FDH-0501turbine oil containing antioxidant oxidation stability tester
Technical Specifications
Turbine oil containing antioxidant oxidation stability analyzer designed and manufactured in accordance with the requirements of SH/T0124, will be equipped with the oxidation of the sample tube into the Heating method temperature is 120 ° bath in oxygen 164H, Determination of Volatile acid end of the experiment soluble acid and clay content.
Function Features
1, turbine oil containing antioxidant oxidation stability tester with LCD display, Chinese operation interface
2, turbine oil containing antioxidant oxidation stability tester using SCM automatic control experiment without human duty
3, turbine oil containing antioxidant oxidation stability tester assay variation of various parameters
4, containing antioxidants turbine oil oxidation stability analysis with self-diagnostic function, suggesting operating functions
5, turbine oil containing antioxidant oxidation stability tester metal bath Heating method , safety and environmental protection
Technical parameters
1, Applied standards: SH/T0124
2, Temperature range: 80 ℃ ~ 150 ℃,Temperature control Precision: ± 0.5 ℃,
3, temperatureTemperature control means: PIDTemperature control
4, detection unit: 2 groups
5, power supply Power supply: 220V
Send product request
Other supplier products
Lubricant foam performance analyzer FDT-1102 | 24 ± 0.5 ℃ ~ 93.5 ± 0.5 ℃, penetration :3000 ~ 6000ml/min, with the refrigeration system, the implementation of standards: GB/T12579. | |
(Coulometry) sulfur content analyzer FDR-3105 | Application range Microcoulometric sulfur measurement instrument using the principle of micro-coulometric titration, after the sample combustion re... | |
Automatic trace moisture analyzer FDT-1371 | Automatic trace moisture analyzer FDT-1371 Application range The automatic trace moisture analyzer is the design and manufacture of the requireme... | |
Auto paraffin light stability analyzer FDS-1201 | Automatic the paraffin light stability analyzer FDS-1201 Application range Paraffin Light Stability Tester applicable standards: SH/T0404 The i... | |
FGC-1070 gas chromatograph | Index detector Sensitivity Drift Linear FID flame Mt<5 × 10-12g / s (n-hexadecane) <0.2mv / h > 106 TCD TCD... |
Same products
Walk In Environmental Chamber | Seller: Guangdong ALI Testing Equipment Co,.Ltd | Application JOEO Multi-functional walk in environmental chamber is the perfect testing place for ... | |
Solid Walk In Test Chamber | Seller: Guangdong ALI Testing Equipment Co,.Ltd | Application: JOEO solid walk in test chamber is an all-welded test chamber with an integrated con... | |
Compact Walk In Environmental Chamber | Seller: Guangdong ALI Testing Equipment Co,.Ltd | Application JOEO compact walk in environmental chamber is used to test full-size solar panels or ... | |
Drying Walk In Environmental Chamber | Seller: Guangdong ALI Testing Equipment Co,.Ltd | Application Dry walk in environmental chambers are a special type of walk in environmental chambe... | |
Walk In Test Chamber For CATL Battery | Seller: Guangdong ALI Testing Equipment Co,.Ltd | CATL Battery Walk In Test Chamber JOEO Walk In Test Chamber's temperature cyclic stress screening... |