.

Commercial Water Source Heat Pumps For Cooling And Heating

Commercial water source heat pumps for cooling and heating This is water source heat pumps commercial use for cooling and heating,Website:, it is usually installed in area where weather very cold in winter, and in summer it can also supply chilled water for cooling.We only use the best quality and famous brand parts for assembling and all the testing for the heat pump parts and heat pump units will be finished by expert workers and engineers with professional equipment.Product Info.CompressorCopeland scroll or Panasonic scrollCapacity11KW,17KW,24KW,34KW,48KW,68KW,80KW,      120KW,160KWRefrigerantR410ACondenser"ND" shell and tube heat exchangerEvaporatorShell & tube, tube in tube or plate type heat exchangerAC contactor & RelaySchneiderElectronic expansion valveJapan Saginomiya or World No.1 SanhuaControllerLCDPackageWooden case or CartonFastenersStainless steel 304Additional Info. Delivery time25 days after order confirmedWarranty time24 months after shipmentPayment termT/T or L/C at sightProduction capacity400 units per monthBrandMES or OEMParameters Cooler-CW (Commercial Water source heat pump for cooling & heating) CL-CW-1609CL11s-CW5CL17s-CW5CL11-CW5CL17-CW5CL24-CW5CL34-CW10CL48-CW10CL68-CW20CL80-CW20CL120-CW20CL160-CW20Underground water open loopRated cooling capacityKWRated input power for coolingKW2.153.342.113.24.726.539.1813.1815.7223.3531.56Rated input current for coolingA9.5514.843.986.048.9112.3317.3524.9129.7144.1259.64Cooling performance coefficient (EER)/5.125.095.225.325.095.215.235.165.095.145.07Rated heating capacityKW9.5169.Rated input power for heatingKW2.594.382.594.316.098.8612.3318.0121.0132.3941.78Rated input current for heatingA12.3320.874.898.1511.5216.7523.334.0339.7161.2378.97Heating performance coefficient (COP)/3.673.653.673.713.613.613.653.613.573.553.59Application side heat exchanger water flowM3/h1.892.921.892.924.135.858.2611.713.7620.6427.52Heat source side heat exchanger water flowM3/h1.031.591.031.592.253.194.56.387.5111.2615.01Ground source closed loopRated cooling capacityKWRated input power for coolingKW1.963.171.953.134.386.178.8312.4814.922.2729.64Rated input current for coolingA8.714.113.685.918.2811.6516.6923.5828.1642.0856.03Cooling performance coefficient (EER)/5.115.045.135.125.025.195.215.135.15.125.06Rated heating capacityKWRated input power for heatingKW3.074.433.044.585.999.212.618.3922.0132.9543.73Rated input current for heatingA13.2719.175.668.5211.1517.123.4334.2140.9361.2981.33Heating performance coefficient (COP)/2.612.712.632.622.672.612.622.612.592.612.63Application side heat exchanger water flowM3/h1.382.061.382.062.754.135.688.269.814.7919.78Heat source side heat exchanger water flowM3/h1.722.581.722.583.445.167.110.3212.2618.4924.73Power supply1N 220V/50Hz (Special power supply for option)3N 380V/50Hz(Special power supply for option)CompressorTypeHermetic scroll typeQuantityPCSHeat source side heat exchangerTypeShell & coil(tube) heat exchangerConnection sizeDNDN20DN25DN25DN25DN25DN32DN32DN50DN65DN65DN80Application side heat exchangerTypeShell & coil(tube) heat exchangerConnection sizeDNDN20DN25DN25DN25DN25DN32DN32DN50DN65DN65DN80Protections1. High and low pressure protection, 2. Anti-freeze protection, 3. High temperature protection, 4. Overload protection, 5. Reverse of phase protection, Lack of phase protection, etc.RefrigerantTypeR410AQuantityKG2.63.32.63.34.23.3x24.2x26.6x27.6x27.6x37.6x4Dimensionmm790x415x590790x710x9502000x1000x1600Wooden case package dimensions(L*W*H)mm836x461x752836x756x11122056x1056x1768Net weightKGGross weightKGNoiseDB(A)≤53≤55≤55≤55≤58≤58≤62≤65≤70≤75≤75Note:1. Underground water open loop type cooling standard condition: application side water input/output temperature 12℃/7℃; source side water input/output temperature 18℃/29℃. Underground water open loop type heating standard condition: application side water input/output temperature 40℃/45℃; source side water input/output temperature 15℃/-a.2. Ground source closed loop type cooling standard condition: application side water input/output temperature 12℃/7℃; source side water input/output temperature 25℃/30℃ Ground source closed loop type heating standard condition: application side water input/output temperature 40℃/45℃ ; source side water input/output temperature 5℃/-a.3. "-a " means the water flow under cooling standard condition.The above parameters may have some differences from the final product because of products updating, so above information is not the provision of any business contract. Please refer to final product lable, or refer to us for any information. Our company keeps the right to interpret.


Отправить запрос, связаться с поставщиком

Кому: JIAXING MES NEW ENERGY TECHNOLOGY CO., LTD
Ваш E-mail:
Текст письма:


Send to other suppliers

Другие товары поставщика

Residential EVI low temperature air source heat pumps for house warming for lowest ambient temperature -25℃ area This is air source heat pump for h...
Commercial water source heat pumps for 70℃ hot water This is water source heat pumps for commercial hot water rated temperature 70℃, it is applicab...
Residential water source heat pumps for 70℃ hot water This is water source heat pump for residential hot water rated temperature 70℃, we only use t...
Residential water source heat pumps for 50℃ hot water This is water source heat pump for residential hot water rated temperature 50℃, we can use di...
Commercial air source heat pump for 50℃ hot water This is air source circulation type heat pump for commercial hot water rated temperature 50℃, Adj...
Все товары поставщика

Похожие товары

Плита 34# клапана форсунки Денсо с отверстием 34# дизельного топлива для инжектора Денсо
Плита 34# клапана форсунки Денсо с отверстием 34# дизельного топлива для инжектора Денсо Продавец: DIP (ДИЗЕЛЬНЫЕ ДЕТАЛИ) УСТАНОВКИ
0 414 287 011 Насос дизельного топливного агрегата 0414287011 для двигателя Deutz 1011
0 414 287 011 Насос дизельного топливного агрегата 0414287011 для двигателя Deutz 1011 Продавец: DIP (ДИЗЕЛЬНЫЕ ДЕТАЛИ) УСТАНОВКИ
Совершенно новая форсунка дизельного топлива 4359204 для двигателя Cummins QSL9.3
Совершенно новая форсунка дизельного топлива 4359204 для двигателя Cummins QSL9.3 Продавец: DIP (ДИЗЕЛЬНЫЕ ДЕТАЛИ) УСТАНОВКИ
Совершенно новый дизельный топливный насос 3095454 для двигателя Cummins K38
Совершенно новый дизельный топливный насос 3095454 для двигателя Cummins K38 Продавец: DIP (ДИЗЕЛЬНЫЕ ДЕТАЛИ) УСТАНОВКИ
0445110250 Форсунка дизельного топлива Common Rail 0 445 110 250 В наличии
0445110250 Форсунка дизельного топлива Common Rail 0 445 110 250 В наличии Продавец: DIP (ДИЗЕЛЬНЫЕ ДЕТАЛИ) УСТАНОВКИ