No baffle-board ultrasonic heat meter
- Structure
·Flowsensor:straightthroughtypeinwallreflectionultrasonicflowsensorwithnoreflectionplatestandandbeampieces
·Temperaturesensor:PT1000temperaturesensorpair
·Opticalinterface,M-businterfacefordatacommunication
- Flow
- Ratedflow:1.5~3.5m³/h
- Ratedflowandminflowproportionis100.
- Temperatureandtemperaturedifference
- Temperaturemeasurementrange:4~95℃
- Temperaturedifference:3~90℃
- Thermalcoefficient:Alongwithinletandoutletwater
- Connectionmode
- Installationposition:inletoroutletasinstructed(optional)
- Connectiontype:threadedconnection
- Maxworkingpressure:1.6MPa
- Servicecondition
- Environmentcondition:ClassA
- Display
- Display:LCD,8digits,specialsymbols
- Dimension:kWh,MJ
- Resolution
(1)Heat:1kWhor1MJ
(2)Cumulativeflow:0.01m³
(3)Temperature:0.1℃
(4)Temperaturedifference:0.1K
- Datastorage
- Datastorage:ROM
- Storeatleast18months’data
- Intensityandtightness
- Nodamageandleakagewhenthemediumtemperatureis10℃lessthanthemaxworkingtemperatureandthepressureis1.6timesgreaterthanthemaxworkingpressure.
- Accuracy
- MeteringaccuracyisClass2
- Pressureloss
- Pressureloss<10kPa(Industrialstandard:Maxallowedpressurelossis25kPa)
- Powersupply
- Built-inlithiumbattery(3.6VDC/3.8Ah),externalremotedataacquisitionsystempowersupplyispossible
- Batterylife:≥10years(Industrialstandard:built-inbatterylife>5+1years)
- Workingcurrent:10~40μA
- Safetyrequirements
- Whenthepowersupplyisstoped,therecorddataofheat,cumulativeflowandcorrespondingtimebeforepoweroff.Canreformnormalmeteringafterpowerisrestored
- Themeteringcharacterswillnotbeaffectedwhenthemagneticinterferencestrengthisnotgreaterthan100KA/m
- TheenclosureprotectiongradeisIP54
- Accordingtorelevantnationalstandard,intheenvironmentconditionofdryheat,cooling,steadydamp-heat,cyclicdamp-heatandcryogenicstorage,whentheanalogparametersareinput,theheatmetercanworknormally.
- Accordingtorelevantnationalstandard,intheenvironmentconditionofline-voltagevariation,electricalfasttransient,electromagneticfield,electricsurge,powerfrequencymagneticfieldandelectrostaticdischarge,theheatmetercanworknormally.
Send product request
Other supplier products
| split mechanical heat energy meter | ZYsplitmechanicalheatmeteradoptsanumberofpatentedtechnologyuniquetoWeihaizhenyuintelligenceandtechnologyCo.,Ltdindomesticandinnovativelydesignsthef... | |
| split type mechanical heat energy meter | ZYsplitmechanicalheatmeteradoptsanumberofpatentedtechnologyuniquetoWeihaizhenyuintelligenceandtechnologyCo.,Ltdindomesticandinnovativelydesignsthef... | |
| ZY series split non-magnetic calorimeter | ZYseriessplitmechanicalheatmeterZY-DN20-50 ZYsplitmechanicalheatmeteradoptsanumberofpatentedtechnologyuniquetoWeihaizhenyuintelligenceandtechnology... | |
| no baffle-board ultrasonic calorimeter | “ZY-DN20,ZY-DN25noreflectionplateultrasonicheatmeter”techniquecharacters (1)Theflowsensorisnoreflectionstructureusingmeasurementpipei... | |
| ZY no baffle-board ultrasonic heat meter | Features: Splitinstallation Canbedismountedforcleaningandmaintenance Convenientforverifyingandcalibratingagainafterusage Goodinstallationadaptabil... |
Same products
| Battery Powder Compaction Density Evaluation System | Seller: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Application (1) Measurement of tapped de... | |
| Lingfeng (LF) Air-Cooled Integrated Refrigeration Chillers | Seller: Beijing Linggong Technology Co., Ltd. | TheLingfeng(LF)Air-Cooled IntegratedRefrigerationChillersis a professional refrigeration equipmen... | |
| Low Temperature Chiller | Seller: Beijing Linggong Technology Co., Ltd. | Low Temperature Chiller The conditioning deviceis specifically designed for thermal and fluid dy... | |
| Low-Temperature Control System | Seller: Beijing Linggong Technology Co., Ltd. | Low-Temperature Control System The conditioning deviceis specifically designed for thermal and f... | |
| Plastic Smoke Density Tester F313 | Seller: Standard International Group (HK) Limited | The F313 Plastic Smoke Density Tester is a precision instrument designed to measure the specific ... |