.

Commercial Water Source Heat Pumps For Cooling And Heating

Commercial water source heat pumps for cooling and heating This is water source heat pumps commercial use for cooling and heating,Website:, it is usually installed in area where weather very cold in winter, and in summer it can also supply chilled water for cooling.We only use the best quality and famous brand parts for assembling and all the testing for the heat pump parts and heat pump units will be finished by expert workers and engineers with professional equipment.Product Info.CompressorCopeland scroll or Panasonic scrollCapacity11KW,17KW,24KW,34KW,48KW,68KW,80KW,      120KW,160KWRefrigerantR410ACondenser"ND" shell and tube heat exchangerEvaporatorShell & tube, tube in tube or plate type heat exchangerAC contactor & RelaySchneiderElectronic expansion valveJapan Saginomiya or World No.1 SanhuaControllerLCDPackageWooden case or CartonFastenersStainless steel 304Additional Info. Delivery time25 days after order confirmedWarranty time24 months after shipmentPayment termT/T or L/C at sightProduction capacity400 units per monthBrandMES or OEMParameters Cooler-CW (Commercial Water source heat pump for cooling & heating) CL-CW-1609CL11s-CW5CL17s-CW5CL11-CW5CL17-CW5CL24-CW5CL34-CW10CL48-CW10CL68-CW20CL80-CW20CL120-CW20CL160-CW20Underground water open loopRated cooling capacityKWRated input power for coolingKW2.153.342.113.24.726.539.1813.1815.7223.3531.56Rated input current for coolingA9.5514.843.986.048.9112.3317.3524.9129.7144.1259.64Cooling performance coefficient (EER)/5.125.095.225.325.095.215.235.165.095.145.07Rated heating capacityKW9.5169.Rated input power for heatingKW2.594.382.594.316.098.8612.3318.0121.0132.3941.78Rated input current for heatingA12.3320.874.898.1511.5216.7523.334.0339.7161.2378.97Heating performance coefficient (COP)/3.673.653.673.713.613.613.653.613.573.553.59Application side heat exchanger water flowM3/h1.892.921.892.924.135.858.2611.713.7620.6427.52Heat source side heat exchanger water flowM3/h1.031.591.031.592.253.194.56.387.5111.2615.01Ground source closed loopRated cooling capacityKWRated input power for coolingKW1.963.171.953.134.386.178.8312.4814.922.2729.64Rated input current for coolingA8.714.113.685.918.2811.6516.6923.5828.1642.0856.03Cooling performance coefficient (EER)/5.115.045.135.125.025.195.215.135.15.125.06Rated heating capacityKWRated input power for heatingKW3.074.433.044.585.999.212.618.3922.0132.9543.73Rated input current for heatingA13.2719.175.668.5211.1517.123.4334.2140.9361.2981.33Heating performance coefficient (COP)/2.612.712.632.622.672.612.622.612.592.612.63Application side heat exchanger water flowM3/h1.382.061.382.062.754.135.688.269.814.7919.78Heat source side heat exchanger water flowM3/h1.722.581.722.583.445.167.110.3212.2618.4924.73Power supply1N 220V/50Hz (Special power supply for option)3N 380V/50Hz(Special power supply for option)CompressorTypeHermetic scroll typeQuantityPCSHeat source side heat exchangerTypeShell & coil(tube) heat exchangerConnection sizeDNDN20DN25DN25DN25DN25DN32DN32DN50DN65DN65DN80Application side heat exchangerTypeShell & coil(tube) heat exchangerConnection sizeDNDN20DN25DN25DN25DN25DN32DN32DN50DN65DN65DN80Protections1. High and low pressure protection, 2. Anti-freeze protection, 3. High temperature protection, 4. Overload protection, 5. Reverse of phase protection, Lack of phase protection, etc.RefrigerantTypeR410AQuantityKG2.63.32.63.34.23.3x24.2x26.6x27.6x27.6x37.6x4Dimensionmm790x415x590790x710x9502000x1000x1600Wooden case package dimensions(L*W*H)mm836x461x752836x756x11122056x1056x1768Net weightKGGross weightKGNoiseDB(A)≤53≤55≤55≤55≤58≤58≤62≤65≤70≤75≤75Note:1. Underground water open loop type cooling standard condition: application side water input/output temperature 12℃/7℃; source side water input/output temperature 18℃/29℃. Underground water open loop type heating standard condition: application side water input/output temperature 40℃/45℃; source side water input/output temperature 15℃/-a.2. Ground source closed loop type cooling standard condition: application side water input/output temperature 12℃/7℃; source side water input/output temperature 25℃/30℃ Ground source closed loop type heating standard condition: application side water input/output temperature 40℃/45℃ ; source side water input/output temperature 5℃/-a.3. "-a " means the water flow under cooling standard condition.The above parameters may have some differences from the final product because of products updating, so above information is not the provision of any business contract. Please refer to final product lable, or refer to us for any information. Our company keeps the right to interpret.


Send product request

To: JIAXING MES NEW ENERGY TECHNOLOGY CO., LTD
Your E-mail:
Message text:


Send to other suppliers

Other supplier products

Residential Water Source Heat Pumps For 50℃ Hot Water
Residential Water Source Heat Pumps For 50℃ Hot Water Residential water source heat pumps for 50℃ hot water This is water source heat pump for residential hot water rated temperature 50℃, we can use di...
Commercial Water Source Heat Pumps For 50℃ Hot Water
Commercial Water Source Heat Pumps For 50℃ Hot Water Commercial water source heat pumps for 50℃ hot water This is water source heat pumps for commercial hot water rated temperature 50℃, it is used wid...
Commercial Swimming Pool Heat Pump Water Heater
Commercial Swimming Pool Heat Pump Water Heater Commercial swimming pool heat pump water heater This is swimming pool heat pumps for pool heating but without cooling function,Website:, it is for ...
Residential Air Source Heat Pumps Split Type
Residential Air Source Heat Pumps Split Type Residential air source heat pumps split type This is split type heat pump for residential hot water, one heat pump for outdoor unit but without con...
Commercial Air Source Heat Pumps For Lowest Ambient Temperature -15℃ Area
Commercial Air Source Heat Pumps For Lowest Ambient Temperature -15℃ Area Commercial air source heat pumps for waraming forlowest ambient temperature -15℃ area This is air source heat pumps for commercial building warming...
All supplier products

Same products

Diesel Fuel Orifice Plate 34# Denso Injector Valve Plate 34# For Denso Injector
Diesel Fuel Orifice Plate 34# Denso Injector Valve Plate 34# For Denso Injector Seller: DIP (DIESEL INJECTION PARTS) PLANTS
0 414 287 011 Diesel Fuel Unit Pump 0414287011 for Deutz 1011 Engine
0 414 287 011 Diesel Fuel Unit Pump 0414287011 for Deutz 1011 Engine Seller: DIP (DIESEL INJECTION PARTS) PLANTS
Brand New Diesel Fuel Injector 4359204 For Cummins QSL9.3 Engine
Brand New Diesel Fuel Injector 4359204 For Cummins QSL9.3 Engine Seller: DIP (DIESEL INJECTION PARTS) PLANTS
Brand New Diesel Fuel Pump 3095454 for Cummins K38 Engine
Brand New Diesel Fuel Pump 3095454 for Cummins K38 Engine Seller: DIP (DIESEL INJECTION PARTS) PLANTS
0445110250 Injector Diesel Common Rail Fuel Injector 0 445 110 250 Available
0445110250 Injector Diesel Common Rail Fuel Injector 0 445 110 250 Available Seller: DIP (DIESEL INJECTION PARTS) PLANTS