Convenientforverifyingandcalibratingagainafterusage Goodinstallationadaptabi... | |
ZY series ultrasonic calorimeter | ZY-CHouseholdUltrasonicHeatMeter ZYseriesultrasonicheatmeteroperateswithultrasonicflowtransducerincombinationwithpairedtemperaturesensorformeasurin... | |
No baffle-board ultrasonic heat meter | Structure ·Flowsensor:straightthroughtypeinwallreflectionultrasonicflowsensorwithnoreflectionplatestandandbeampieces ·Temperaturese... | |
Household Ultrasonic heat meter | ZY-Cultrasonicheatmeterconsistsofflowsensor,temperaturesensorandcalculatorandissimpletoinstall,readandverify.Itisidealforthemeasurementofenergycons... |