LBS 24KV 630a SF6 Gas Load Break Switch
24kV SF6 load break switch is a switch equipment for medium voltage switchgear, using SF6 gas as arc extinguishing and insulating medium. Rate voltage was 24kV, rate current was630A
LBS 24KV 630aSF6 Gas Load Break Switch Application
The SF6 LBS 24kv 630A gas-insulated switch is a three-phase interoperable switching device designed for use in distribution system cabling and overhead power line segment applications.
The 24KV pole mounted disconnect switch can be operated manually in the field or remotely from the control center.
LBS 24KV 630a SF6 Gas Load Break Switch Technical Parameters
|
Products Type |
FWX-24 |
|
Basic Ratings |
|
|
Maximum System Voltage |
24kV |
|
Rated Continuous Current |
630A |
|
Rated Frequency |
50/60Hz |
|
Short Time Withstand Current |
16kA/1sec |
|
Making and Breaking Capacity |
|
|
Mainly Active Load Current |
630A |
|
Number of Load-break Operations |
400times |
|
Short-circuit Making Current (peak) |
40kA |
|
Number of Making Operations |
5 times |
|
Cable Charging Current |
25A |
|
Line Charging Current |
|
|
Closed Loop Circuit Current |
630A |
|
Transformer Magnetizing Current |
22A |
|
Power Frequency Withstand Current Test |
|
|
Wet Condition-10sec Ph- Ph-Eth, Across Interrupters |
50kV |
|
DryCondition-1min,Ph- Ph, Phase to Earth |
64kV |
|
Dry Condition - 1 min Across Interrupter |
79kV |
|
Impulse Withstand Current Test( 1.2 x 50 µs ) |
|
|
Phase to Phase, Phase to Earth |
125kV |
|
Across Interrupter |
145kV |
|
Other Ratings & Specifications |
|
|
Internal Arc Test |
20kA /0.1 sec |
|
Arc Extinction Medium |
SF6 Gas |
|
Insulation Medium |
SF6 Gas |
|
Creepage Distance (Porcelain) |
700mm |
|
Creepage Distance (Silicon) |
1200mm |
|
Dry arcing distance |
≥ |
|
IP Level |
65 |
|
Operation Performance |
|
|
Closing/Opening Time |
<1sec |
|
Mechanical Operations (Guaranteed) |
10000times |
|
Operating Temperature (*Manual Type) |
-25~+70℃ |
|
Gas Pressure |
|
|
Nominal Pressure (MPa, at 20°C) |
|
|
Bursting Pressure (MPa) |
|
|
Minimum Gas Pressure (MPa) |
|
|
Leakage Rate (cc/ sec) |
≤0.5% |
|
Voltage sensors |
|
|
CT ABC 10P10 5VA |
400:05:00 |
|
Incoming side and outgoing side of the voltage sensor |
6 Voltage sensor(built-in) Phase voltage:(24(36)kV/√3)/(3.25V/√3) |
|
Special attention should be paid to the voltage sensor, which must be directly fed by theLBS load break switch. No additional adjustment circuit can be added to the controller. The voltage signal of the switch into the test line needs to be tested separately. |
|
Gopoweris a professional electric power equipment company, we provide auto recloser, electrical control box, recloserand etc. For 33kv auto recloser priceor more information, please feel free to contact us!
Отправить запрос, связаться с поставщиком
Другие товары поставщика
| 15KV SF6 Gas Load Break Switch | 15 kv pole mounted disconnect switch is suitable for rated voltage 15kV, rated current 630A, 50/60Hz distribution network breaking. The load curren... | |
| 11KV Auto Recloser Vacuum Circuit Breaker | 11KV Auto Recloser Vacuum Circuit Breaker ZW32 series 11 kv outdoor vcbvacuum circuit breakers are used in distribution systems and pole mounted r... | |
| 33KV SF6 Gas Load Break Switch | These load break switch 33kvare intended for outdoor applications. They can be mounted either horizontally or vertically, and are suitable for elec... | |
| 24KV SF6 Gas Load Break Switch | Application of 24KV SF6 Gas Load Breaker Switch The SF6 lbs 24kv 630agas-insulated switch is a three-phase interoperable switching device design... | |
| SF6 Gas 11 KV Load Break Switch | The load break switch 11kvis suitable for the distribution network with the highest voltage 11kV, the rated current 630A, and the rated frequency 5... |