No baffle-board ultrasonic heat meter
- Structure
·Flowsensor:straightthroughtypeinwallreflectionultrasonicflowsensorwithnoreflectionplatestandandbeampieces
·Temperaturesensor:PT1000temperaturesensorpair
·Opticalinterface,M-businterfacefordatacommunication
- Flow
- Ratedflow:1.5~3.5m³/h
- Ratedflowandminflowproportionis100.
- Temperatureandtemperaturedifference
- Temperaturemeasurementrange:4~95℃
- Temperaturedifference:3~90℃
- Thermalcoefficient:Alongwithinletandoutletwater
- Connectionmode
- Installationposition:inletoroutletasinstructed(optional)
- Connectiontype:threadedconnection
- Maxworkingpressure:1.6MPa
- Servicecondition
- Environmentcondition:ClassA
- Display
- Display:LCD,8digits,specialsymbols
- Dimension:kWh,MJ
- Resolution
(1)Heat:1kWhor1MJ
(2)Cumulativeflow:0.01m³
(3)Temperature:0.1℃
(4)Temperaturedifference:0.1K
- Datastorage
- Datastorage:ROM
- Storeatleast18months’data
- Intensityandtightness
- Nodamageandleakagewhenthemediumtemperatureis10℃lessthanthemaxworkingtemperatureandthepressureis1.6timesgreaterthanthemaxworkingpressure.
- Accuracy
- MeteringaccuracyisClass2
- Pressureloss
- Pressureloss<10kPa(Industrialstandard:Maxallowedpressurelossis25kPa)
- Powersupply
- Built-inlithiumbattery(3.6VDC/3.8Ah),externalremotedataacquisitionsystempowersupplyispossible
- Batterylife:≥10years(Industrialstandard:built-inbatterylife>5+1years)
- Workingcurrent:10~40μA
- Safetyrequirements
- Whenthepowersupplyisstoped,therecorddataofheat,cumulativeflowandcorrespondingtimebeforepoweroff.Canreformnormalmeteringafterpowerisrestored
- Themeteringcharacterswillnotbeaffectedwhenthemagneticinterferencestrengthisnotgreaterthan100KA/m
- TheenclosureprotectiongradeisIP54
- Accordingtorelevantnationalstandard,intheenvironmentconditionofdryheat,cooling,steadydamp-heat,cyclicdamp-heatandcryogenicstorage,whentheanalogparametersareinput,theheatmetercanworknormally.
- Accordingtorelevantnationalstandard,intheenvironmentconditionofline-voltagevariation,electricalfasttransient,electromagneticfield,electricsurge,powerfrequencymagneticfieldandelectrostaticdischarge,theheatmetercanworknormally.
Send product request
Other supplier products
| detachable split mechanical energy meter | Features: Splitinstallation Canbedismountedforcleaningandmaintenance Convenientforverifyingandcalibratingagainafterusage Goodinstallationadaptabi... | |
| No baffle-board ultrasonic heat meter | Structure ·Flowsensor:straightthroughtypeinwallreflectionultrasonicflowsensorwithnoreflectionplatestandandbeampieces ·Temperaturese... | |
| ZY series split non-magnetic calorimeter | ZYseriessplitmechanicalheatmeterZY-DN20-50 ZYsplitmechanicalheatmeteradoptsanumberofpatentedtechnologyuniquetoWeihaizhenyuintelligenceandtechnology... | |
| Ultrasonic heat energy meter WITHOUT REFLECTION PLATE | Capability Parameter NominalDiameter(mm) DN15 DN20 DN25 DN32 DN40 Ratedflow(m³/h) 2.5 6 10 MinFlow(m³... | |
| Superconducting radiator | Superconductingheattransferisanenergy-savingadvancedtechnologywhichwasfirstlyinventedandappliedinmannedspaceflightbyAmericaaerospaceengineeringandt... |
Same products
| Optical Brightener OB-1 (OBA 393) | Seller: Jinan Ogilvy Chemical Co., Ltd | Chemical Name: 2-[(Ethylsulfanyl)methyl]phenyl methylcarbamateC.I.: 393CAS: 1533-45-5Molucular Fo... | |
| PH-A63 Waterproof PH/EC/Temperature Meter | Seller: Kelilong Electron Co.,Ltd | Model PH-A63 Range PH ~14.00PH EC 0~19.99mS/c... | |
| PH-A6 Waterproof pH and Temperature Meter | Seller: Kelilong Electron Co.,Ltd | Model PH-A6 Range PH ~14.00PH Temp 0~50℃ ... | |
| PH-A8 Waterproof Soil PH Meter | Seller: Kelilong Electron Co.,Ltd | Model PH-A8 Range PH ~14.00PH Temp 0~50℃ ... | |
| TH021WIFI Internet of Things TEMP&HUMIDITY Controller | Seller: Kelilong Electron Co.,Ltd | Product description: The electronic thermostat can be used for a variety oftemperature control... |