Auto Relays
Auto off relay control higher voltages or currents by using lower voltages or currents. When a certain voltage or current is applied to both ends of the electromagnetic relay coil, the magnetic flux generated by the coil passes through the magnetic circuit composed of the iron core, the yoke, the armature and the working air gap of the magnetic circuit. Under the action of the magnetic field, the armature is attracted to the pole face of the iron core. Therefore, the normally closed contact of the contact is pushed to be disconnected, and the normally open contact is closed. When the voltage or current at both ends of the coil is less than a certain value, and the mechanical reaction force is greater than the electromagnetic attraction force, the armature will return to the initial state, the normally open contact is disconnected and normally closed contact is on.
Key Features of Auto Relays
With charatstic of high switching load power, high shock and vibration resistance.
Power 12V.
Power consumption 1.6~2W.
Ambient temperature -40℃~125℃.
How To Test Auto Relays?
(1) A simple method for judging the working performance of the auto relays.
Turn on the ignition auto relay switch, and then use your ear or stethoscope to listen to the sound of the control relay, or feel the vibration of the relay with your hand. If there is vibration, then the auto relays is working well, the electrical appliance does not work due to other reasons. Otherwise, the relay is not working properly.
You can also unplug the auto recloser relayfor testing, for example, if the air conditioner compressor does not work, you can start the engine, turn on the blower switch and the air conditioner switch. Then unplug the connector of the air conditioner compressor relay to judge. If the sound of the relay action can be heard, the engine speed drops significantly when the relay is unplugged, and the engine speed rises when the auto relays is inserted, it means that the air conditioner compressor relay and its control circuit are normal.
(2) Common failures of relays.
Common failure phenomena of relays include coil burnout, inter-turn short circuit or insulation aging, contact ablation, thermal decay, and inability to adjust the initial operating current.
①The relay coil is burnt out. In order to prevent this from happening, if the temperature may exceed 80°C during repair, maintenance and electric welding, the temperature-sensitive relays and electronic control units should be removed.
② Contact ablation. For example, vehicle with 491Q-ME engine, the relay of the air conditioner condenser fan is just below the glass cleaning spray pipe. If the spray pipe is broken, the cleaning fluid will leak to the relay, making the relay normally open contact is corroded and cannot be disconnected, which will lead to the failure of the air conditioner condenser fan to keep running. Therefore, water should be strictly prevented from entering the relay.
(3) Try to reduce the contact resistance of the relay contact.
The contact resistance existing between the contacts of the automotive relay is mainly composed of shrinkage resistance and surface film resistance. The contact resistance of the contact is related to the contact form, material properties and surface processing of the contact. It can be seen that to reduce the contact resistance of the relay contacts, under the condition of a certain contact pressure, it can be started by improving the contact state and improving the contact material.
(4) Poor grounding of the ECU may affect the normal operation of the relay.
Now the price of auto spares saleis reasonable, if you have needs, please contact us.
Отправить запрос, связаться с поставщиком
Другие товары поставщика
Turn Signal Switches | The clockwise lever of the turn aftermarket signal light switchturns right, the counterclockwise lever turns left, pushes the lever outwards for hi... | |
Fuel Filters | For vehicle engines, the Fuel Filterincludes Diesel Filter and Fuel Filter Diesel Filter elements mostly use filter paper, and some use felt or ... | |
Oil Filled Ignition Coils | The oil-filled ignition coil is the first generation coil of the vehicle. It is an open magnetic circuit ignition coil from MAMPS ignition coil fac... | |
Windshield Wiper System | The custom windshield wiper systemis not only as simple as wiping the water off the windshield, but also wipes the rainwater on the glass surface i... | |
Dimmer Switches | The car headlight switchare basically integrated on the lever switch on the left side of the steering wheel, but also there are exceptions. The hea... |
Похожие товары
Инжектор 320-0690 дизельного топлива Perkins высокой эффективности 2645A749 для двигателя Caterpillar C6.6 | Продавец: DIP (ДИЗЕЛЬНЫЕ ДЕТАЛИ) УСТАНОВКИ | ||
Инжектор 320-0677 дизельного топлива Perkins высокой эффективности 2645A746 для двигателя Caterpillar C6.6 | Продавец: DIP (ДИЗЕЛЬНЫЕ ДЕТАЛИ) УСТАНОВКИ | ||
Горячая продажа 7W7026 Форсунка дизельного топлива 7W-7026 Карандашная насадка для двигателя Caterpillar 3406 | Продавец: DIP (ДИЗЕЛЬНЫЕ ДЕТАЛИ) УСТАНОВКИ | Whatsapp/ со мной Pencil Nozzle 8N7005 Pencil Nozzle 4W7015 Pencil Nozzle 4W7... | |
Горячая продажа 7W7031 Форсунка дизельного топлива 7W-7031 Карандашная насадка для двигателя Caterpillar 3406 | Продавец: DIP (ДИЗЕЛЬНЫЕ ДЕТАЛИ) УСТАНОВКИ | Whatsapp/ со мной Pencil Nozzle 8N7005 Pencil Nozzle 4W7015 Pencil Nozzle 4W7... | |
How to Create an Efficient Warehouse Returns Process? | Продавец: HAI ROBOTICS | Hai Robotics is committed to helping customers achieve an efficient return process in warehouse. ... |