JCMC Multivariable Transmitter with hart

JCMC Multivariable Transmitter with hart

consists of a differential pressure sensor module with integrated electronic adapter unit, an amplifier module with a control unit and a two-wire system RTD input terminal to measure process temperature

The transmitter adopts modularized design. It consists of a differential pressure sensor module with integrated electronic adapter unit, an amplifier module with a control unit and a two-wire system RTD input terminal to measure process temperature. The sensor module adopts full-welded structure, interior of whichis a twin-barrel system with an intact overload isolation diaphragm, and one absolute pressure sensor and one differential pressure sensor are installed inside. The absolute pressure sensor is only installed on the high-pressure side, and the measured pressure will be taken as reference value, in order to compensate influence from static pressure. The differential pressure sensor is made up of one capillary tube connected with negative pole of the sensor module.

An additional differential pressure (Dp) will be applied onto diaphragm of the differential pressure sensor through the isolation diaphragm and filler liquid. Check for tiny variation of the diaphragm, which shall result in changes of output voltage of the testing system. The voltage signal direct proportional to the input pressure will be digitalized through the adapter before being transmitted into the amplifier, and then the amplifier will perform linearization on the signal as well as temperature compensation. Then, three values of Dp, P and T can be converted signals direct proportionalto mass flowrate through compensation. Except for mass flowrate (Qm), Dp, P, T and Qv can also make for other purpose of application. According to differences of transmitter models, connection betweenthetransmitter and process can be fulfilled through female screw on elliptic flange on the transmitter, or connection between remote flanges and process pipelines or flanges.

The transmitter adopts a two-wire system, the same pair of leads in which can be used to connect working voltage, signal outputs (4~20mA) and digital quantities. Electrical connection can be fulfilled throughinterconnection with terminals through cable inlet.

Model Selection

Sample

JCMT

JCMT Multivariable Pressure Transmitter

Output

H

Two wire 4-20ma DC ( Hart )

M

M

Three wire 4-20ma DC Output: flow rate

Sensor

Differential Pressure

Compound Micro-Silicon Sensor

Capacitance Sensor

B

A

0-50pa to 1pa (Rated pressure is 0.6mpa)

2E

0 to 1.5Kpa

B

0 – 200pa to 6 kpa

3E

0 to 7.5kpa

C

0 -400pa to 40kpa

4E

0 to 37.4 kpa

D

0-2.5kpa to 250 kpa

5E

0 to 186 kpa

PERFORMANCE SPECIFICATIONS

Reference Accuracy of Calibrated Span (includes

terminal-based linearity, hysteresis, and repeatability)

± 0.1%/± 0.01%

If TD>10 (TD=URL/SPAN):

±(0.0075×TD)%/ ±(0.01×TD)%

Ambient Temperature Effects

-20℃~65℃:±(0.15×TD+0.05)%×Span

Every 10℃ is ±0.08% ×Span (TD=1)

-40℃~-20℃ & 65℃~85℃:

±(0.2×TD+0.05)%×Span

Static Pressure Effects

±(0.05%URL+0.075%Span)/10MPa

Overpressure Effects: ±0.1%×Span /10MPa。

Stability: ±0.1%×Span /3 years

Power Supply Effects

±0.001% /10V (12~42V DC)

Measuring Temperature

-50℃~650℃

Zero Adjustment Limits

Zero can be fully elevated or suppressed, within the

lower and upper range limits of the capsule.

External Zero Adjustment

External zero is continuously adjustable with 0.01%

incremental resolution of span. Re-range can be done

locally using the range setting switch.


Send product request

To: Jiangsu BCST Group Co.,Ltd.
Your E-mail:
Message text:


Send to other suppliers

Other supplier products

Top Guide Single Seat Control Valve KTSP
Top Guide Single Seat Control Valve KTSP Top Guide Single Seat Control Valve KTSP KTSP Top Guide Single Seat Control Valveis a kind of control vlave with top guide structure, guide area b...
JC010 Thermal Mass Gas Flow Meter
JC010 Thermal Mass Gas Flow Meter JC010 Thermal Mass Gas Flow Meter The principle is that a fluid flowing past a heated temperature sensor removes a known quantity of heat as it pa...
JCLC Oval Gear Flowmeter with Pulse
JCLC Oval Gear Flowmeter with Pulse JCLC with Pulse Ovalgearmeters are instruments used for the continuous and intermittent measurement and control of the pipe liquid flow, which are ...
JC040 Vortex Natural Gas Flow Meter
JC040 Vortex Natural Gas Flow Meter JC-040 series smart precession whirlpool flowmeter uses new microprocessing techn ology with strong function, wide flow range, simple maintenance a...
JCBP Inline Gauge pressure transmitter
JCBP Inline Gauge pressure transmitter JCBP Inline Gauge pressure transmitter BCST, JCBP/JCBA inline pressure transmitter series is a digital pressure transmitter designed for industrial...
All supplier products

Same products

Temperature Transmitter
Temperature Transmitter Seller: Beijing Gallop High& New Tech Co.,Ltd Temperature transmitteradopts thermonuclear, RTD as temperature measuring element, the output sig...
Capsule Type Pressure Transmitter
Capsule Type Pressure Transmitter Seller: Beijing Gallop High& New Tech Co.,Ltd To convert measured pressure values into standard industrial signals, such as 4-20mA, 0-20mA, 0-5...
Allen-Bradley PLC Module 1769-IA16
Allen-Bradley PLC Module 1769-IA16 Seller: 840499 Allen-Bradley PLC Module 1769-IA16 The Bulletin 1769 Compact I/O™ chassis-based modules ca...
Temperature & Humidity Transmitter
Temperature & Humidity Transmitter Seller: Tinko Instrument (Suzhou) Co., Ltd. Tinko high temperature humidity transmitterare suitable for HAVC temperature and humidity measure...
TKSD Duct Mounted Transmitter
TKSD Duct Mounted Transmitter Seller: Tinko Instrument (Suzhou) Co., Ltd. TKSD series temperature transmitter with displayare designed for indoor air temperature and humid...