.

Yokogawa AXF Magnetic Flowmeter Integral Flowmeter Remote Flowtube

                                         Yokogawa AXF Magnetic Flowmeter  Integral Flowmeter Remote FlowtubeFeature:User-oriented FunctionalityFluid Adhesion Level Diagnosis :By constantly monitoring the level of insulatingsubstance on the electrodes,Website:, it is possible to determinewhen maintenance is required.With the utilization of an optional replaceable electrode,the electrodes can be easily removed from the flowmeterand cleaned.Flexible Electrical Connection DirectionThe converter or the terminal box can be rotatedarbitrarily to change the directions of electricalconnection on the site.Clear and Versatile IndicationsThe LCD indicator employs a large, backlit full dotmatrix, that can facilitate various displays.One to three lines are available. When there is an alarmcondition, a full description of the countermeasure isindicated.“Easy Setup” Parameters “”The most frequently used parameters are arranged in agroup at the top.The infra-red switches enable the users to setparameters without opening the cover.● Expansion of Product LineupImproved Accuracy SpecificationThe standard accuracy is 0.35% of reading. Alsoavailable is an optional high accuracy calibration rated at0.2% of reading. Specifications : *1: Select two points from: one pulse output, one alarmoutput, one status input, or two status outputs.*2: For models without an indicator, the configuration tool(Such as HHT (handheld terminal) or FieldMateTMetc.) is necessary to set parameters.Excitation Method:• Standard dual frequency excitation:Size 2.5 to 400 mm (0.1 to 16 in.)• Enhanced dual frequency excitation:Size 25 to 200 mm (1.0 to 8.0 in.)(Optional code HF1 or HF2)Input Signal (*1) “”:One Status Input: Dry contactLoad Resistance: 200 Ω or less (ON), 100 kΩ or more(OFF)Output Signals “”:• One Current Output: 4 to 20 mA DC (load resistance:750Ω maximum, including cable resistance)• One Pulse Output (*1):Transistor contact output (open collector)Contact capacity: 30 V DC (OFF), 200 mA (ON)Output rate: 0.0001 to 10,000 pps (pulse/second)• One Alarm Output (*1):Transistor contact output (open collector)Contact capacity: 30 V DC (OFF), 200 mA (ON)• Two Status Outputs (*1):Transistor contact output (open collector)Contact capacity: 30 V DC (OFF), 200 mA (ON)Communication Signals “”:BRAIN or HART communication signal(Superimposed on the 4 to 20 mA DC signal)Distance from Power Line: 15 cm (6 in.) or more(Parallel wiring should be avoided.)BRAIN:Communication Distance:Up to 1.5 km (0.93 miles), when polyethylene insulatedPVC-sheathed cables (CEV cables) are used.Communication distance varies depending on the typeof cable and wiring used.Load Resistance:250 to 450Ω (including cable resistance)Load Capacitance: 0.22 µF or lessLoad Inductance: 3.3 mH or lessInput Impedance of Communicating Device:10 kΩ or more (at 2.4 kHz)HART:Load Resistance:250 to 600Ω (including cable resistance)Note: HART is a registered trademark of the HARTCommunication Foundation.Data Security During Power Failure:Data (parameters, totalizer value, etc.) storage byEEPROM. No back-up battery required Technical parameters :  Products show :  Why chose us : 


Send product request

To: Xi’an Xinyuan Industrial Equipment Co.,Ltd
Your E-mail:
Message text:


Send to other suppliers

Other supplier products

YTA310 Temperature Transmitter
YTA310 Temperature Transmitter                                             YTA310 Temperature TransmitterFeature :The YTA310 and YTA320 are the highly accurate temperature transm...
Rosemount R-Series Mass And Volume Flowmeter
Rosemount R-Series Mass And Volume Flowmeter                    R-Series Mass and Volume FlowmeterFeature :The R-Series flowmeters are competitive in both price and accuracy specifications wit...
J6 UE Pressure And Vacuum Switches
J6 UE Pressure And Vacuum Switches                                  J6 UE Pressure and Vacuum switchesOverview :.The J6 is a reliable,Website:, sensitive pressure switch, originally ...
Rosemount™ 8800D Series Vortex Flowmeter
Rosemount™ 8800D Series Vortex Flowmeter                      Rosemount™ 8800D Series Vortex Flowmeter Feature :HART® and FOUNDATION™ Fieldbus ProtocolsAll welded,Website:, non-clog design...
117 Series UE Pressure Switch
117 Series UE Pressure Switch                                             117 Series UE Pressure SwitchOverview : Approved for Division 2,Website:, Zone 2 hazardous and corrosiv...
All supplier products

Same products

Wall Mounted Ultrasonic Flow Meter
Wall Mounted Ultrasonic Flow Meter Seller: ACE METER TECHNOLOGY CO.,LIMITED The Wall Mounted Ultrasonic Flow Meter is the basic type of ultrasonic flow meter. It is combined...
Vortex Steam Flow Meter
Vortex Steam Flow Meter Seller: ACE METER TECHNOLOGY CO.,LIMITED The Steam Mass Vortex Steam Flow Meter are designed for accurate, cost effective mass flow measur...
Coriolis Oil Mass Flow Meter
Coriolis Oil Mass Flow Meter Seller: ACE METER TECHNOLOGY CO.,LIMITED The Durable Coriolis Fuel Mass Flow Meter for Marine Oil is a good choice for fuel measuring, wil...
Digital Liquid Turbine Flow Meter
Digital Liquid Turbine Flow Meter Seller: ACE METER TECHNOLOGY CO.,LIMITED The liquid turbine diesel flow meter is a flow meter which specially for diesel measuring.the flo...
Natural Gas Turbine Flow Meter
Natural Gas Turbine Flow Meter Seller: ACE METER TECHNOLOGY CO.,LIMITED Natural Gas Turbine flow meter measure the velocity of natural gas in pipes, such as High accurac...