Centralized Type DTU
The centralized DTU adopts high-performance MCU processor, high-speed industrial network communication technology, multi-CPU integration technology and Linux operating system. The product has strong stability, high reliability, good real-time performance, and strong environmental adaptability. Mainly used in the ring network cabinets, switching stations, box-type substations, etc. in the distribution network, combined with the main distribution station, it can quickly and reliably realize the fault location and isolation of the electrical distribution cabinet and the restoration of the power supply in the non-faulty section. It is a kind of new generation of scada remote master terminal units for distribution automation that integrates telemetry, remote control, protection and communication functions.
Description and Functions of Centralized Type DTU
With "communication", it has "remote maintenance" function.
Flexible configuration, all protection functions have separate retreat.
The device has a complete self-checking function to detect the working conditions of each part online.
The closing and closing circuit adopts anti-misoperation design and has anti-missing function.
Applicable to analog acquisition, state quantity acquisition, local and remote control switch closing of 4-12 switch
24 channels can be controlled by expansion
By selecting different configurations, it can meet the needs of “Three Remote” and “Two Remote” of State Grid and South Grid.
Meet the special requirements of all parts of the country (such as Shandong, Beijing, Guangdong, etc.)
Zero-sequence current setting adaptive function, no manual setting required
Meet the specific requirements of “one or two integration”
The core unit can be flexibly configured to shade vertical, shaded horizontal, outdoor vertical and group screen.
Technical Parameters of Centralized Type DTU
Ac sampling |
Electromagnetic transformer |
Measuring voltage range |
0~200V(Un=100V) |
ratio (10KV/)/(0.1KV/) |
|||
Measuring zero-sequence voltage range |
0~200V(Un=100V/3) |
||
ratio (10KV/)/(0.1KV/) |
|||
Measuring current range |
|
||
Precision grade of measuring voltage and current |
Class 0.5 |
||
Protective current range |
0~100A( In=5A)/0~20A( In=1A) |
||
Protective current accuracy |
±3% |
||
Active power precision class |
Class 0.5 |
||
Reactive power accuracy class |
Class 1 |
||
Power factor resolution |
|||
Frequency measurement range |
45~55Hz |
||
Frequency measurement error |
<0.01Hz |
||
Electronic transformer |
Measuring voltage range |
0~6.5V(Un=3.25V/V) |
|
ratio (10KV/)/(3.25V/) |
|||
Measuring zero-sequence voltage range |
0~13V(Un=6.5V/3V) |
||
ratio (10KV/)/(6.5V/3V) |
|||
Measuring current range |
0~20V(In=1V) ratio 600A/1V |
||
Measuring zero sequence current range |
0~2V(In=0.2V) ratio 20A/0.2V |
||
Precision class of measuring voltage and current |
Class 0.5 |
||
Protective current range |
0~20V(In=1V) ratio 600A/1V |
||
Protective current accuracy |
±3% |
||
Zero sequence voltage / zero sequence current accuracy level |
Class 0.5 |
||
Active power precision class |
Class 0.5 |
||
Reactive power accuracy class |
Class 1 |
||
Power factor resolution |
|||
Frequency measurement range |
45~55Hz |
||
Frequency measurement error |
<0.01Hz |
If you are looking for a reliable electric power equipment company, please choose us, and we will be your best partner.
Отправить запрос, связаться с поставщиком
Другие товары поставщика
Centralized Type DTU | The centralized DTU adopts high-performance MCU processor, high-speed industrial network communication technology, multi-CPU integration technology... | |
Pole Mounted Switch | The pole mounted disconnect switchis a kind of safety switch used on the electric pole to ensure the safety of electricity. Its main function is to... | |
LBS 24KV 630a SF6 Gas Load Break Switch | 24kV SF6 load break switch is a sf6 load break switch for medium voltage switchgear, using SF6 gas as arc extinguishing and insulating medium. Rate... | |
11KV Vacuum Circuit Breaker | ZW32 series Breakers are used in distribution systems. Circuit breakers are used to make and break normal and fault currents. Breakers are fully eq... | |
Centralized Type DTU | Centralized Type DTU The centralized DTU adopts high-performance MCU processor, high-speed industrial network communication technology, multi-CPU ... |