Sulfur Dioxide and Hydrogen Sulfide Corrosion Test Chamber for Automotive Connectors
Meeting Standards:
Carry out various sulfur dioxide gas corrosion tests in accordance with GB10587 - 89, GB2423.9 - 93, GJB150, QC/T417.1 - 2001 and equivalent standards such as IEC, DIN, MIL, ASTM.
Technical Parameters:
1. Temperature range: 10 - 55°C 2. Temperature fluctuation: ±0.5°C 3. Temperature uniformity: ±2°C 4. Sulfur dioxide gas concentration: 100ppb - 50000ppb (0.1ppm - 50ppm) 5. Hydrogen sulfide gas concentration: 10ppb - 5000ppb (0.01ppm - 5ppm) 6. Relative humidity: 75±3% 7. Tests with sulfur dioxide, hydrogen sulfide, and mixed gases of sulfur dioxide and hydrogen sulfide can be conducted.
Environmental Requirements:
1. Power supply: AC380V 3Φ 10KVA 0HZ 2. Allowable voltage range: ±5% of the rated value 3. Maximum load: 6KVA 4. The distance between the chamber and the wall should be greater than 600cm.
Structural Materials and Features:
1. The chamber is molded from epoxy fiberglass. Asbestos board is pasted inside the jacket. It is resistant to high temperature and corrosion, lightweight, and has high strength. Both the inner and outer walls of the chamber are smooth and easy to clean. 2. The chamber cover is made of epoxy fiberglass with a top cover temperature of 100 - 200°C to prevent condensed water in the chamber from dripping directly onto the test specimens. 3. Heater: The nickel - chromium alloy heating wire heats from the bottom, forming jacket heating to ensure good temperature uniformity inside the chamber. 4. Humidification method: Humidification by a steam generator. 5. Input methods for sulfur dioxide and hydrogen sulfide: Input from cylinders, and both input and discharge are quantitatively controlled by concentration sensors. 6. Exhaust gas treatment: Install treatment devices for sulfur dioxide and hydrogen sulfide gases. After multi - stage treatment with sodium bicarbonate, the exhaust gas meets the discharge standards (the purification device is external).
Control System:
1. Temperature control: Japanese Fuji temperature controller 2. Temperature input: PT100; Output: Driven by SSR 3. Display range: 0 - 100°C 4. Control range: RT + 5 - 55°C 5. Cycle used (measurement filtering): 2 - 3s 6. The main control components are products from joint - venture companies. 7. The temperature is controlled by a solid - state relay, with stable performance and no noise. 8. A fan is used for stirring and circulation inside the chamber. 9. Display and control of sulfur dioxide concentration
Send product request
Other supplier products
| Residual Ethylene Oxide Gas Chromatograph | The ethylene oxide residual gas chromatograph is a professional analytical instrument for detecting the residual amount of ethylene oxide in medica... | |
| Medical Face Mask Synthetic Blood Penetration meter | Applicable Standards: GB 19083-2010 YY/T 0691-2008 YY 0469-2011 ISO 22609 ASTM F1862-07 Features: 1. Mask fixture is metal human head mold, ... | |
| Automatic freezing point pour point cold tester | Product Introduction: The automatic freezing point pouring point Freezing point tester is suitable for petroleum, biological, chemical and other f... | |
| Building Material Non-Combustibility Test Machine, ASTM E2652, En ISO 1182 | Introduction: This machine is designed and manfacture according to ISO 1182 .Furnace temperature can quickly reach temperature equilibrium into th... | |
| Drying Rate Tester | The drying rate tester is a professional device used to measure the drying rate of a substance. Application fields Textile industry: used to eva... |
Same products
| Optical Brightener OB-1 (OBA 393) | Seller: Jinan Ogilvy Chemical Co., Ltd | Chemical Name: 2-[(Ethylsulfanyl)methyl]phenyl methylcarbamateC.I.: 393CAS: 1533-45-5Molucular Fo... | |
| PH-A63 Waterproof PH/EC/Temperature Meter | Seller: Kelilong Electron Co.,Ltd | Model PH-A63 Range PH ~14.00PH EC 0~19.99mS/c... | |
| PH-A6 Waterproof pH and Temperature Meter | Seller: Kelilong Electron Co.,Ltd | Model PH-A6 Range PH ~14.00PH Temp 0~50℃ ... | |
| PH-A8 Waterproof Soil PH Meter | Seller: Kelilong Electron Co.,Ltd | Model PH-A8 Range PH ~14.00PH Temp 0~50℃ ... | |
| TH021WIFI Internet of Things TEMP&HUMIDITY Controller | Seller: Kelilong Electron Co.,Ltd | Product description: The electronic thermostat can be used for a variety oftemperature control... |