Shielding hall of HV PD test

Shielding hall of HV PD test

Application:

HV test shielding room (faraday cage) areWidely used in power cable, transformer, transformer switch, transformer substation and other High voltage levels of partial discharge test or impulse test.

For HV testing shielding room, as a HV test place, it should has good electromagnetic

shielding condition. And its electromagnetic compatibility always is of great importance.

Firstly, it should restrict electromagnetic wave into inside shielding room caused by

discharge when making HV test to weakening interfere to outside, especially on

electronic and communication system. Secondly, it should prevent outer

electromagnetic wave intruding into shielding room to cause measurement error of

partial discharge and wireless. Thirdly, it should reduces open circuit voltage and

closed current to restrain common-mode interference so that to avoid equipment

damage and to improve accuracy of impulse measurement.

For GIS HV test shielding room, design area is 500 m2(Length 25m、Width 20m).

From provided information , we find that steel structure have been completed

already with one set of 20T crane indoor, crane supporting corbel also completed, the

height is 17.9m from ground to upper part of corbel. Main door height 13m,width 10m,

locates at downward of the west side, the door open direction towards to north .

According to ILJIN drawing, three side of structure column has already, but western

structure column still missing yet. however, as the main door will be located in this side,

the western side also should have steel structure , and this structure position still should

be unified considered with main door installation. We will be able to submit suggested

design diagram with position & size of this structure column for reference. in order to

save construction cost, the construction engineering will be carried out by ILJIN

Technical Specification

 Shielding efficiency 0.15 MHz~1.6MHz≥60dB

 reverberation time <5S(at 400Hz 400Hz )

 Background noise level (Ambient level) <5Pc

 Grounding resistance :≤0.5Ω

Background noise can be promised to be not more than 5Pc if no-load equipment

without voltage. (this is what we should to ensure).

 Under equipment running condition ( applied voltage on equipment), user

should check on the whole testing system. such as whether power frequency

testing transformer meets with ambient requirements or not? whether if power

supply has been treated well or not? Whether surrounding other equipment are

placed too close to cause interference or not? And so on. To be honest, And it

seems not directly relevant to background noise level of shielding room .


Отправить запрос, связаться с поставщиком

Кому: CNME Intermational Co.Ltd
Ваш E-mail:
Текст письма:


Send to other suppliers

Другие товары поставщика

Transformer Plant Design
Transformer Plant Design Transformer Plant Design We will be willing to provide whole-process engineering consulting servicesfor you: Preparingfeasibility study reportor Pr...
500kV Mobile Lab for CT/VT measurement test
500kV Mobile Lab for CT/VT measurement test 500kV Mobile Lab for CT/VT measurement test 500kVCT&PTmobile labis made up ofa truck for 220kV CT&PT error test, a 500kV van-typetrailer,te...
Mobile substation
Mobile substation Mobile substation Performance characteristics ① Rapid allocation: connections between equipments are connected .After connected to earth system and...
Shuttle kiln for ceramic products
Shuttle kiln for ceramic products Shuttle kiln for ceramic products Brief introduction of shuttle kiln: shuttle kilnandtunnelkilnare important sintering equipment in ceramic and pro...
Digital partical discharge detector
Digital partical discharge detector Digital partical discharge detector Features ²ØWith anti-interference mode, which is unique in China, so that to attenuate space interf...
Все товары поставщика

Похожие товары

Amorphous Alloy Type Transformer Iron Core
Amorphous Alloy Type Transformer Iron Core Продавец: Shijiazhuang Tianya Electric Co., LTD Amorphous Alloy Type Transformer Iron Core -The iron coreis made of high magnetic conductivity m...
10kv Dry Type Epoxy Resin Cast Power Transformer
10kv Dry Type Epoxy Resin Cast Power Transformer Продавец: Shijiazhuang Tianya Electric Co., LTD 10kv Dry Type Epoxy Resin Cast Power Transformer Epoxy resin cast dry-type transformeris a high-...
HM B200/B210 Series
HM B200/B210 Series Продавец: BEIJING HIGHMESH INFORMATION TECHNOLOGY CO.,LTD. HM B200/B210 Series USRP B200/B210 Product Overview The B200 and B210 hardwarecovers RF frequen...
HM-B210(Single-Board)
HM-B210(Single-Board) Продавец: BEIJING HIGHMESH INFORMATION TECHNOLOGY CO.,LTD. HM-B210(Single-Board) Description TheB210is a highly integrated Universal Software Radio Periph...
Busbar systems
Busbar systems Продавец: Jinan Dema Electric Co., Ltd. Busbar systems Busbar Systems for Plant Reliable Industrial Power Distribution Solutions for Fa...