High Speed 3d & 2.5d Scanning System 14mm
The 2.5D&3D system has the function of conventional 2D galvanometer, and a zoom module is added on the basis of the conventional galvanometer, which solves the problem that the traditional laser scanning galvanometer can only realize plane scanning and small range scanning, and can complete laser processing system applications requiring dynamic zoom. Mainly used in glass drilling, 3D curved marking, welding, laser digging groove, step surface marking and so on. At the same time, this galvo head has the characteristics of high precision, high stability and support for function customization.
Key Features Of High Speed 3d & 2.5d Scanning System 14mm
Using 14mm 2D galvanometer and VCM-Z reflection z-axis focusing system, X, Y, Z-axis dynamic response perfectly matching, realizing high-speed 3D processing
UV, green and infrared three bands available
High speed glass drilling applications with front focusing field mirror
Optional 14mm UltraScan and Extrascan galvanometers are available according to customer's different accuracy and speed requirements
Specifications Of High Speed 3d & 2.5d Scanning System 14mm
ltem |
Unit |
Parameter |
||||||||
Power Supply |
Input Voltage |
vac |
170-264 |
|||||||
Output Voltage |
vdc |
±15 |
||||||||
Current |
a |
10 |
||||||||
Control Card |
Input Interface |
XY2-100 |
||||||||
Output Interface |
Entermet Port |
|||||||||
Laser Type |
Ultraviolet、IR、Green |
|||||||||
EnvironmentalRequirement |
Ambient Temperature |
℃ |
0~+40 |
|||||||
Storage Temperature |
℃ |
一10~+60 |
||||||||
Humidity |
≤75% Non-Condensing |
|||||||||
SpecificationsForDefiectionUnit |
Scan angle |
° |
±11.5 |
|||||||
Repeatability |
urad |
5 |
||||||||
ppm/K |
12 |
|||||||||
urad/K |
30 |
|||||||||
Long-Term Driff Over 8h |
mrad |
|||||||||
Maximal Processing Speed |
s |
650 |
||||||||
Small Step Response |
ms |
≤0.18 |
||||||||
Dynamic zoom system parameters |
Small Step Response |
ms |
≤1.6 |
|||||||
SpecificationsForOptics |
Laser |
UV Laser |
YAG/Fiber |
Green |
||||||
Wavelenth |
nm |
355 |
1064 |
532 |
||||||
Coating |
Anti-Reflection Film |
|||||||||
Aperture Size |
mm |
φ14 |
||||||||
System Input Laser Beam |
mm |
9 |
7 |
|||||||
SpecificationsFor Structure |
Weight |
Kg |
8 |
|||||||
Dimension(L×W×H) |
mm |
|||||||||
3D systemField Size&Spot Diameter |
Ultraviolet |
Field Size |
mm |
100x100x40 |
200x200x80 |
300x300x150 |
400x400x150 |
500x500x150 |
600x600x150 |
|
The Smallest Spot diameter1/e² |
mm |
|||||||||
IR |
Field Size |
mm |
60x60x60 |
100x100x90 |
100x100x40 |
200x200x80 |
||||
The Smallest Spot Diameter1/e² |
mm |
|||||||||
Green |
Field Size |
mm |
100x100x40 |
200x200x80 |
300x300x150 |
400x400x150 |
500x500x150 |
600x600x150 |
||
The Smallest Spot diameter1/e² |
mm |
|
||||||||
Green 2.5D System |
Wavelength |
nm |
532nm |
|||||||
Aperture Size |
mm |
φ14 |
||||||||
System Input Laser Beam |
mm |
φ3.5 |
||||||||
Field Size |
mm |
70x70 |
||||||||
Focus Range In Z-Direction |
mm |
±5mm |
||||||||
Distance Of F-Theta From Working Face |
mm |
|||||||||
The Smallest Spot diameter1/e² |
mm |
|||||||||
Application Industry |
Glass Panel Cutting&Driling |
|||||||||
Machining Efficiency |
3mm Thick Glass,with Aperture Of 4.6mm, Cutting Time≤15s |
|||||||||
IR 2.5D System |
Wavelength |
nm |
1064nm |
|||||||
Aperture Size |
φ14 |
|||||||||
System Input Laser Beam |
7mm |
|||||||||
Field Size |
mm |
210*210 |
||||||||
Focus Range In Z-Direction |
mm |
±20mm |
||||||||
Distance Of F-Theta From Working Face |
mm |
330mm |
||||||||
The Smallest Spot Diameter1/e² |
um |
45 |
Hansscannerprovides galvo head, galvanometer scanner, laser galvoand etc. If you want to know more, pleasecontact us.
Отправить запрос, связаться с поставщиком
Другие товары поставщика
2-axis Galvo Scan Head | Excellent driver board and 2 axis mirror galvanometermatching to achieve superior speed performance, reduce the first stroke of a character and cor... | |
3-axis Galvo Scan Head | 3-axis Galvo Scan Head The large-format 3D laser scanner headis free of the processing range limits of 2D field lenses, and can be flexibly select... | |
Scanning Solutions | Our scanner systems can process non-metallic and partial metallic materials. It is widely used in many industries, such as food packaging, beverage... | |
VCM Z | The traditional Z-axis focusing module adopts voice coil motor or galvanometer structure, which has high load quality, slow response time and low d... | |
High Speed 3d & 2.5d Scanning System 14mm | The 2.5D&3D system has the function of conventional 2D galvanometer, and a zoom module is added on the basis of the conventional galvanometer, ... |
Похожие товары
Floral Garden Tools Set | Продавец: Dongyang Guorui Industry And Trade Co., Ltd. | Investing in a floral garden tools set not only enhances your gardening experience but also add... | |
Rice Husk Pellet Machine | Продавец: Jiangsu Kingwood Industrial Co., Ltd. | ● JWZL-420 is the most popular biomass/woodpellet machine of all the pellet mills offered by Ch... | |
Греция-Генетические криобанки-Криоконсервация клеток | Продавец: Хэнань Тяньчжидао Биотехнология Лтд. | В наше время, когда технологии не перестают развиваться, с увеличением требований к криохранению ... | |
Common Rail Fuel Injector Nozzle L500PBC | Продавец: 738347 | Common Rail Fuel Injector Nozzle L500PBC 0 445 110 189 Injector Valve Set 0 445 110 190 Injector... | |
Common Rail Fuel Injector Nozzle F00VX40014 | Продавец: 738347 | Common Rail Fuel Injector Nozzle F00VX40014 Common Rail Fuel Injector Nozzle F340 Common Rail ... |