HM-100 High-temperature Hygronom
Overview
Hygronom is also called moisture meter or dew-point meter, which is used to measure the humidity of flue gas emitted by pollution source. According to measured humidity, it converts wet gas concentration into dry gas concentration. In addition, it also can be used in industrial online humidity monitoring.
HM-100 gas moisture meteris equipped with an internal high-precision capacitance digital temperature & humidity sensor. The installation method adopts the in-situ immersion installation. It is a self-developed product, of which, the core component is from Switzerland. Put the sensor inside stack to get in touch with flue gas. The probe needs preheating to prevent gas from condensation, which will affect the measurement of moisture in the flue gas. After gas contacts with the measurement chip, the chip will change capacitance to measure flue gas concentration.
Features Of HM-100 High-temperature Hygronom
• The product is convenient for installation, disassembly, and cleaning with small and compact structure
• Direct and simple key operation on site
• The probe is equipped with heat tracing function to prevent condensate water from damaging humicap and thermal resistance
• Imported core components with high-performance index and reliability
Technical Parameter Of HM-100 High-temperature Hygronom
|
Measurement Range |
H2O: 0~40.00%(volume percent)(optional) |
|
Humidity sensor |
Resistance-capacitance |
|
Temp sensor |
Pt100 platinum resistor |
|
Accuracy |
0 ~ 40.00% H2O: ± 2% |
|
Repeatability |
0 ~ 40.00% H2O: ± 1% |
|
Stability |
0 ~ 40.00% H2O: ± 1% FS / 7d |
|
Response time |
T90 < 6s |
|
Sensor life |
>2 years (under normal use) |
|
Transmitter life |
>5 years (under normal use) |
|
Power supply |
220VAC |
|
Instrument weight |
About 10kg |
|
Power consumption |
Maximum about 35VA (heating) |
|
Ambient temperature |
Transmitter: -10°C~+55°C |
|
Probe: 0~180°C (except probe cable) |
|
|
Ambient humidity |
<95%RH |
|
Sample gas flow |
(2 ~ 6) L / min |
|
Analog output (2 sets) |
Temperature and humidity, 4-20mA |
|
Communication |
Rs232 (standard) |
Typical Application Of HM-100 High-temperature Hygronom
Отправить запрос, связаться с поставщиком
Другие товары поставщика
| Overview Of EM-5 Continuous Flue Gas Analyzer | HANGZHOU CHUNLAI (ZETIAN) TECHNOLOGY was established in 2008, and has national wide impact in China now as a fast-growing company specialized in en... | |
| Continuous Emission Monitoring System | Among all the continuous emission monitoring system suppliers, Zetian technology is the only high and new technology company with a full set of in... | |
| Vehicle Exhaust Remote Sensing System | Vehicle exhaust remote sensing system receives more attention and reliability with its advantages of speediness, convenience and wide monitoring ra... | |
| WDet-5000 Total Phosphorus Online Automatic Analyzer | Overview WDet-5000 is a self-developed total phosphorus on-line monitoring instrument. This product is based on the global initiative magnetic cond... | |
| WDet-7000 Integration Water Quality Online Analyzer | Overview WDet-7000 multi parameter water analyzerreal time water quality monitoring equipmentis a high-level integration of a multi-parameter water... |